Cybersecurity

CISA Advisories snapshot, Jun 25, 2026

Cybersecurity advisories and mitigation guidance for networks and critical infrastructure.

BioThreat collected this copy on . Dates on individual records come from the publisher. For current guidance, check the publisher’s website or browse the current CISA Advisories feed.

30 recordsDownload JSON

CISA Advisories records

Source published · CISA Cybersecurity Advisory

Using SASE in a Modern TIC 3.0 Solution

Using SASE in a Modern TIC 3.0 Solution CISA’s guidance, The Journey to Zero Trust – Using Secure Access Service Edge in a Modern TIC 3.0 Solution, details how the Trusted Internet Connections (TIC) 3.0 initiative is helping agencies modernize the way their users connect to applications, data and services. While federal agencies are the target audience, any organization looking to modernize its perimeter-based…
Read more of the source summary
architectures, advance zero trust adoption, and improve visibility and control across distributed environments will benefit from this guidance. To learn more about ZT principles, visit Zero Trust. CISA Product Survey We welcome your feedback. CISA Product Survey
Source published · CISA Cybersecurity Advisory

Hubbell Aclara Metrum Cellular Web Interface

View CSAF Summary Successful exploitation of this vulnerability could allow attackers to manipulate critical device settings and repeatedly disrupt operations, potentially causing a loss of communications to the device. The following versions of Hubbell Aclara Metrum Cellular Web Interface are affected: Aclara Metrum Cellular Web Interface CVSS Vendor Equipment Vulnerabilities v3 7.5 Hubbell Hubbell Aclara Metrum…
Read more of the source summary
Cellular Web Interface Missing Authentication for Critical Function Background Critical Infrastructure Sectors: Energy Countries/Areas Deployed: United States Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2026-1840 The Aclara Metrum Cellular Web Interface is vulnerable to unauthorized access due to the absence of authentication controls on critical system functions. This weakness exposes essential configuration settings, allowing attackers to alter operational parameters and trigger system restarts without restriction. Such unauthorized changes can disrupt normal functionality and, if performed repeatedly, may lead to a loss of communications to the device. View CVE Details Affected Products Hubbell Aclara Metrum Cellular Web Interface…
Source published · CISA Cybersecurity Advisory

Siemens WinCC Certificate Manager

View CSAF Summary WinCC Certificate Manager insufficiently protects key material that could allow an attacker to extract sensitive information. Siemens has released a new version for SIMATIC WinCC Unified PC Runtime V21 and recommends to update to the latest version. Siemens recommends specific countermeasures for products where fixes are not, or not yet available. The following versions of Siemens WinCC Certificate…
Read more of the source summary
Manager are affected: SIMATIC WinCC Unified PC Runtime V16 vers:all/* SIMATIC WinCC Unified PC Runtime V17 vers:all/* SIMATIC WinCC Unified PC Runtime V18 vers:all/* SIMATIC WinCC Unified PC Runtime V19 vers:all/* SIMATIC WinCC Unified PC Runtime V20 vers:all/* SIMATIC WinCC Unified PC Runtime V21 vers:intdot/<21.0.2 CVSS Vendor Equipment Vulnerabilities v3 7.1 Siemens Siemens WinCC Certificate Manager Cleartext Storage in a File or on Disk Background Critical Infrastructure Sectors: Critical Manufacturing, Transportation Systems, Energy, Healthcare and Public Health, Financial Services, Government Services and Facilities Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities Expand All + CVE-2026-24349 Insufficient protection of key…
Source published · CISA Cybersecurity Advisory

ABB Freelance Security Lock

View CSAF Summary Successful exploitation of this vulnerability could allow access to underlying OS functions even when Freelance Operations is active, depending on system configuration and user permissions. The following versions of ABB Freelance Security Lock are affected: ABB System Version (<=Freelance 2013) installed with ABB Freelance Security Lock(All versions) vers:all/* ABB System Version (Freelance 2013…
Read more of the source summary
SP1) installed with ABB Freelance Security Lock(All versions) vers:all/* ABB System Version (Freelance 2016) installed with ABB Freelance Security Lock(All versions) vers:all/* ABB System Version (Freelance 2016 SP1) installed with ABB Freelance Security Lock(All versions) vers:all/* ABB System Version (Freelance 2019) installed with ABB Freelance Security Lock(All versions) vers:all/* ABB System Version (Freelance 2019 SP1) installed with ABB Freelance Security Lock(All versions) vers:all/* ABB System Version (Freelance 2019 SP1 FP1) installed with ABB Freelance Security Lock(All versions) vers:all/* ABB System Version (Freelance 2024) installed with ABB Freelance Security Lock(All versions) vers:all/* CVSS Vendor Equipment Vulnerabilities v3 6.6 ABB ABB Freelance…
Source published · CISA Cybersecurity Advisory

Siemens SINEC INS

View CSAF Summary SINEC INS before V1.0 SP2 Update 6 is affected by multiple vulnerabilities. Siemens has released a new version for SINEC INS and recommends to update to the latest version. The following versions of Siemens SINEC INS are affected: SINEC INS vers:intdot/<1.0.2.6 CVSS Vendor Equipment Vulnerabilities v3 8.8 Siemens Siemens SINEC INS Improper Neutralization of Special Elements used in an OS Command…
Read more of the source summary
('OS Command Injection'), Path Traversal: '/dir/../filename', Execution with Unnecessary Privileges, Use of a One-Way Hash with a Predictable Salt Background Critical Infrastructure Sectors: Critical Manufacturing, Transportation Systems, Energy, Healthcare and Public Health, Financial Services, Government Services and Facilities Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities Expand All + CVE-2026-46746 The application does not properly sanitize user input in the /api/sftp/uploadFiles endpoint, allowing the injection of shell command payloads via crafted directory names. These payloads are stored and executed when directory listings are retrieved. This could allow an authenticated remote attacker to execute arbitrary commands on…
Source published · CISA Cybersecurity Advisory

Impact of Linux Kernel vulnerabilities on B&R products

View CSAF Summary B&R is aware of publicly reported vulnerabilities affecting the Linux kernel versions shipped with the products listed as affected in the advisory. Successful local exploitation of these vulnerabilities could allow an attacker to escalate privileges on the affected system. Public proof-of-concept exploits are available for the vulnerabilities described herein. At the time of publication of this…
Read more of the source summary
advisory, B&R had no evidence of active exploitation targeting B&R products. The following versions of Impact of Linux Kernel vulnerabilities on B&R products are affected: Linux for B&R <=12 APROL <APROL-AutoYaST-DVD- V4.4-010.10.260602 X20EDS410 /all CVSS Vendor Equipment Vulnerabilities v3 7.8 B&R Industrial Automation GmbH Impact of Linux Kernel vulnerabilities on B&R products Incorrect Resource Transfer Between Spheres, Write-what-where Condition, Improper Privilege Management, Out-of-bounds Write, Multiple Releases of Same Resource or Handle Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Switzerland Vulnerabilities Expand All + CVE-2026-31431 In the Linux kernel, the following…
Source published · CISA Cybersecurity Advisory

Siemens SIPROTEC 5 Using DIGSI5 Protocol

View CSAF Summary SIPROTEC 5 is vulnerable to arbitrary file uploads by authenticated users using the DIGSI 5 protocol. This could allow an attacker to upload malicious configuration files, potentially causing a permanent denial of service condition. As a mitigation measure, users of the CP050 and CP150 device models are advised to upgrade to version 9.90 or later. For CP300 device models, devices 7ST85 and 7ST86…
Read more of the source summary
are advised to upgrade to version 10.00 or later, while the remaining models should upgrade to version 9.90 or later. These versions introduce an allow-list feature that restricts arbitrary file uploads and reduces the risk associated with this vulnerability. Siemens is preparing fix versions and recommends specific countermeasures for products where fixes are not, or not yet available. The following versions of Siemens SIPROTEC 5 Using DIGSI5 Protocol are affected: SIPROTEC 5 6MD84 (CP300) vers:all/* SIPROTEC 5 6MD85 (CP200) vers:all/* SIPROTEC 5 6MD85 (CP300) vers:all/* SIPROTEC 5 6MD86 (CP200) vers:all/* SIPROTEC 5 6MD86 (CP300) vers:all/* SIPROTEC 5 6MD89 (CP300) vers:all/* SIPROTEC 5 6MU85 (CP300) vers:all/* SIPROTEC 5 7KE85 (CP200) vers:all/* SIPROTEC 5 7KE85…
Source published · CISA Cybersecurity Advisory

CISA Adds Four Known Exploited Vulnerabilities to Catalog

CISA has added four new vulnerabilities to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2025-67038 Lantronix EDS5000 Code Injection Vulnerability CVE-2026-34908 Ubiquiti UniFi OS Improper Access Control Vulnerability CVE-2026-34909 Ubiquiti UniFi OS Path Traversal Vulnerability CVE-2026-34910 Ubiquiti UniFi OS Improper Input Validation Vulnerability These types of…
Read more of the source summary
vulnerabilities are frequent attack vectors for malicious cyber actors and pose significant risks to the federal enterprise. Binding Operational Directive (BOD) 26-04: Prioritizing Security Updates Based on Risk establishes vulnerability management requirements for Federal Civilian Executive Branch (FCEB) agencies. BOD 26-04 reinforces the importance of the KEV Catalog and requires federal agencies to prioritize rapid remediation of high-risk vulnerabilities, specifically those identified by Common Vulnerabilities and Exposures (CVEs) listed in CISA’s KEV Catalog on publicly exposed assets that grant total control of the asset post-exploitation, while deferring action for lower-risk vulnerabilities. BOD 26-04 further establishes basic expectations for when agencies must…
Source published · CISA Cybersecurity Advisory

Siemens Products using OpenSSL

View CSAF Summary OpenSSL has published a stack based buffer overflow vulnerability that allows a remote attacker to cause a denial of service (DoS) or potentially allow for remote code execution. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends specific countermeasures for products where fixes…
Read more of the source summary
are not, or not yet available. The following versions of Siemens Products using OpenSSL are affected: AI Lightweight Inference Server vers:all/* (CVE-2025-15467) Connector for Azure vers:intdot/<1.8.0 (CVE-2025-15467) Databus vers:intdot/<3.3.2 (CVE-2025-15467) HiMed Cockpit vers:all/* (CVE-2025-15467) RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2) vers:all/* (CVE-2025-15467) RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2) vers:all/* (CVE-2025-15467) SCALANCE LPE9403 (6GK5998-3GS00-2AC2) vers:all/* (CVE-2025-15467) SCALANCE LPE9413 (6GK5998-3GS01-2AC2) vers:all/* (CVE-2025-15467) SCALANCE LPE9433 (6GK5998-3GS11-2AC2) vers:all/* (CVE-2025-15467) SCALANCE M804PB (6GK5804-0AP00-2AA2) vers:all/* (CVE-2025-15467) SCALANCE M812-1 ADSL-Router family vers:all/*…
Source published · CISA Cybersecurity Advisory

CISA Urges Hardening Fortinet Devices After Reports of Credential Exposure

Update June 22, 2026: CISA has updated this Alert to incorporate the link to Fortinet’s recent guidance on this activity. CISA is aware of global reports that malicious cyber actors have targeted internet-accessible Fortinet devices across government and private sector organizations using compromised credentials. This activity, referred to as FortiBleed, involves the exposure of leaked credentials associated with…
Read more of the source summary
approximately 74,000 Fortinet devices, including firewalls and virtual private network (VPN) gateways. To defend against this malicious cyber activity, CISA urges impacted Fortinet customers with FortiGate appliances and associated secure sockets layer (SSL) VPN gateways to immediately: Terminate sessions and reset credentials. Terminate all active SSL VPN and administrative sessions. Reset all Fortinet VPN and administrative passwords, especially on internet-facing systems, and enforce strong password policies. Ensure secure credential storage. Confirm your organization’s use of the Password-Based Key Derivation Function 2 (PBKDF2) algorithm to store administrator credentials and remove weaker legacy hashes per Fortinet’s guidance (see, Fortinet's Technical Tip:…
Source published · CISA Cybersecurity Advisory

Schneider Electric Easergy, EcoStruxture, PowerLogic, and Saitel Products

View CSAF Summary Schneider Electric is aware of vulnerabilities in its PowerChute™ Serial Shutdown product. The [PowerChute Serial Shutdown](https://www.se.com/ww/en/product-range/137943580-powerchute-serial-shutdown/#products) product is a UPS management software enabling graceful system shutdown and energy management capabilities for desktop, servers and workstations. Failure to apply the remediation provided…
Read more of the source summary
below may risk improper input validation which could result in disruption of operations and access to system data. The following versions of Schneider Electric Easergy, EcoStruxture, PowerLogic, and Saitel Products are affected: Easergy MiCOM C264 vers:generic/<=D7.33 (CVE-2026-4827) Easergy MiCOM P139 vers:generic/<=P139.678.700 (CVE-2026-4827) Easergy MiCOM P437 vers:generic/<=P437.678.700 (CVE-2026-4827) Easergy MiCOM P439 vers:generic/<=P439.678.700 (CVE-2026-4827) Easergy MiCOM P532 vers:generic/<=P532.678.700 (CVE-2026-4827) Easergy MiCOM P539 vers:generic/<=P539.678.700 (CVE-2026-4827) Easergy MiCOM P631 vers:generic/<=P631.678.700 (CVE-2026-4827) Easergy MiCOM P632 vers:generic/<=P632.678.700 (CVE-2026-4827) Easergy MiCOM P633 vers:generic/<=P633.678.700…
Source published · CISA Cybersecurity Advisory

Mitsubishi Electric MELSEC iQ-F Series

View CSAF Summary Successful exploitation of this vulnerability could allow a remote attacker to cause a denial-of-service (DoS) condition in the affected product by rapidly establishing a large number of TCP connections to it, resulting in an inconsistency in the product's internal connection management process and triggering improper memory access. The following versions of Mitsubishi Electric MELSEC iQ-F Series…
Read more of the source summary
are affected: MELSEC iQ-F Series FX5-EIP EtherNet/IP Module FX5-EIP <=1.000 (CVE-2026-8805) CVSS Vendor Equipment Vulnerabilities v3 7.5 Mitsubishi Electric Mitsubishi Electric MELSEC iQ-F Series Integer Overflow or Wraparound Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Japan Vulnerabilities Expand All + CVE-2026-8805 An integer overflow or wraparound vulnerability exists in the EtherNet/IP function of MELSEC iQ-F Series EtherNet/IP module. This vulnerability could allow a remote attacker to cause a denial-of-service condition in the affected product by rapidly establishing a large number of TCP connections to it, resulting in an inconsistency in the product's internal connection…
Source published · CISA Cybersecurity Advisory

Mitsubishi Electric Co.'s MELSEC iQ-F Series FX5-ENET/IP Ethernet Module

View CSAF Summary Successful exploitation of this vulnerability could allow a remote attacker to cause a denial-of-service (DoS) condition in the affected product by continuously sending a large number of communication packets to the Ethernet port of the product in a short period of time, increasing the processing load of the product, preventing the internal anomaly-detection processing from being performed, and…
Read more of the source summary
causing the communication function to stop. The following versions of Mitsubishi Electric Co.'s MELSEC iQ-F Series FX5-ENET/IP Ethernet Module are affected: Mitsubishi Electric MELSEC iQ-F Series FX5-ENET/IP Ethernet Module FX5-ENET/IP vers:all/* (CVE-2026-8806) CVSS Vendor Equipment Vulnerabilities v3 7.5 Mitsubishi Electric Mitsubishi Electric Co.'s MELSEC iQ-F Series FX5-ENET/IP Ethernet Module Expected Behavior Violation Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Japan Vulnerabilities Expand All + CVE-2026-8806 Expected Behavior Violation (CWE-440) vulnerability exists in MELSEC iQ-F Series FX5-ENET/IP Ethernet Module FX5-ENET/IP. This vulnerability could allow a remote attacker…
Source published · CISA Cybersecurity Advisory

Rockwell Automation FactoryTalk Historian Site Edition

View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to obtain a valid authentication token, perform a denial of service, or crash the system. The following versions of Rockwell Automation FactoryTalk Historian Site Edition are affected: FactoryTalk Historian SE 11 (CVE-2025-13036) FactoryTalk Historian SE <=11.00 (CVE-2025-44019) FactoryTalk Historian SE <=11.00…
Read more of the source summary
(CVE-2025-36539) CVSS Vendor Equipment Vulnerabilities v3 7.7 Rockwell Automation Rockwell Automation FactoryTalk Historian Site Edition Concurrent Execution using Shared Resource with Improper Synchronization ('Race Condition'), Uncaught Exception Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2025-13036 An authentication bypass security issue exists within FactoryTalk Historian Site Edition. By continually sending requests to the login endpoint, an attacker may obtain a valid authentication token. View CVE Details Affected Products Rockwell Automation FactoryTalk Historian Site Edition Vendor: Rockwell Automation Product Version: Rockwell Automation…
Source published · CISA Cybersecurity Advisory

AVer PTC cameras

View CSAF Summary Successful exploitation of this vulnerability could allow arbitrary code execution. The following versions of AVer PTC cameras are affected: PTC500S vers:all/* (CVE-2026-40624) PTC115 vers:all/* (CVE-2026-40624) PTC500+ vers:all/* (CVE-2026-40624) PTC115+ vers:all/* (CVE-2026-40624) CVSS Vendor Equipment Vulnerabilities v3 9.8 AVer AVer PTC cameras Files or Directories Accessible to External…
Read more of the source summary
Parties Background Critical Infrastructure Sectors: Government Services and Facilities, Commercial Facilities, Healthcare and Public Health Countries/Areas Deployed: Worldwide Company Headquarters Location: Taiwan Vulnerabilities Expand All + CVE-2026-40624 Improper input validation in AVer PTC500S, PTC115, PTC500+, and PTC115+ cameras may allow a remote, unauthenticated attacker to achieve arbitrary code execution via a specially crafted web request. View CVE Details Affected Products AVer PTC cameras Vendor: AVer Product Version: AVer PTC500S: vers:all/*, AVer PTC115: vers:all/*, AVer PTC500+: vers:all/*, AVer PTC115+: vers:all/* Product Status: known_affected Remediations Mitigation AVer has provided a firmware fix to address this vulnerability; users can find it at the…
Source published · CISA Cybersecurity Advisory

CISA Adds One Known Exploited Vulnerability to Catalog

CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-20253 Splunk Enterprise Missing Authentication for Critical Function Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 26-04: Prioritizing…
Read more of the source summary
Security Updates Based on Risk establishes vulnerability management requirements for Federal Civilian Executive Branch (FCEB) agencies, updating BOD 22-01. BOD 26-04 reinforces the importance of the KEV Catalog and requires federal agencies to prioritize rapid remediation of high-risk vulnerabilities, specifically those identified by Common Vulnerabilities and Exposures (CVEs) listed in CISA’s Known Exploited Vulnerabilities (KEV) Catalog on publicly exposed assets that grant total control of the asset post-exploitation, while deferring action for lower-risk vulnerabilities. BOD 26-04 further establishes basic expectations for when agencies must check whether threat actors compromised the system before the patch was applied. While BOD 26-04 applies only to FCEB agencies,…
Source published · CISA Cybersecurity Advisory

Apollo Pharmacy Blood Glucose Monitoring System APG-01 BT

View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to obtain sensitive health-related information and prevent legitimate users from establishing a connection with the device. The following versions of Apollo Pharmacy Blood Glucose Monitoring System APG-01 BT are affected: Blood Glucose Monitoring System (Model No. APG-01 BT) 0x0110_v1.1.0 (CVE-2026-50034, CVE-2026-52866) CVSS…
Read more of the source summary
Vendor Equipment Vulnerabilities v3 6.5 Apollo Pharmacy Apollo Pharmacy Blood Glucose Monitoring System APG-01 BT Cleartext Transmission of Sensitive Information, Missing Authorization Background Critical Infrastructure Sectors: Healthcare and Public Health Countries/Areas Deployed: India Company Headquarters Location: India Vulnerabilities Expand All + CVE-2026-50034 An attacker within BLE communication range can passively intercept wireless traffic and obtain sensitive health-related information, including glucose measurement values. View CVE Details Affected Products Apollo Pharmacy Blood Glucose Monitoring System APG-01 BT Vendor: Apollo Pharmacy Product Version: Apollo Pharmacy Blood Glucose Monitoring System (Model No. APG-01 BT): 0x0110_v1.1.0 Product Status:…
Source published · CISA Cybersecurity Advisory

AzeoTech DAQFactory

View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to upload malicious .ctl files that may lead to arbitrary code execution. The following versions of AzeoTech DAQFactory are affected: DAQFactory <=21.1 (CVE-2026-12390) CVSS Vendor Equipment Vulnerabilities v3 7.8 AzeoTech AzeoTech DAQFactory Access of Resource Using Incompatible Type ('Type Confusion') Background Critical…
Read more of the source summary
Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2026-12390 In AzeoTech DAQFactory versions 21.1 and prior, a Type Confusion vulnerability can be exploited by an attacker using specially crafted .ctl files which can result in code execution. View CVE Details Affected Products AzeoTech DAQFactory Vendor: AzeoTech Product Version: AzeoTech DAQFactory: <=21.1 Product Status: known_affected Remediations Mitigation Users are discouraged from using documents from unknown/untrusted sources. Mitigation Users are encouraged to store .ctl files in a folder only writeable by admin-level users. Mitigation Users are encouraged to operate in "Safe Mode" when loading documents…
Source published · CISA Cybersecurity Advisory

Schneider Electric EasyLogic T150 and Saitel DP

View CSAF Summary Successful exploitation this vulnerability could allow an attacker to gain unauthorized access to sensitive files The following versions of Schneider Electric EasyLogic T150 and Saitel DP are affected: Schneider Electric EasyLogic T150 (formerly Saitel DR) Remote Terminal Unit & Controller Firmware installed on Schneider Electric EasyLogic T150 (formerly Saitel DR) Remote Terminal Unit & Controller…
Read more of the source summary
(All versions) vers:semver/<=11.06.31 (CVE-2026-6865) Schneider Electric Saitel DP Remote Terminal Unit & Controller Firmware installed on Schneider Electric Saitel DP Remote Terminal Unit & Controller (All versions) vers:semver/<=11.06.36 (CVE-2026-6865) CVSS Vendor Equipment Vulnerabilities v3 7.1 Schneider Electric Schneider Electric EasyLogic T150 and Saitel DP Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') Background Critical Infrastructure Sectors: Energy, Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: France Vulnerabilities Expand All + CVE-2026-6865 CWE-22: Improper Limitation of a Pathname to a Restricted Directory ("Path Traversal") vulnerability that could cause unauthorized access to…
Source published · CISA Cybersecurity Advisory

Rockwell Automation FactoryTalk Analytics PavilionX

View CSAF Summary Successful exploitation of this vulnerability could result in an attacker executing privileged operations. The following versions of Rockwell Automation FactoryTalk Analytics PavilionX are affected: FactoryTalk Analytics PavilionX <7.01 (CVE-2025-14272) CVSS Vendor Equipment Vulnerabilities v3 7 Rockwell Automation Rockwell Automation FactoryTalk Analytics PavilionX Missing Authorization Background…
Read more of the source summary
Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2025-14272 A security issue was identified in Pavilion due to improper authorization enforcement in API endpoints. This vulnerability can allow an unauthorized actor to execute privileged operations, including user/role management and other administrative actions. View CVE Details Affected Products Rockwell Automation FactoryTalk Analytics PavilionX Vendor: Rockwell Automation Product Version: Rockwell Automation FactoryTalk Analytics PavilionX: <7.01 Product Status: known_affected Remediations Vendor fix Rockwell Automation recommends users update FactoryTalk Analytics PavilionX software to version…
Browse saved snapshots

How to read the archive

Who published the report?

BioThreat brings together reports from the listed public sources. Open the linked title to read the publisher’s original report and any later corrections. Third-party reports retain their own rights and licenses.

Read the source attribution policy

What does each date mean?

A source date is the date the publisher issued or updated a report. A snapshot date is the day BioThreat collected a copy of the feed. The same report can appear in multiple snapshots, and some days have no saved copy.

Browse current public feeds

How can I use the records?

Open a feed or saved snapshot for original links and machine-readable JSON, where available. Use MERIDIAN to compare reporting across sources and dates.

Explore reports in MERIDIAN

Use the Briefing Builder to combine source-linked records with your own analysis and download a report. See a worked food recall briefing.

Build a MERIDIAN briefing