Historical snapshot · Cybersecurity

CISA Advisories

Cybersecurity advisories and mitigation guidance for networks and critical infrastructure.

This page is an archived snapshot of the CISA Advisories feed collected on Jun 15, 2026, preserved by BioThreat Corporation. Publication dates belong to the original source; this snapshot is not a current advisory.
30 recordsOfficial source · JSON
· CISA Cybersecurity Advisory

CISA Adds One Known Exploited Vulnerability to Catalog

CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-0257 Palo Alto Networks PAN-OS Authentication Bypass Vulnerability This type of vulnerability is a frequent attack vectors for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk…
Read full source summary
CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-0257 Palo Alto Networks PAN-OS Authentication Bypass Vulnerability This type of vulnerability is a frequent attack vectors for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the BOD 22-01 Fact Sheet for more information. Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of KEV Catalog vulnerabilities as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the specified criteria.
· CISA Cybersecurity Advisory

Jinan USR IOT Technology Limited (PUSR) USR-W610 RS232/485 to Wi-Fi/Ethernet Converter

View CSAF Summary Successful exploitation of this vulnerability could result in an attacker gaining administrator access to the device. The following versions of Jinan USR IOT Technology Limited (PUSR) USR-W610 RS232/485 to Wi-Fi/Ethernet Converter are affected: USR-W610 RS232/485 to Wi-Fi/Ethernet Converter 7.03T.07 CVSS Vendor Equipment Vulnerabilities v3 9.8 Jinan USR IOT Technology Limited (PUSR) Jinan USR IOT…
Read full source summary
View CSAF Summary Successful exploitation of this vulnerability could result in an attacker gaining administrator access to the device. The following versions of Jinan USR IOT Technology Limited (PUSR) USR-W610 RS232/485 to Wi-Fi/Ethernet Converter are affected: USR-W610 RS232/485 to Wi-Fi/Ethernet Converter 7.03T.07 CVSS Vendor Equipment Vulnerabilities v3 9.8 Jinan USR IOT Technology Limited (PUSR) Jinan USR IOT Technology Limited (PUSR) USR-W610 RS232/485 to Wi-Fi/Ethernet Converter Use of Hard-coded Credentials Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: China Vulnerabilities Expand All + CVE-2026-7786 The device firmware contains plaintext administrative credentials embedded in the firmware image. These credentials can be extracted through firmware analysis and used to authenticate to device services. View CVE Details Affected Products Jinan USR IOT Technology Limited (PUSR) USR-W610 RS232/485 to Wi-Fi/Ethernet Converter Vendor: Jinan USR IOT Technology Limited (PUSR) Product Version: Jinan USR IOT Technology Limited (PUSR) USR-W610 RS232/485 to Wi-Fi/Ethernet Converter: 7.03T.07 Product Status: known_affected Remediations Mitigation Jinan USR IOT Technology Limited (PUSR) did not respond to CISA's attempts at coordination. Users of PUSR USR-W610 devices are encouraged to contact PUSR and keep their systems up to date. Relevant CWE: CWE-798 Use of Hard-coded Credentials Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.8 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H Acknowledgments Arun Mane and Omkar Mali reported this vulnerability to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. Revision History Initial Release Date: 2026-05-28 Date Revision Summary 2026-05-28 1 Initial Publication Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

MacGregor Voyage Data Recorder (VDR) G4e

View CSAF Summary Successful exploitation of these vulnerabilities could result in an attacker gaining administrator access to the device. The following versions of MacGregor Voyage Data Recorder (VDR) G4e are affected: MacGregor Voyage Data Recorder (VDR) G4e <V5.250 CVSS Vendor Equipment Vulnerabilities v3 8.3 Danelec MacGregor Voyage Data Recorder (VDR) G4e Use of Default Credentials, Insufficiently Protected…
Read full source summary
View CSAF Summary Successful exploitation of these vulnerabilities could result in an attacker gaining administrator access to the device. The following versions of MacGregor Voyage Data Recorder (VDR) G4e are affected: MacGregor Voyage Data Recorder (VDR) G4e <V5.250 CVSS Vendor Equipment Vulnerabilities v3 8.3 Danelec MacGregor Voyage Data Recorder (VDR) G4e Use of Default Credentials, Insufficiently Protected Credentials, Use of Password Hash With Insufficient Computational Effort, Use of Hard-coded Credentials, Files or Directories Accessible to External Parties Background Critical Infrastructure Sectors: Transportation Systems Countries/Areas Deployed: Worldwide Company Headquarters Location: Denmark Vulnerabilities Expand All + CVE-2026-42941 The VDR device includes a default username and password, with no enforced password change. View CVE Details Affected Products MacGregor Voyage Data Recorder (VDR) G4e Vendor: Danelec Product Version: Danelec MacGregor Voyage Data Recorder (VDR) G4e: <V5.250 Product Status: known_affected Remediations Vendor fix Danelec has released firmware version V5.250 to resolve these vulnerabilities. Users of MacGregor Voyage Data Recorder (VDR) G4e devices are encouraged to update the firmware at the earliest service attendance rather than waiting for an annual performance test. Contact Danelec with additional questions: https://www.danelec.com/contact https://www.danelec.com/contact Relevant CWE: CWE-1392 Use of Default Credentials Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.3 HIGH CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:L 4.0 8.7 HIGH CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:L/SC:N/SI:N/SA:N CVE-2026-42951 An authenticated user can download a backup of the device which includes account data and password hashes. View CVE Details Affected Products MacGregor Voyage Data Recorder (VDR) G4e Vendor: Danelec Product Version: Danelec MacGregor Voyage Data Recorder (VDR) G4e: <V5.250 Product Status: known_affected Remediations Vendor fix Danelec has released firmware version V5.250 to resolve these vulnerabilities. Users of MacGregor Voyage Data Recorder (VDR) G4e devices are encouraged to update the firmware at the earliest service attendance rather than waiting for an annual performance test. Contact Danelec with additional questions: https://www.danelec.com/contact https://www.danelec.com/contact Relevant CWE: CWE-522 Insufficiently Protected Credentials Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.4 MEDIUM CVSS:3.1/AV:A/AC:H/PR:L/UI:N/S:U/C:H/I:L/A:N 4.0 5.9 MEDIUM CVSS:4.0/AV:A/AC:H/AT:N/PR:L/UI:N/VC:H/VI:L/VA:N/SC:N/SI:N/SA:N CVE-2026-44611 Passwords are stored with a hashing method which limits password length and is susceptible to brute force attacks. View CVE Details Affected Products MacGregor Voyage Data Recorder (VDR) G4e Vendor: Danelec Product Version: Danelec MacGregor Voyage Data Recorder (VDR) G4e: <V5.250 Product Status: known_affected Remediations Vendor fix Danelec has released firmware version V5.250 to resolve these vulnerabilities. Users of MacGregor Voyage Data Recorder (VDR) G4e devices are encouraged to update the firmware at the earliest service attendance rather than waiting for an annual performance test. Contact Danelec with additional questions: https://www.danelec.com/contact https://www.danelec.com/contact Relevant CWE: CWE-916 Use of Password Hash With Insufficient Computational Effort Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.4 MEDIUM CVSS:3.1/AV:A/AC:H/PR:L/UI:N/S:U/C:H/I:L/A:N 4.0 5.9 MEDIUM CVSS:4.0/AV:A/AC:H/AT:N/PR:L/UI:N/VC:H/VI:L/VA:N/SC:N/SI:N/SA:N CVE-2026-42929 The device includes default accounts with hard-coded credentials. View CVE Details Affected Products MacGregor Voyage Data Recorder (VDR) G4e Vendor: Danelec Product Version: Danelec MacGregor Voyage Data Recorder (VDR) G4e: <V5.250 Product Status: known_affected Remediations Vendor fix Danelec has released firmware version V5.250 to resolve these vulnerabilities. Users of MacGregor Voyage Data Recorder (VDR) G4e devices are encouraged to update the firmware at the earliest service attendance rather than waiting for an annual performance test. Contact Danelec with additional questions: https://www.danelec.com/contact https://www.danelec.com/contact Relevant CWE: CWE-798 Use of Hard-coded Credentials Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.3 HIGH CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:L 4.0 8.7 HIGH CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:L/SC:N/SI:N/SA:N CVE-2026-40425 The administrator account for the web interface can directly edit sensitive files related to authentication, potentially changing the root password. View CVE Details Affected Products MacGregor Voyage Data Recorder (VDR) G4e Vendor: Danelec Product Version: Danelec MacGregor Voyage Data Recorder (VDR) G4e: <V5.250 Product Status: known_affected Remediations Vendor fix Danelec has released firmware version V5.250 to resolve these vulnerabilities. Users of MacGregor Voyage Data Recorder (VDR) G4e devices are encouraged to update the firmware at the earliest service attendance rather than waiting for an annual performance test. Contact Danelec with additional questions: https://www.danelec.com/contact https://www.danelec.com/contact Relevant CWE: CWE-552 Files or Directories Accessible to External Parties Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.7 MEDIUM CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:L/A:L 4.0 6.9 MEDIUM CVSS:4.0/AV:A/AC:L/AT:N/PR:H/UI:N/VC:H/VI:L/VA:L/SC:N/SI:N/SA:N Acknowledgments Andrew Tierney of Pen Test Partners reported these vulnerabilities to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. Revision History Initial Release Date: 2026-05-28 Date Revision Summary 2026-05-28 1 Initial Publication Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

KMW CCTV Security Cameras

View CSAF Summary Successful exploitation of this vulnerability may grant full unauthorized access to camera feeds and settings. The following versions of KMW CCTV Security Cameras are affected: KM-IP521 IPCAM_V4.04.91.230307 KM-IP421 IPCAM_V4.04.53.210416 CVSS Vendor Equipment Vulnerabilities v3 9.1 KMW KMW CCTV Security Cameras Unverified Password Change Background Critical Infrastructure Sectors: Commercial…
Read full source summary
View CSAF Summary Successful exploitation of this vulnerability may grant full unauthorized access to camera feeds and settings. The following versions of KMW CCTV Security Cameras are affected: KM-IP521 IPCAM_V4.04.91.230307 KM-IP421 IPCAM_V4.04.53.210416 CVSS Vendor Equipment Vulnerabilities v3 9.1 KMW KMW CCTV Security Cameras Unverified Password Change Background Critical Infrastructure Sectors: Commercial Facilities, Government Services and Facilities, Critical Manufacturing, Financial Services, Transportation Systems Countries/Areas Deployed: Worldwide Company Headquarters Location: Romania Vulnerabilities Expand All + CVE-2026-5386 The affected product is vulnerable to a critical unauthenticated password reset. This flaw allows an attacker to remotely reset the administrator password to a known value without authentication, granting full access to the camera feeds and settings. View CVE Details Affected Products KMW CCTV Security Cameras Vendor: KMW Product Version: KMW KM-IP521: IPCAM_V4.04.91.230307, KMW KM-IP421: IPCAM_V4.04.53.210416 Product Status: known_affected Remediations Mitigation KMW has issued a firmware update to address this vulnerability. The firmware update can be found at https://main.kmw.ro/pub/Firmware/521_421.zip. https://main.kmw.ro/pub/Firmware/521_421.zip Vendor fix KM-IP421 - will lose the cloud authorization after this update so users will need to contact customer support to re-authorize the P2P connection. Mitigation KMW recommends connecting surveillance equipment on a separate network, allow only specific devices access to the internet, check for firmware updates regularly, and use cloud connections responsibly. Mitigation If there are any issues customers are encouraged to contact KMW directly. Relevant CWE: CWE-620 Unverified Password Change Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.1 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N Acknowledgments Reporter Name(s): Souvik Kandar reported this vulnerability to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. Revision History Initial Release Date: 2026-05-28 Date Revision Summary 2026-05-28 1 Initial Publication Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

XCharge C6

View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to gain administrator rights or execute code on the affected device. The following versions of XCharge C6 are affected: C6 CVSS Vendor Equipment Vulnerabilities v3 9.8 XCharge XCharge C6 Download of Code Without Integrity Check, Stack-based Buffer Overflow, Initialization of a Resource with an Insecure Default Background…
Read full source summary
View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to gain administrator rights or execute code on the affected device. The following versions of XCharge C6 are affected: C6 CVSS Vendor Equipment Vulnerabilities v3 9.8 XCharge XCharge C6 Download of Code Without Integrity Check, Stack-based Buffer Overflow, Initialization of a Resource with an Insecure Default Background Critical Infrastructure Sectors: Transportation Systems Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2026-9037 A firmware update mechanism in the affected charging controller fails to validate the authenticity of firmware packages delivered through the device's management interface. Because cryptographic signatures are not verified, an attacker with the ability to interfere with or impersonate the management channel could cause the device to install an unauthorized firmware package. This condition could allow execution of unauthorized code with high privileges on the device, View CVE Details Affected Products XCharge C6 Vendor: XCharge Product Version: XCharge C6: <May_22_2026 Product Status: known_affected Remediations Mitigation XCharge has confirmed that the update has been deployed for all affected chargers. Users with questions can reach out to XCharge Support for further details if needed. https://www.xcharge.com/contact https://www.xcharge.com/contact Relevant CWE: CWE-494 Download of Code Without Integrity Check Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.8 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H CVE-2026-9038 A stack-based buffer overflow vulnerability in the charging controller's signal-processing logic allows an attacker with physical access to the charging interface to supply message fields that exceed expected bounds. Because the input is not sufficiently validated, memory corruption may occur, which can lead to execution of unauthorized code with elevated privileges. View CVE Details Affected Products XCharge C6 Vendor: XCharge Product Version: XCharge C6: <May_22_2026 Product Status: known_affected Remediations Mitigation XCharge has confirmed that the update has been deployed for all affected chargers. Users with questions can reach out to XCharge Support for further details if needed. https://www.xcharge.com/contact https://www.xcharge.com/contact Relevant CWE: CWE-121 Stack-based Buffer Overflow Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.6 HIGH CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H CVE-2026-9039 A configuration weakness in the device's remote management service allows an authenticated session to be established over a communication channel intended solely for vehicle-charger signaling. The service is accessible on interfaces exposed through the charging connector, and it accepts a default administrative credential. A malicious device physically connected to the charging interface could leverage this misconfiguration to obtain full administrative access. View CVE Details Affected Products XCharge C6 Vendor: XCharge Product Version: XCharge C6: <May_22_2026 Product Status: known_affected Remediations Mitigation XCharge has confirmed that the update has been deployed for all affected chargers. Users with questions can reach out to XCharge Support for further details if needed. https://www.xcharge.com/contact https://www.xcharge.com/contact Relevant CWE: CWE-1188 Initialization of a Resource with an Insecure Default Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.6 HIGH CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H Acknowledgments Lionel R. Saposnik of SaiFlow reported these vulnerabilities to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. Revision History Initial Release Date: 2026-05-28 Date Revision Summary 2026-05-28 1 Initial Publication Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

ABB Busch-Welcome 2 Wire Door Opener Actuator

View CSAF Summary ABB is aware of vulnerabilities in the product versions listed as affected in the advisory. An attacker who successfully exploited this vulnerability could gain physical, unauthorized access to a Building where the product is installed The following versions of ABB Busch-Welcome 2 Wire Door Opener Actuator are affected: Switch Actuator 4 DU vers:all/* Switch actuator, door/light 4 DU vers:all/*…
Read full source summary
View CSAF Summary ABB is aware of vulnerabilities in the product versions listed as affected in the advisory. An attacker who successfully exploited this vulnerability could gain physical, unauthorized access to a Building where the product is installed The following versions of ABB Busch-Welcome 2 Wire Door Opener Actuator are affected: Switch Actuator 4 DU vers:all/* Switch actuator, door/light 4 DU vers:all/* CVSS Vendor Equipment Vulnerabilities v3 6.8 ABB ABB Busch-Welcome 2 Wire Door Opener Actuator Active Debug Code Background Critical Infrastructure Sectors: Commercial Facilities Countries/Areas Deployed: Worldwide Company Headquarters Location: Switzerland Vulnerabilities Expand All + CVE-2025-7705 Authentication bypass due to compatibility mode enabled by default View CVE Details Affected Products ABB Busch-Welcome 2 Wire Door Opener Actuator Vendor: ABB Product Version: Switch Actuator 4 DU -83330 - All Versions, Switch actuator, door/light 4 DU -83330-500 - All Versions Product Status: known_affected Remediations Mitigation The following actions need to be executed on premise where the respective Busch-Welcome® System is installed: • While the Busch-Welcome® System is in operation, toggle the mode switch on the product from “Door-Open” - to “Light” – Mode, wait one second and switch back to “Door-Open” - Mode. • Restart the Busch-Welcome® System with a Power reset (mains power off and on again). By executing the above steps, the system will recalibrate itself during boot up and will correct the misconfiguration automatically. ABB recommends that customers apply the above listed actions at the earliest convenience. Relevant CWE: CWE-489 Active Debug Code Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.8 MEDIUM CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H Acknowledgments ABB PSIRT reported this vulnerability to CISA. Notice The information in this document is subject to change without notice, and should not be construed as a commitment by ABB. ABB provides no warranty, express or implied, including warranties of merchantability and fitness for a particular purpose, for the information contained in this document, and assumes no responsibility for any errors that may appear in this document. In no event shall ABB or any of its suppliers be liable for direct, indirect, special, incidental or consequential damages of any nature or kind arising from the use of this document, or from the use of any hard-ware or software described in this document, even if ABB or its suppliers have been advised of the possibility of such damages. This document and parts hereof must not be reproduced or copied without written permission from ABB, and the contents hereof must not be imparted to a third party nor used for any unauthorized purpose. All rights to registrations and trademarks reside with their respective owners. Mitigating factors ABB recommends double check the system handbook of a Busch-Welcome® two wire system regarding security advises for the correct installation. Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of ABB PSIRT 9AKK108471A4556 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact ABB PSIRT directly for any questions regarding this advisory. Revision History Initial Release Date: 2025-07-21 Date Revision Summary 2025-07-21 1 Initial version. 2026-05-28 2 Initial CISA Republication of ABB PSIRT 9AKK108471A4556 advisory Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Supply Chain Compromises Impact Nx Console and GitHub Repositories

CISA is prioritizing the response to multiple emerging software supply chain intrusion campaigns targeting developer ecosystems Continuous Integration/Continuous Development (CI/CD) pipelines. These recent incidents, including the GitHub compromise via a malicious Nx Console Visual Studio Code (VS Code) extension and the “Megalodon” supply chain intrusion campaign, demonstrate how cyber threat actors are abusing…
Read full source summary
CISA is prioritizing the response to multiple emerging software supply chain intrusion campaigns targeting developer ecosystems Continuous Integration/Continuous Development (CI/CD) pipelines. These recent incidents, including the GitHub compromise via a malicious Nx Console Visual Studio Code (VS Code) extension and the “Megalodon” supply chain intrusion campaign, demonstrate how cyber threat actors are abusing tools and processes that support enterprise, cloud, and DevOps environments—specifically CI/CD pipelines, code extensions and workflows. Threat actors leveraged a prior compromise of Nx developer systems to compromise a GitHub employee’s device through a poisoned third-party VS Code extension, resulting in unauthorized access and exfiltration of internal GitHub repositories. The malicious extension version (18.95.0) was distributed through VS Code’s automatic update mechanism, meaning systems with Nx Console previously installed may have received the malicious build without developers taking any manual installation action. GitHub released a security advisory on this activity, and CVE-2026-48027 has been assigned to the malicious version of Nx Console and added to CISA’s Known Exploited Vulnerabilities (KEV) Catalog. Additionally, in a campaign known as “Megalodon,” a cyber threat actor injected malicious GitHub Action workflows to harvest CI/CD secrets, cloud credentials, and tokens, impacting both development and deployment pipelines in public GitHub repositories. CISA urges organizations to implement the following recommendations to detect and remediate a potential compromise: Monitor and audit workflow files and contributor activity for suspicious pull requests and direct commits, particularly those authored by automated accounts. Revert unauthorized changes, especially from automated accounts, e.g., build-bot, auto-ci, ci-bot, pipeline-bot and especially those made after May 18, 2026. If your organization discovers a compromise resulting from previously compromised GitHub or Nx Console software, CISA recommends the following steps: Conduct a forensics review of CI/CD logs, cloud audit trails, and affected developer machines. Rotate/revoke all secrets including: all credentials, tokens, and secrets accessible to CI/CD pipelines, including API keys, cloud provider credentials (Amazon Web Services, Google Cloud Platform, Microsoft Azure), SSH keys, Docker/npm/PyPI/Vault/Terraform/Kubernetes tokens, GitHub/GitLab/Bitbucket tokens, and developer or pipeline secrets. Notify proper stakeholders if necessary. CISA recommends the following best practices for using package repos: Wait at least three hours before pulling a new package. This gives the software community time to identify suspicious or malicious packages before they are widely downloaded. Pin software to specific trusted versions. Pinning software prevents pulling a malicious or unscreened package during the build process. Only pull packages from known and trusted sources. Relying on known and trusted sources reduces the likelihood of downloading a package that has been maliciously forked. See the following resources for additional guidance on these compromises: GitHub: Investigating unauthorized access to GitHub-owned repositories Nx: Postmortem: Nx Console v18.95.0 supply-chain compromise Ox Security: Megalodon: CI/CD Malware Spreading Across GitHub Repositories StepSecurity: Nx Console VS Code Extension Compromised SafeDep: Megalodon: Mass GitHub Repo Backdooring via CI Workflows Disclaimer The information in this report is being provided “as is” for informational purposes only. CISA does not endorse any commercial entity, product, company, or service, including any entities, products, or services linked within this document. Any reference to specific commercial entities, products, processes, or services by service mark, trademark, manufacturer, or otherwise, does not constitute or imply endorsement, recommendation, or favoring by CISA.
· CISA Cybersecurity Advisory

CP Plus 8 Ch. Network Video Recorder

View CSAF Summary Successful exploitation of this vulnerability allows an attacker's malicious script to execute in the browser of any authenticated user or administrator who accesses the affected interface. This could lead to compromise of user sessions, execution of unauthorized actions with the victim's privileges, exposure or manipulation of sensitive data, and degradation of overall system integrity. The…
Read full source summary
View CSAF Summary Successful exploitation of this vulnerability allows an attacker's malicious script to execute in the browser of any authenticated user or administrator who accesses the affected interface. This could lead to compromise of user sessions, execution of unauthorized actions with the victim's privileges, exposure or manipulation of sensitive data, and degradation of overall system integrity. The following versions of CP Plus 8 Ch. Network Video Recorder are affected: CP-UNR-108F1 Hardware V1.0 CP-UNR-108F1 Web V3.2.7.128806 CP-UNR-108F1 System V4.001.00AT009.0.R CVSS Vendor Equipment Vulnerabilities v3 8.4 CP Plus CP Plus 8 Ch. Network Video Recorder Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') Background Critical Infrastructure Sectors: Commercial Facilities, Critical Manufacturing, Emergency Services Countries/Areas Deployed: India, Nepal, United Arab Emirates, Gambia Company Headquarters Location: India Vulnerabilities Expand All + CVE-2026-6824 A stored Cross-Site Scripting (XSS) vulnerability exists in certain 1xxx series NVR devices due to insufficient sanitization of user-supplied input in specific functional modules. Attackers can inject malicious scripts, which are then persistently stored on the device backend. When administrators or users access affected pages, the stored scripts are executed in their browsers, leading to potential session hijacking, unauthorized actions, or data theft. View CVE Details Affected Products CP Plus 8 Ch. Network Video Recorder Vendor: CP Plus Product Version: CP Plus CP-UNR-108F1 Hardware: V1.0, CP Plus CP-UNR-108F1 Web: V3.2.7.128806, CP Plus CP-UNR-108F1 System: V4.001.00AT009.0.R Product Status: known_affected Remediations Mitigation CP Plus recommends updating the firmware on the device to the latest firmware version. Mitigation CP-UNR-AxxxMars_PN_15_Q_00_V1.00.14.01.T.260326 which can be downloaded at https://drive.google.com/file/d/1Ctxdp55UtlrQY7CSepkImM9zFgdcuCyL/view https://drive.google.com/file/d/1Ctxdp55UtlrQY7CSepkImM9zFgdcuCyL/view Mitigation For firmware access and upgrade instructions, please contact support at: Mitigation Phone: +91-8800952952 Mitigation Email: support@cpplusworld.com mailto:support@cpplusworld.com Relevant CWE: CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.4 HIGH CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:H/I:H/A:H Acknowledgments Jithin Nambiar J reported this vulnerability to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. Revision History Initial Release Date: 2026-05-28 Date Revision Summary 2026-05-28 1 Initial Publication Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Fourth Frontier Frontier X Mobile Application, Frontier X2

View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to read and write arbitrary handle values and change clinical readings, which could result in taking control of the device and lead to patient harm. The following versions of Fourth Frontier Frontier X Mobile Application, Frontier X2 are affected: Frontier X Android application vers<v15.0.0 Frontier X IOS application vers<v25.0.0…
Read full source summary
View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to read and write arbitrary handle values and change clinical readings, which could result in taking control of the device and lead to patient harm. The following versions of Fourth Frontier Frontier X Mobile Application, Frontier X2 are affected: Frontier X Android application vers<v15.0.0 Frontier X IOS application vers<v25.0.0 Frontier X2 vers:all/* CVSS Vendor Equipment Vulnerabilities v3 8.8 Fourth Frontier Fourth Frontier Frontier X Mobile Application, Frontier X2 Missing Authentication for Critical Function Background Critical Infrastructure Sectors: Healthcare and Public Health Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2026-5768 The Frontier X2 device allows unauthenticated BLE read/write access to critical GATT characteristics without enforcing pairing authentication or authorization. This allows attackers within BLE range to perform unauthorized control of device functions, including starting/stopping activities, triggering vibrations, causing denial-of-service conditions, and fuzzing characteristic values to induce unexpected behavior. Additionally, the Frontier X mobile application lacks proper BLE device authentication, allowing attackers to impersonate a legitimate Frontier X2 device and connect to the application. By cloning BLE advertisements and exposing expected GATT characteristics, attackers can manipulate activity states and inject fabricated health telemetry such as breathing rate, heart rate, strain, and other health-related data into the mobile application. View CVE Details Affected Products Fourth Frontier Frontier X Mobile Application, Frontier X2 Vendor: Fourth Frontier Product Version: Fourth Frontier Frontier X Android application: <v15.0.0, Fourth Frontier Frontier X IOS application: <v25.0.0, Fourth Frontier Frontier X2: vers:all/* Product Status: known_affected Remediations Mitigation Fourth Frontier is aware of the vulnerability and is working on a fix. Users are encouraged to reach out to Fourth Frontier directly for assistance. https://fourthfrontier.com/pages/contact-usl. https://fourthfrontier.com/pages/contact-us Mitigation Frontier X/X2 devices can connect to only one app at a time; users should first connect the Frontier X/X2 device using the Frontier X app and then start the activity. Relevant CWE: CWE-306 Missing Authentication for Critical Function Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.8 HIGH CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H Acknowledgments Shakir Zari and Jerin Sunny reported this vulnerability to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. This vulnerability is not exploitable remotely. Revision History Initial Release Date: 2026-05-28 Date Revision Summary 2026-05-28 1 Initial Publication Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Schneider Electric EcoStruxure Machine Expert HVAC

View CSAF Summary Schneider Electric is aware of a vulnerability in its EcostruxureTM Machine Expert HVAC product. The [EcostruxureTM Machine Expert HVAC](https://www.se.com/ww/en/download/document/EcoStruxureME_HVAC/) product is a programming software for Modicon M171-M172 logic controllers. Failure to apply the remediation provided below may risk in revealing sensitive information, which could result in disclosing…
Read full source summary
View CSAF Summary Schneider Electric is aware of a vulnerability in its EcostruxureTM Machine Expert HVAC product. The [EcostruxureTM Machine Expert HVAC](https://www.se.com/ww/en/download/document/EcoStruxureME_HVAC/) product is a programming software for Modicon M171-M172 logic controllers. Failure to apply the remediation provided below may risk in revealing sensitive information, which could result in disclosing protected source code, leading to loss of confidentiality. The following versions of Schneider Electric EcoStruxure Machine Expert HVAC (SEVD-2026-132-01) are affected: Ecostruxure™ Machine Expert HVAC vers<1.10.0 CVSS Vendor Equipment Vulnerabilities v3 5.5 Schneider Electric Schneider Electric EcoStruxure Machine Expert HVAC (SEVD-2026-132-01) Cleartext Storage of Sensitive Information Background Critical Infrastructure Sectors: Chemical, Critical Manufacturing, Energy, Water and Wastewater Countries/Areas Deployed: Worldwide Company Headquarters Location: France Vulnerabilities Expand All + CVE-2026-6332 CWE-312: Cleartext Storage of Sensitive Information vulnerability exists that could cause the disclosure of a sensitive information which could result in revealing protected source code and loss of confidentiality, when an authorized attacker accesses the source code for editing or compiling it. View CVE Details Affected Products Schneider Electric EcoStruxure Machine Expert HVAC (SEVD-2026-132-01) Vendor: Schneider Electric Product Version: Ecostruxure™ Machine Expert HVAC Versions prior to 1.10.0 Product Status: fixed, known_affected Remediations Vendor fix Version 1.10.0 of Ecostruxure™ Machine Expert HVAC includes a fix for this vulnerability and is available for download here: https://www.se.com/ww/en/download/document/EcoStruxureME_HVAC_1_10_0/ https://www.se.com/ww/en/download/document/EcoStruxureME_HVAC_1_10_0/ Relevant CWE: CWE-312 Cleartext Storage of Sensitive Information Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.5 MEDIUM CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N Acknowledgments Schneider Electric CPCERT reported this vulnerability to CISA. General Security Recommendations We strongly recommend the following industry cybersecurity best practices. * Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network. * Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks. * Place all controllers in locked cabinets and never leave them in the “Program” mode. * Never connect programming software to any network other than the network intended for that device. * Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks. * Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation. * Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet. * When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices. For more information refer to the Schneider Electric [Recommended Cybersecurity Best Practices](https://www.se.com/us/en/download/document/7EN52-0390/) document. For More Information This document provides an overview of the identified vulnerability or vulnerabilities and actions required to mitigate. For more details and assistance on how to protect your installation, contact your local Schneider Electric representative or Schneider Electric Industrial Cybersecurity Services: https://www.se.com/ww/en/work/solutions/cybersecurity/. These organizations will be fully aware of this situation and can support you through the process. For further information related to cybersecurity in Schneider Electric's products, visit the company's cybersecurity support portal page: https://www.se.com/ww/en/work/support/cybersecurity/overview.jsp LEGAL DISCLAIMER THIS NOTIFICATION DOCUMENT, THE INFORMATION CONTAINED HEREIN, AND ANY MATERIALS LINKED FROM IT (COLLECTIVELY, THIS “NOTIFICATION”) ARE INTENDED TO HELP PROVIDE AN OVERVIEW OF THE IDENTIFIED SITUATION AND SUGGESTED MITIGATION ACTIONS, REMEDIATION, FIX, AND/OR GENERAL SECURITY RECOMMENDATIONS AND IS PROVIDED ON AN “AS-IS” BASIS WITHOUT WARRANTY OR GUARANTEE OF ANY KIND. SCHNEIDER ELECTRIC DISCLAIMS ALL WARRANTIES RELATING TO THIS NOTIFICATION, EITHER EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. SCHNEIDER ELECTRIC MAKES NO WARRANTY THAT THE NOTIFICATION WILL RESOLVE THE IDENTIFIED SITUATION. IN NO EVENT SHALL SCHNEIDER ELECTRIC BE LIABLE FOR ANY DAMAGES OR LOSSES WHATSOEVER IN CONNECTION WITH THIS NOTIFICATION, INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF SCHNEIDER ELECTRIC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. YOUR USE OF THIS NOTIFICATION IS AT YOUR OWN RISK, AND YOU ARE SOLELY LIABLE FOR ANY DAMAGES TO YOUR SYSTEMS OR ASSETS OR OTHER LOSSES THAT MAY RESULT FROM YOUR USE OF THIS NOTIFICATION. SCHNEIDER ELECTRIC RESERVES THE RIGHT TO UPDATE OR CHANGE THIS NOTIFICATION AT ANY TIME AND IN ITS SOLE DISCRETION About Schneider Electric Schneider's purpose is to create Impact by empowering all to make the most of our energy and resources, bridging progress and sustainability for all. We call this Life Is On. Our mission is to be the trusted partner in Sustainability and Efficiency. We are a global industrial technology leader bringing world-leading expertise in electrification, automation and digitization to smart industries, resilient infrastructure, future-proof data centers, intelligent buildings, and intuitive homes. Anchored by our deep domain expertise, we provide integrated end-to-end lifecycle AI enabled Industrial IoT solutions with connected products, automation, software and services, delivering digital twins to enable profitable growth for our customers. We are a people company with an ecosystem of 150,000 colleagues and more than a million partners operating in over 100 countries to ensure proximity to our customers and stakeholders. We embrace diversity and inclusion in everything we do, guided by our meaningful purpose of a sustainable future for all. www.se.com Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Schneider Electric CPCERT SEVD-2026-132-01 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Schneider Electric CPCERT directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-05-12 Date Revision Summary 2026-05-12 1 Original Release 2026-05-28 2 Initial CISA Republication of Schneider Electric CPCERT SEVD-2026-132-01 advisory Legal Notice and Terms of Use
Browse saved snapshots