Cybersecurity

CISA Advisories snapshot, Jul 6, 2026

Cybersecurity advisories and mitigation guidance for networks and critical infrastructure.

BioThreat collected this copy on . Dates on individual records come from the publisher. For current guidance, check the publisher’s website or browse the current CISA Advisories feed.

30 recordsDownload JSON

CISA Advisories records · Page 2

Source published · CISA Cybersecurity Advisory

Schneider Electric PowerLogic P7

View CSAF Summary Schneider Electric is aware of a vulnerability in its PowerLogic™ P7 product. The PowerLogic™ P7 is a protection and control platform designed for complex and advanced electrical network applications. Failure to apply the remediation provided below may risk unauthorized execution of privileged commands or loss of HMI operability and configuration functionality, which could result in loss of control…
Read more of the source summary
over system operations and disruption of critical services. The following versions of Schneider Electric PowerLogic P7 are affected: PowerLogic™ P7 vers:intdot/<=0.2.003.001.000 PowerLogic™ P7 0.2.003.001.000 CVSS Vendor Equipment Vulnerabilities v3 7.5 Schneider Electric Schneider Electric PowerLogic P7 NULL Pointer Dereference, Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection'), Reachable Assertion Background Critical Infrastructure Sectors: Commercial Facilities, Critical Manufacturing, Energy Countries/Areas Deployed: Worldwide Company Headquarters Location: France Vulnerabilities Expand All + CVE-2026-9716 CWE-476 NULL Pointer Dereference vulnerability exists that could cause a denial-of-service condition, rendering the…
Source published · CISA Cybersecurity Advisory

Horner Automation Cscape

View CSAF Summary Successful exploitation of this vulnerability could allow a local attacker to disclose information and execute arbitrary code. The following versions of Horner Automation Cscape are affected: Cscape <10.2_SP3 CVSS Vendor Equipment Vulnerabilities v3 7.8 Horner Automation Horner Automation Cscape Out-of-bounds Read Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas…
Read more of the source summary
Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2026-12897 Horner Automation Cscape versions prior to 10.2 SP3 are vulnerable to an Out-of-Bounds Read vulnerability through parsing CSP files. Successful exploitation of this vulnerability could allow an attacker to disclose information and execute arbitrary code. View CVE Details Affected Products Horner Automation Cscape Vendor: Horner Automation Product Version: Horner Automation Cscape: <10.2_SP3 Product Status: known_affected Remediations Vendor fix Horner Automation has released Cscape 10.2 SP3 for users to download. Vendor fix For more information, see the Cscape 10.2 SP3 release notes (https://hornerautomation.com/cscape-software-free/cscape-software/).…
Source published · CISA Cybersecurity Advisory

EVoke Systems Charging Station Management System

View CSAF Summary Successful exploitation of these vulnerabilities could enable attackers to gain unauthorized administrative control over vulnerable charging stations or disrupt charging services through denial-of-service attacks. The following versions of EVoke Systems Charging Station Management System are affected: EVoke CSMS vers:all/* CVSS Vendor Equipment Vulnerabilities v3 9.4 EVoke Systems EVoke Systems…
Read more of the source summary
Charging Station Management System Missing Authentication for Critical Function, Improper Restriction of Excessive Authentication Attempts, Insufficient Session Expiration, Insufficiently Protected Credentials Background Critical Infrastructure Sectors: Energy, Transportation Systems Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2026-40702 WebSocket endpoints lack proper authentication mechanisms, enabling attackers to impersonate charging stations. As a result, attackers can exploit this weakness to gain unauthorized access to sensitive data or perform unauthorized actions. Given that no authentication is required, this can lead to privilege escalation and potentially compromise the security of the entire…
Source published · CISA Cybersecurity Advisory

H.VIEW HV-500S6 IP Camera

View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to execute arbitrary code and upload malicious files to the affected device. The following versions of H.VIEW HV-500S6 IP Camera are affected: H.VIEW HV-500S6 IP Camera IPCAM_V4.06.88.251229 CVSS Vendor Equipment Vulnerabilities v3 7.2 H.VIEW H.VIEW HV-500S6 IP Camera Improper Neutralization of Special Elements used in an OS…
Read more of the source summary
Command ('OS Command Injection'), Unrestricted Upload of File with Dangerous Type Background Critical Infrastructure Sectors: Commercial Facilities Countries/Areas Deployed: Worldwide Company Headquarters Location: China Vulnerabilities Expand All + CVE-2026-55975 A vulnerability exists in H.View IP cameras that could allow an authenticated user to supply unsanitized XML fields to the device's certificate generation interface, which are incorporated into a backend certificate creation command without proper input validation. This may allow for command execution with elevated privileges during certificate generation. View CVE Details Affected Products H.VIEW HV-500S6 IP Camera Vendor: H.VIEW Product Version: H.VIEW H.VIEW HV-500S6 IP Camera: IPCAM_V4.06.88.251229 Product…
Source published · CISA Cybersecurity Advisory

Using SASE in a Modern TIC 3.0 Solution

Using SASE in a Modern TIC 3.0 Solution CISA’s guidance, The Journey to Zero Trust – Using Secure Access Service Edge in a Modern TIC 3.0 Solution, details how the Trusted Internet Connections (TIC) 3.0 initiative is helping agencies modernize the way their users connect to applications, data and services. While federal agencies are the target audience, any organization looking to modernize its perimeter-based…
Read more of the source summary
architectures, advance zero trust adoption, and improve visibility and control across distributed environments will benefit from this guidance. To learn more about ZT principles, visit Zero Trust. CISA Product Survey We welcome your feedback. CISA Product Survey
Source published · CISA Cybersecurity Advisory

CISA Adds Four Known Exploited Vulnerabilities to Catalog

CISA has added four new vulnerabilities to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2025-67038 Lantronix EDS5000 Code Injection Vulnerability CVE-2026-34908 Ubiquiti UniFi OS Improper Access Control Vulnerability CVE-2026-34909 Ubiquiti UniFi OS Path Traversal Vulnerability CVE-2026-34910 Ubiquiti UniFi OS Improper Input Validation Vulnerability These types of…
Read more of the source summary
vulnerabilities are frequent attack vectors for malicious cyber actors and pose significant risks to the federal enterprise. Binding Operational Directive (BOD) 26-04: Prioritizing Security Updates Based on Risk establishes vulnerability management requirements for Federal Civilian Executive Branch (FCEB) agencies. BOD 26-04 reinforces the importance of the KEV Catalog and requires federal agencies to prioritize rapid remediation of high-risk vulnerabilities, specifically those identified by Common Vulnerabilities and Exposures (CVEs) listed in CISA’s KEV Catalog on publicly exposed assets that grant total control of the asset post-exploitation, while deferring action for lower-risk vulnerabilities. BOD 26-04 further establishes basic expectations for when agencies must…
Source published · CISA Cybersecurity Advisory

Impact of Linux Kernel vulnerabilities on B&R products

View CSAF Summary B&R is aware of publicly reported vulnerabilities affecting the Linux kernel versions shipped with the products listed as affected in the advisory. Successful local exploitation of these vulnerabilities could allow an attacker to escalate privileges on the affected system. Public proof-of-concept exploits are available for the vulnerabilities described herein. At the time of publication of this…
Read more of the source summary
advisory, B&R had no evidence of active exploitation targeting B&R products. The following versions of Impact of Linux Kernel vulnerabilities on B&R products are affected: Linux for B&R <=12 APROL <APROL-AutoYaST-DVD- V4.4-010.10.260602 X20EDS410 /all CVSS Vendor Equipment Vulnerabilities v3 7.8 B&R Industrial Automation GmbH Impact of Linux Kernel vulnerabilities on B&R products Incorrect Resource Transfer Between Spheres, Write-what-where Condition, Improper Privilege Management, Out-of-bounds Write, Multiple Releases of Same Resource or Handle Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Switzerland Vulnerabilities Expand All + CVE-2026-31431 In the Linux kernel, the following…
Source published · CISA Cybersecurity Advisory

Siemens SIPROTEC 5 Using DIGSI5 Protocol

View CSAF Summary SIPROTEC 5 is vulnerable to arbitrary file uploads by authenticated users using the DIGSI 5 protocol. This could allow an attacker to upload malicious configuration files, potentially causing a permanent denial of service condition. As a mitigation measure, users of the CP050 and CP150 device models are advised to upgrade to version 9.90 or later. For CP300 device models, devices 7ST85 and 7ST86…
Read more of the source summary
are advised to upgrade to version 10.00 or later, while the remaining models should upgrade to version 9.90 or later. These versions introduce an allow-list feature that restricts arbitrary file uploads and reduces the risk associated with this vulnerability. Siemens is preparing fix versions and recommends specific countermeasures for products where fixes are not, or not yet available. The following versions of Siemens SIPROTEC 5 Using DIGSI5 Protocol are affected: SIPROTEC 5 6MD84 (CP300) vers:all/* SIPROTEC 5 6MD85 (CP200) vers:all/* SIPROTEC 5 6MD85 (CP300) vers:all/* SIPROTEC 5 6MD86 (CP200) vers:all/* SIPROTEC 5 6MD86 (CP300) vers:all/* SIPROTEC 5 6MD89 (CP300) vers:all/* SIPROTEC 5 6MU85 (CP300) vers:all/* SIPROTEC 5 7KE85 (CP200) vers:all/* SIPROTEC 5 7KE85…
Source published · CISA Cybersecurity Advisory

Siemens Products using OpenSSL

View CSAF Summary OpenSSL has published a stack based buffer overflow vulnerability that allows a remote attacker to cause a denial of service (DoS) or potentially allow for remote code execution. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends specific countermeasures for products where fixes…
Read more of the source summary
are not, or not yet available. The following versions of Siemens Products using OpenSSL are affected: AI Lightweight Inference Server vers:all/* (CVE-2025-15467) Connector for Azure vers:intdot/<1.8.0 (CVE-2025-15467) Databus vers:intdot/<3.3.2 (CVE-2025-15467) HiMed Cockpit vers:all/* (CVE-2025-15467) RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2) vers:all/* (CVE-2025-15467) RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2) vers:all/* (CVE-2025-15467) SCALANCE LPE9403 (6GK5998-3GS00-2AC2) vers:all/* (CVE-2025-15467) SCALANCE LPE9413 (6GK5998-3GS01-2AC2) vers:all/* (CVE-2025-15467) SCALANCE LPE9433 (6GK5998-3GS11-2AC2) vers:all/* (CVE-2025-15467) SCALANCE M804PB (6GK5804-0AP00-2AA2) vers:all/* (CVE-2025-15467) SCALANCE M812-1 ADSL-Router family vers:all/*…
Source published · CISA Cybersecurity Advisory

ABB Freelance Security Lock

View CSAF Summary Successful exploitation of this vulnerability could allow access to underlying OS functions even when Freelance Operations is active, depending on system configuration and user permissions. The following versions of ABB Freelance Security Lock are affected: ABB System Version (<=Freelance 2013) installed with ABB Freelance Security Lock(All versions) vers:all/* ABB System Version (Freelance 2013…
Read more of the source summary
SP1) installed with ABB Freelance Security Lock(All versions) vers:all/* ABB System Version (Freelance 2016) installed with ABB Freelance Security Lock(All versions) vers:all/* ABB System Version (Freelance 2016 SP1) installed with ABB Freelance Security Lock(All versions) vers:all/* ABB System Version (Freelance 2019) installed with ABB Freelance Security Lock(All versions) vers:all/* ABB System Version (Freelance 2019 SP1) installed with ABB Freelance Security Lock(All versions) vers:all/* ABB System Version (Freelance 2019 SP1 FP1) installed with ABB Freelance Security Lock(All versions) vers:all/* ABB System Version (Freelance 2024) installed with ABB Freelance Security Lock(All versions) vers:all/* CVSS Vendor Equipment Vulnerabilities v3 6.6 ABB ABB Freelance…
Browse saved snapshots

How to read the archive

Who published the report?

BioThreat brings together reports from the listed public sources. Open the linked title to read the publisher’s original report and any later corrections. Third-party reports retain their own rights and licenses.

Read the source attribution policy

What does each date mean?

A source date is the date the publisher issued or updated a report. A snapshot date is the day BioThreat collected a copy of the feed. The same report can appear in multiple snapshots, and some days have no saved copy.

Browse current public feeds

How can I use the records?

Open a feed or saved snapshot for original links and machine-readable JSON, where available. Use MERIDIAN to compare reporting across sources and dates.

Explore reports in MERIDIAN

Use the Briefing Builder to combine source-linked records with your own analysis and download a report. See a worked food recall briefing.

Build a MERIDIAN briefing