Mitsubishi Electric Co.'s MELSEC iQ-F Series FX5-ENET/IP Ethernet Module

View CSAF Summary Successful exploitation of this vulnerability could allow a remote attacker to cause a denial-of-service (DoS) condition in the affected product by continuously sending a large number of communication packets to the Ethernet port of the product in a short period of time, increasing the processing load of the product, preventing the internal anomaly-detection processing from being performed, and…
Read more of the source summary
causing the communication function to stop. The following versions of Mitsubishi Electric Co.'s MELSEC iQ-F Series FX5-ENET/IP Ethernet Module are affected: Mitsubishi Electric MELSEC iQ-F Series FX5-ENET/IP Ethernet Module FX5-ENET/IP vers:all/* (CVE-2026-8806) CVSS Vendor Equipment Vulnerabilities v3 7.5 Mitsubishi Electric Mitsubishi Electric Co.'s MELSEC iQ-F Series FX5-ENET/IP Ethernet Module Expected Behavior Violation Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Japan Vulnerabilities Expand All + CVE-2026-8806 Expected Behavior Violation (CWE-440) vulnerability exists in MELSEC iQ-F Series FX5-ENET/IP Ethernet Module FX5-ENET/IP. This vulnerability could allow a remote attacker…
Source published · CISA Cybersecurity Advisory

Mitsubishi Electric MELSEC iQ-F Series

View CSAF Summary Successful exploitation of this vulnerability could allow a remote attacker to cause a denial-of-service (DoS) condition in the affected product by rapidly establishing a large number of TCP connections to it, resulting in an inconsistency in the product's internal connection management process and triggering improper memory access. The following versions of Mitsubishi Electric MELSEC iQ-F Series…
Read more of the source summary
are affected: MELSEC iQ-F Series FX5-EIP EtherNet/IP Module FX5-EIP <=1.000 (CVE-2026-8805) CVSS Vendor Equipment Vulnerabilities v3 7.5 Mitsubishi Electric Mitsubishi Electric MELSEC iQ-F Series Integer Overflow or Wraparound Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Japan Vulnerabilities Expand All + CVE-2026-8805 An integer overflow or wraparound vulnerability exists in the EtherNet/IP function of MELSEC iQ-F Series EtherNet/IP module. This vulnerability could allow a remote attacker to cause a denial-of-service condition in the affected product by rapidly establishing a large number of TCP connections to it, resulting in an inconsistency in the product's internal connection…
Source published · CISA Cybersecurity Advisory

Schneider Electric Easergy, EcoStruxture, PowerLogic, and Saitel Products

View CSAF Summary Schneider Electric is aware of vulnerabilities in its PowerChute™ Serial Shutdown product. The [PowerChute Serial Shutdown](https://www.se.com/ww/en/product-range/137943580-powerchute-serial-shutdown/#products) product is a UPS management software enabling graceful system shutdown and energy management capabilities for desktop, servers and workstations. Failure to apply the remediation provided…
Read more of the source summary
below may risk improper input validation which could result in disruption of operations and access to system data. The following versions of Schneider Electric Easergy, EcoStruxture, PowerLogic, and Saitel Products are affected: Easergy MiCOM C264 vers:generic/<=D7.33 (CVE-2026-4827) Easergy MiCOM P139 vers:generic/<=P139.678.700 (CVE-2026-4827) Easergy MiCOM P437 vers:generic/<=P437.678.700 (CVE-2026-4827) Easergy MiCOM P439 vers:generic/<=P439.678.700 (CVE-2026-4827) Easergy MiCOM P532 vers:generic/<=P532.678.700 (CVE-2026-4827) Easergy MiCOM P539 vers:generic/<=P539.678.700 (CVE-2026-4827) Easergy MiCOM P631 vers:generic/<=P631.678.700 (CVE-2026-4827) Easergy MiCOM P632 vers:generic/<=P632.678.700 (CVE-2026-4827) Easergy MiCOM P633 vers:generic/<=P633.678.700…
Source published · CISA Cybersecurity Advisory

Rockwell Automation FactoryTalk Historian Site Edition

View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to obtain a valid authentication token, perform a denial of service, or crash the system. The following versions of Rockwell Automation FactoryTalk Historian Site Edition are affected: FactoryTalk Historian SE 11 (CVE-2025-13036) FactoryTalk Historian SE <=11.00 (CVE-2025-44019) FactoryTalk Historian SE <=11.00…
Read more of the source summary
(CVE-2025-36539) CVSS Vendor Equipment Vulnerabilities v3 7.7 Rockwell Automation Rockwell Automation FactoryTalk Historian Site Edition Concurrent Execution using Shared Resource with Improper Synchronization ('Race Condition'), Uncaught Exception Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2025-13036 An authentication bypass security issue exists within FactoryTalk Historian Site Edition. By continually sending requests to the login endpoint, an attacker may obtain a valid authentication token. View CVE Details Affected Products Rockwell Automation FactoryTalk Historian Site Edition Vendor: Rockwell Automation Product Version: Rockwell Automation…
Source published · CISA Cybersecurity Advisory

AzeoTech DAQFactory (Update A)

View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to upload malicious .ctl files that may lead to arbitrary code execution. The following versions of AzeoTech DAQFactory are affected: DAQFactory <=21.1 CVSS Vendor Equipment Vulnerabilities v3 7.8 AzeoTech AzeoTech DAQFactory Access of Resource Using Incompatible Type ('Type Confusion'), Use After Free Background Critical…
Read more of the source summary
Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2026-12390 In AzeoTech DAQFactory versions 21.1 and prior, a Type Confusion vulnerability can be exploited by an attacker using specially crafted .ctl files which can result in code execution. View CVE Details Affected Products AzeoTech DAQFactory Vendor: AzeoTech Product Version: AzeoTech DAQFactory: <=21.1 Product Status: known_affected Remediations Mitigation Users are discouraged from using documents from unknown/untrusted sources. Mitigation Users are encouraged to store .ctl files in a folder only writeable by admin-level users. Mitigation Users are encouraged to operate in "Safe Mode" when loading documents…
Source published · CISA Cybersecurity Advisory

Apollo Pharmacy Blood Glucose Monitoring System APG-01 BT

View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to obtain sensitive health-related information and prevent legitimate users from establishing a connection with the device. The following versions of Apollo Pharmacy Blood Glucose Monitoring System APG-01 BT are affected: Blood Glucose Monitoring System (Model No. APG-01 BT) 0x0110_v1.1.0 (CVE-2026-50034, CVE-2026-52866) CVSS…
Read more of the source summary
Vendor Equipment Vulnerabilities v3 6.5 Apollo Pharmacy Apollo Pharmacy Blood Glucose Monitoring System APG-01 BT Cleartext Transmission of Sensitive Information, Missing Authorization Background Critical Infrastructure Sectors: Healthcare and Public Health Countries/Areas Deployed: India Company Headquarters Location: India Vulnerabilities Expand All + CVE-2026-50034 An attacker within BLE communication range can passively intercept wireless traffic and obtain sensitive health-related information, including glucose measurement values. View CVE Details Affected Products Apollo Pharmacy Blood Glucose Monitoring System APG-01 BT Vendor: Apollo Pharmacy Product Version: Apollo Pharmacy Blood Glucose Monitoring System (Model No. APG-01 BT): 0x0110_v1.1.0 Product Status:…
Source published · CISA Cybersecurity Advisory

AVer PTC cameras

View CSAF Summary Successful exploitation of this vulnerability could allow arbitrary code execution. The following versions of AVer PTC cameras are affected: PTC500S vers:all/* (CVE-2026-40624) PTC115 vers:all/* (CVE-2026-40624) PTC500+ vers:all/* (CVE-2026-40624) PTC115+ vers:all/* (CVE-2026-40624) CVSS Vendor Equipment Vulnerabilities v3 9.8 AVer AVer PTC cameras Files or Directories Accessible to External…
Read more of the source summary
Parties Background Critical Infrastructure Sectors: Government Services and Facilities, Commercial Facilities, Healthcare and Public Health Countries/Areas Deployed: Worldwide Company Headquarters Location: Taiwan Vulnerabilities Expand All + CVE-2026-40624 Improper input validation in AVer PTC500S, PTC115, PTC500+, and PTC115+ cameras may allow a remote, unauthenticated attacker to achieve arbitrary code execution via a specially crafted web request. View CVE Details Affected Products AVer PTC cameras Vendor: AVer Product Version: AVer PTC500S: vers:all/*, AVer PTC115: vers:all/*, AVer PTC500+: vers:all/*, AVer PTC115+: vers:all/* Product Status: known_affected Remediations Mitigation AVer has provided a firmware fix to address this vulnerability; users can find it at the…
Source published · CISA Cybersecurity Advisory

Schneider Electric EasyLogic T150 and Saitel DP

View CSAF Summary Successful exploitation this vulnerability could allow an attacker to gain unauthorized access to sensitive files The following versions of Schneider Electric EasyLogic T150 and Saitel DP are affected: Schneider Electric EasyLogic T150 (formerly Saitel DR) Remote Terminal Unit & Controller Firmware installed on Schneider Electric EasyLogic T150 (formerly Saitel DR) Remote Terminal Unit & Controller…
Read more of the source summary
(All versions) vers:semver/<=11.06.31 (CVE-2026-6865) Schneider Electric Saitel DP Remote Terminal Unit & Controller Firmware installed on Schneider Electric Saitel DP Remote Terminal Unit & Controller (All versions) vers:semver/<=11.06.36 (CVE-2026-6865) CVSS Vendor Equipment Vulnerabilities v3 7.1 Schneider Electric Schneider Electric EasyLogic T150 and Saitel DP Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') Background Critical Infrastructure Sectors: Energy, Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: France Vulnerabilities Expand All + CVE-2026-6865 CWE-22: Improper Limitation of a Pathname to a Restricted Directory ("Path Traversal") vulnerability that could cause unauthorized access to…
Source published · CISA Cybersecurity Advisory

CISA Adds One Known Exploited Vulnerability to Catalog

CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-20253 Splunk Enterprise Missing Authentication for Critical Function Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 26-04: Prioritizing…
Read more of the source summary
Security Updates Based on Risk establishes vulnerability management requirements for Federal Civilian Executive Branch (FCEB) agencies, updating BOD 22-01. BOD 26-04 reinforces the importance of the KEV Catalog and requires federal agencies to prioritize rapid remediation of high-risk vulnerabilities, specifically those identified by Common Vulnerabilities and Exposures (CVEs) listed in CISA’s Known Exploited Vulnerabilities (KEV) Catalog on publicly exposed assets that grant total control of the asset post-exploitation, while deferring action for lower-risk vulnerabilities. BOD 26-04 further establishes basic expectations for when agencies must check whether threat actors compromised the system before the patch was applied. While BOD 26-04 applies only to FCEB agencies,…
Source published · CISA Cybersecurity Advisory

CISA Urges Hardening Fortinet Devices After Reports of Credential Exposure

Update June 22, 2026: CISA has updated this Alert to incorporate the link to Fortinet’s recent guidance on this activity. CISA is aware of global reports that malicious cyber actors have targeted internet-accessible Fortinet devices across government and private sector organizations using compromised credentials. This activity, referred to as FortiBleed, involves the exposure of leaked credentials associated with…
Read more of the source summary
approximately 74,000 Fortinet devices, including firewalls and virtual private network (VPN) gateways. To defend against this malicious cyber activity, CISA urges impacted Fortinet customers with FortiGate appliances and associated secure sockets layer (SSL) VPN gateways to immediately: Terminate sessions and reset credentials. Terminate all active SSL VPN and administrative sessions. Reset all Fortinet VPN and administrative passwords, especially on internet-facing systems, and enforce strong password policies. Ensure secure credential storage. Confirm your organization’s use of the Password-Based Key Derivation Function 2 (PBKDF2) algorithm to store administrator credentials and remove weaker legacy hashes per Fortinet’s guidance (see, Fortinet's Technical Tip:…
Browse saved snapshots

How to read the archive

Who published the report?

BioThreat brings together reports from the listed public sources. Open the linked title to read the publisher’s original report and any later corrections. Third-party reports retain their own rights and licenses.

Read the source attribution policy

What does each date mean?

A source date is the date the publisher issued or updated a report. A snapshot date is the day BioThreat collected a copy of the feed. The same report can appear in multiple snapshots, and some days have no saved copy.

Browse current public feeds

How can I use the records?

Open a feed or saved snapshot for original links and machine-readable JSON, where available. Use MERIDIAN to compare reporting across sources and dates.

Explore reports in MERIDIAN

Use the Briefing Builder to combine source-linked records with your own analysis and download a report. See a worked food recall briefing.

Build a MERIDIAN briefing