CISA Advisories snapshot, Jul 13, 2026

Cybersecurity advisories and mitigation guidance for networks and critical infrastructure.

BioThreat collected this copy on . Dates on individual records come from the publisher. For current guidance, check the publisher’s website or browse the current CISA Advisories feed.

30 recordsDownload JSON

CISA Advisories records · Page 2

Source published · CISA Cybersecurity Advisory

Delta Electronics DVP12SE PLC

View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to remotely issue commands, modify operational values, interfere with control logic, and alter device behavior without authentication or privilege enforcement. The following versions of Delta Electronics DVP12SE PLC are affected: DVP12SE PLC vers:all/* (CVE-2026-12819, CVE-2026-12818) CVSS Vendor Equipment Vulnerabilities v3…
Read more of the source summary
9.8 Delta Electronics Delta Electronics DVP12SE PLC Missing Authentication for Critical Function, Allocation of Resources Without Limits or Throttling Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Taiwan Vulnerabilities Expand All + CVE-2026-12819 The Delta Electronics DVP12SE PLC exposes a Modbus TCP service over a specified port without authentication or access control, permitting unauthenticated interaction with security-sensitive PLC functions. The device accepts Modbus commands from any reachable network source without requiring credentials, privilege validation, or operator approval, allowing unauthorized read and write access to coils, holding registers, operational memory,…
Source published · CISA Cybersecurity Advisory

Mitsubishi Electric MELSOFT Update Manager SW1DND-UDM-M

View CSAF Summary Successful exploitation of these vulnerabilities could allow a local attacker to tamper with or destroy information in the affected product, cause a denial-of-service condition in the affected product, or execute arbitrary code when a specially crafted archive file is decompressed by the 7-Zip component included in MELSOFT Update Manager. The following versions of Mitsubishi Electric MELSOFT Update…
Read more of the source summary
Manager SW1DND-UDM-M are affected: MELSOFT Update Manager SW1DND-UDM-M >=1.000A|<=1.014Q (CVE-2025-53816, CVE-2025-53817, CVE-2025-55188, CVE-2025-11001) CVSS Vendor Equipment Vulnerabilities v3 8.8 Mitsubishi Electric Mitsubishi Electric MELSOFT Update Manager SW1DND-UDM-M Heap-based Buffer Overflow, NULL Pointer Dereference, Improper Link Resolution Before File Access ('Link Following'), Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Japan Vulnerabilities Expand All + CVE-2025-53816 A heap-based buffer overflow vulnerability exists in the 7-Zip component included in MELSOFT Update Manager SW1DND-UDM-M.…
Source published · CISA Cybersecurity Advisory

OFFIS DCMTK Toolkit

View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to write files, access unauthorized information, exhaust memory, or crash affected DCMTK client or server processes. The following versions of OFFIS DCMTK Toolkit are affected: DCMTK <=3.7.0 (CVE-2026-50003, CVE-2026-50254, CVE-2026-35505, CVE-2026-52868, CVE-2026-44628) CVSS Vendor Equipment Vulnerabilities v3 9.8 OFFIS OFFIS…
Read more of the source summary
DCMTK Toolkit Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal'), Missing Release of Memory after Effective Lifetime, Access of Resource Using Incompatible Type ('Type Confusion') Background Critical Infrastructure Sectors: Healthcare and Public Health Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities Expand All + CVE-2026-50003 A malicious or compromised server can make a DCMTK client using bit-preserving C-GET storage mode write files outside the chosen output directory, using both relative (../) paths and absolute paths. View CVE Details Affected Products OFFIS DCMTK Toolkit Vendor: OFFIS Product Version: OFFIS DCMTK: <=3.7.0 Product Status: known_affected Remediations Mitigation The maintainer was…
Source published · CISA Cybersecurity Advisory

Frangoteam FUXA SCADA/HMI

View CSAF Summary Successful exploitation of this vulnerability could allow an unauthenticated remote attacker to enumerate all user accounts and role assignments on a FUXA SCADA/HMI instance. The following versions of Frangoteam FUXA SCADA/HMI are affected: FUXA SCADA/HMI <=1.3.1 (CVE-2026-13207) CVSS Vendor Equipment Vulnerabilities v3 7.5 Frangoteam Frangoteam FUXA SCADA/HMI Authentication Bypass by Spoofing…
Read more of the source summary
Background Critical Infrastructure Sectors: Critical Manufacturing, Energy, Water and Wastewater Countries/Areas Deployed: Worldwide Company Headquarters Location: Switzerland Vulnerabilities Expand All + CVE-2026-13207 FUXA versions 1.3.1 and prior contain an authentication bypass vulnerability via dot-segment path normalization in the REST API. The API router fails to normalize dot-segment sequences before applying authentication middleware, allowing unauthenticated requests to access protected endpoints by prefixing paths with dot-segments such as /api/./users, /api/./roles, and /api/project/../users. These requests bypass authentication checks and return sensitive user and role data without credentials. View CVE Details Affected Products Frangoteam FUXA SCADA/HMI…
Source published · CISA Cybersecurity Advisory

Schneider Electric EcoStruxure IT Data Center Expert

View CSAF Summary Schneider Electric is aware of a vulnerability in its EcoStruxure™ IT Data Center Expert. The EcoStruxure™ IT Data Center Expert product is a scalable monitoring software that collects, organizes, and distributes critical device information providing a comprehensive view of equipment. Failure to apply the remediation provided below may risk information disclosure. The following versions of…
Read more of the source summary
Schneider Electric EcoStruxure IT Data Center Expert are affected: EcoStruxure IT Data Center Expert vers:intdot/<=9.1.1, 9.1.2 (CVE-2026-8045) CVSS Vendor Equipment Vulnerabilities v3 6.5 Schneider Electric Schneider Electric EcoStruxure IT Data Center Expert Improper Restriction of XML External Entity Reference Background Critical Infrastructure Sectors: Information Technology, Critical Manufacturing, Energy Countries/Areas Deployed: Worldwide Company Headquarters Location: France Vulnerabilities Expand All + CVE-2026-8045 CWE-611: Improper Restriction of XML External Entity Reference vulnerability exists that could cause information disclosure of server-side file contents when an attacker with a Data Center Expert user account submits crafted XML payloads to SOAP service…
Source published · CISA Cybersecurity Advisory

CISA Adds One Known Exploited Vulnerability to Catalog

CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-48558 SimpleHelp Authentication Bypass Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 26-04: Prioritizing Security Updates Based on Risk…
Read more of the source summary
establishes vulnerability management requirements for Federal Civilian Executive Branch (FCEB) agencies. BOD 26-04 reinforces the importance of the KEV Catalog and requires federal agencies to prioritize rapid remediation of high-risk vulnerabilities, specifically those identified by Common Vulnerabilities and Exposures (CVEs) listed in CISA’s KEV Catalog on publicly exposed assets that grant total control of the asset post-exploitation, while deferring action for lower-risk vulnerabilities. BOD 26-04 further establishes basic expectations for when agencies must check whether threat actors compromised the system before the patch was applied. While BOD 26-04 applies only to FCEB agencies, CISA encourages all organizations to adopt risk-based vulnerability management and…
Source published · CISA Cybersecurity Advisory

Russian Intelligence Services Continue to Target Commercial Messaging Applications

CISA and the Federal Bureau of Investigation (FBI) issued an updated Public Service Announcement (PSA) warning of Russian Intelligence Services (RIS) cyber threat actors targeting commercial messaging applications in ongoing phishing campaigns. This PSA is an update to the March 2026 Russian Intelligence Services Target Commercial Messaging Application Accounts and provides recent tactics, recommended mitigations,…
Read more of the source summary
and samples of phishing messages.
Source published · CISA Cybersecurity Advisory

OHIF Viewers DICOM

View CSAF Summary Successful exploitation of this vulnerability in a custom integration version could allow an attacker to steal an authenticated clinician's token via a crafted link. The following versions of OHIF Viewers DICOM are affected: OHIF DICOM Web Viewer Framework <=v3.12.0 CVSS Vendor Equipment Vulnerabilities v3 8.2 Open Health Imaging Foundation (OHIF) OHIF Viewers DICOM Server-Side Request Forgery…
Read more of the source summary
(SSRF) Background Critical Infrastructure Sectors: Healthcare and Public Health Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2026-12473 Two data sources (DICOMWebProxy and DICOMJSON) shipped in the default configuration fetch an arbitrary URL parameter without validation. A global authentication service in OHIF automatically injects the authenticated user's OIDC Bearer token into the resulting requests, sending it to the attacker-controlled server. DICOMweb data sources are not impacted. View CVE Details Affected Products OHIF Viewers DICOM Vendor: Open Health Imaging Foundation (OHIF) Product Version: Open Health Imaging Foundation (OHIF) OHIF DICOM Web Viewer Framework: <=v3.12.0 Product Status:…
Source published · CISA Cybersecurity Advisory

Schneider Electric PowerLogic P7

View CSAF Summary Schneider Electric is aware of a vulnerability in its PowerLogic™ P7 product. The PowerLogic™ P7 is a protection and control platform designed for complex and advanced electrical network applications. Failure to apply the remediation provided below may risk unauthorized execution of privileged commands or loss of HMI operability and configuration functionality, which could result in loss of control…
Read more of the source summary
over system operations and disruption of critical services. The following versions of Schneider Electric PowerLogic P7 are affected: PowerLogic™ P7 vers:intdot/<=0.2.003.001.000 PowerLogic™ P7 0.2.003.001.000 CVSS Vendor Equipment Vulnerabilities v3 7.5 Schneider Electric Schneider Electric PowerLogic P7 NULL Pointer Dereference, Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection'), Reachable Assertion Background Critical Infrastructure Sectors: Commercial Facilities, Critical Manufacturing, Energy Countries/Areas Deployed: Worldwide Company Headquarters Location: France Vulnerabilities Expand All + CVE-2026-9716 CWE-476 NULL Pointer Dereference vulnerability exists that could cause a denial-of-service condition, rendering the…
Source published · CISA Cybersecurity Advisory

CISA Adds Two Known Exploited Vulnerabilities to Catalog

CISA has added two new vulnerabilities to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-12569 PTC Windchill and FlexPLM Improper Input Validation Vulnerability CVE-2026-20230 Cisco Unified Communications Manager Server-Side Request Forgery (SSRF) Vulnerability These types of vulnerabilities are frequent attack vectors for malicious cyber actors and pose…
Read more of the source summary
significant risks to the federal enterprise. Binding Operational Directive (BOD) 26-04: Prioritizing Security Updates Based on Risk establishes vulnerability management requirements for Federal Civilian Executive Branch (FCEB) agencies. BOD 26-04 reinforces the importance of the KEV Catalog and requires federal agencies to prioritize rapid remediation of high-risk vulnerabilities, specifically those identified by Common Vulnerabilities and Exposures (CVEs) listed in CISA’s KEV Catalog on publicly exposed assets that grant total control of the asset post-exploitation, while deferring action for lower-risk vulnerabilities. BOD 26-04 further establishes basic expectations for when agencies must check whether threat actors compromised the system before the patch was applied. While…
Browse saved snapshots

How to read the archive

Who published the report?

BioThreat brings together reports from the listed public sources. Open the linked title to read the publisher’s original report and any later corrections. Third-party reports retain their own rights and licenses.

Read the source attribution policy

What does each date mean?

A source date is the date the publisher issued or updated a report. A snapshot date is the day BioThreat collected a copy of the feed. The same report can appear in multiple snapshots, and some days have no saved copy.

Browse current public feeds

How can I use the records?

Open a feed or saved snapshot for original links and machine-readable JSON, where available. Use MERIDIAN to compare reporting across sources and dates.

Explore reports in MERIDIAN

Use the Briefing Builder to combine source-linked records with your own analysis and download a report. See a worked food recall briefing.