Cybersecurity

CISA Advisories snapshot, Jul 16, 2026

Cybersecurity advisories and mitigation guidance for networks and critical infrastructure.

BioThreat collected this copy on . Dates on individual records come from the publisher. For current guidance, check the publisher’s website or browse the current CISA Advisories feed.

30 recordsDownload JSON

CISA Advisories records · Page 2

Source published · CISA Cybersecurity Advisory

Digi International PortServer TS, Digi One SP IA

View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to bypass authentication and gain access to restricted resources, obtain credentials, and inject malicious scripts. The following versions of Digi International PortServer TS, Digi One SP IA are affected: PortServer TS Digi One SP Digi One SP IA Digi One IA CVSS Vendor Equipment Vulnerabilities v3 5.9 Digi International Digi…
Read more of the source summary
International PortServer TS, Digi One SP IA Incorrect Authorization, Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') Background Critical Infrastructure Sectors: Critical Manufacturing, Communications, Information Technology, Transportation Systems Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2026-12352 The vulnerability allows an unauthenticated actor to bypass authentication and gain access to restricted resources on the device. View CVE Details Affected Products Digi International PortServer TS, Digi One SP IA Vendor: Digi International Product Version: Digi International PortServer TS: <Firmware_2025, Digi International Digi One SP: <Firmware_2025, Digi…
Source published · CISA Cybersecurity Advisory

Labcenter Proteus 9

View CSAF Summary Successful exploitation of these vulnerabilities could disclose information and allow a malicious user to execute arbitrary code on affected installations. The following versions of Labcenter Proteus 9 are affected: Proteus 9.1_SP4_Build_42914 CVSS Vendor Equipment Vulnerabilities v3 7.8 Labcenter Electronics Labcenter Proteus 9 Out-of-bounds Write, Stack-based Buffer Overflow, Use After Free…
Read more of the source summary
Background Critical Infrastructure Sectors: Communications, Critical Manufacturing, Defense Industrial Base, Energy, Healthcare and Public Health, Transportation Systems, Water and Wastewater Countries/Areas Deployed: Worldwide Company Headquarters Location: United Kingdom Vulnerabilities Expand All + CVE-2026-42953 The application contains an out-of-bounds write vulnerability that can be exploited by an attacker to cause the program to write data past the end of an allocated memory buffer. This can lead to arbitrary code execution. View CVE Details Affected Products Labcenter Proteus 9 Vendor: Labcenter Electronics Product Version: Labcenter Electronics Proteus: 9.1_SP4_Build_42914 Product Status: known_affected Remediations Vendor fix Labcenter recommends ensuring you are…
Source published · CISA Cybersecurity Advisory

Siemens Mendix Studio Pro

View CSAF Summary Mendix Studio Pro versions before V11.12 are affected by a file parsing vulnerability that could be triggered when the application reads specially crafted malicious project during the build pipeline. This could allow an attacker to execute arbitrary code in the context of that user. Siemens has released new versions for several affected products and recommends to update to the latest versions.…
Read more of the source summary
Siemens is preparing further fix versions and recommends countermeasures for products where fixes are not, or not yet available. The following versions of Siemens Mendix Studio Pro are affected: Mendix Studio Pro 10.11 vers:all/* Mendix Studio Pro 10.12 vers:all/* Mendix Studio Pro 10.13 vers:all/* Mendix Studio Pro 10.14 vers:all/* Mendix Studio Pro 10.15 vers:all/* Mendix Studio Pro 10.16 vers:all/* Mendix Studio Pro 10.17 vers:all/* Mendix Studio Pro 10.18 vers:all/* Mendix Studio Pro 10.19 vers:all/* Mendix Studio Pro 10.20 vers:all/* Mendix Studio Pro 10.21 vers:all/* Mendix Studio Pro 10.22 vers:all/* Mendix Studio Pro 10.23 vers:all/* Mendix Studio Pro 10.24 vers:intdot/<10.24.21 Mendix Studio Pro 11.0 vers:all/* Mendix Studio Pro 11.1 vers:all/* Mendix Studio Pro…
Source published · CISA Cybersecurity Advisory

ST Engineering iDirect iQ-Series Terminals

View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to gain unauthorized access to device information or cause a denial-of-service condition. The following versions of ST Engineering iDirect iQ-Series Terminals are affected: Evolution iQ‑Series terminals <=4.5.2.1 (CVE-2026-38059, CVE-2026-38057) 3315‑Series terminals <=4.5.2.1 (CVE-2026-38059, CVE-2026-38057) 9‑Series…
Read more of the source summary
terminals <=4.5.2.1 (CVE-2026-38059, CVE-2026-38057) CVSS Vendor Equipment Vulnerabilities v3 8.1 ST Engineering iDirect ST Engineering iDirect iQ-Series Terminals Missing Authentication for Critical Function, Cross-Site Request Forgery (CSRF) Background Critical Infrastructure Sectors: Communications, Defense Industrial Base, Energy, Government Services and Facilities, Transportation Systems Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2026-38059 The iDirect iQ200 exposes the /api/identity and /api/ REST API endpoints without authentication. An unauthenticated attacker with network access can retrieve sensitive device information including the serial number, Device ID (DID), Terminal Private Key identifier…
Source published · CISA Cybersecurity Advisory

Gardyn IoT Hub

View CSAF Summary Successful exploitation of these vulnerabilities could allow unauthenticated users to access and control IoT Hub managed devices. The following versions of Gardyn IoT Hub are affected: Home Firmware Studio Firmware Cloud API <2.12.2026 (CVE-2026-13768, CVE-2026-55726, CVE-2026-54477) CVSS Vendor Equipment Vulnerabilities v3 10 Gardyn Gardyn IoT Hub Use of Hard-coded Credentials, Exposure of…
Read more of the source summary
Sensitive System Information to an Unauthorized Control Sphere, Improper Neutralization of HTTP Headers for Scripting Syntax Background Critical Infrastructure Sectors: Food and Agriculture Countries/Areas Deployed: United States Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2026-13768 Gardyn devices expose a privileged iothubowner key. Access to this key will allow a malicious user to invoke an IoTHub Registry Manager function which returns connection information for all Gardyn Home Kit and Studio devices. Access to this key also allows a malicious user to execute arbitrary commands on a specific connected device and may allow the malicious user to pivot to other devices on the user's network. View CVE Details Affected Products Gardyn IoT Hub…
Source published · CISA Cybersecurity Advisory

CubeSpace CW0057 Reaction Wheel

View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to upload arbitrary malicious firmware to the device. The following versions of CubeSpace CW0057 Reaction Wheel are affected: CW0057 Reaction Wheel CVSS Vendor Equipment Vulnerabilities v3 6.1 CubeSpace CubeSpace CW0057 Reaction Wheel Improper Verification of Cryptographic Signature Background Critical Infrastructure Sectors:…
Read more of the source summary
Communications Countries/Areas Deployed: Worldwide Company Headquarters Location: South Africa Vulnerabilities Expand All + CVE-2026-13743 CubeSpace CW0057 Reaction Wheel firmware versions prior to 5.0.20 are vulnerable to an Improper Verification of Cryptographic Signature vulnerability. This could allow an attacker with physical access to the product to upload arbitrary malicious firmware to the device without authentication. View CVE Details Affected Products CubeSpace CW0057 Reaction Wheel Vendor: CubeSpace Product Version: CubeSpace CW0057 Reaction Wheel: <firmware_5.0.20 Product Status: known_affected Remediations Vendor fix CubeSpace has released the following firmware versions for users to enable: Firmware version 5.0.20. Firmware version 5.0.20 introduces the…
Source published · CISA Cybersecurity Advisory

CISA Adds One Known Exploited Vulnerability to Catalog

CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-45659 Microsoft SharePoint Server Deserialization of Untrusted Data Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 26-04: Prioritizing…
Read more of the source summary
Security Updates Based on Risk establishes vulnerability management requirements for Federal Civilian Executive Branch (FCEB) agencies. BOD 26-04 reinforces the importance of the KEV Catalog and requires federal agencies to prioritize rapid remediation of high-risk vulnerabilities, specifically those identified by Common Vulnerabilities and Exposures (CVEs) listed in CISA’s KEV Catalog on publicly exposed assets that grant total control of the asset post-exploitation, while deferring action for lower-risk vulnerabilities. BOD 26-04 further establishes basic expectations for when agencies must check whether threat actors compromised the system before the patch was applied. While BOD 26-04 applies only to FCEB agencies, CISA encourages all organizations to adopt risk-based…
Source published · CISA Cybersecurity Advisory

XZ Utils vulnerability impacting B&R Products

View CSAF Summary An update is available that resolves vulnerability in the product versions listed as affected in the advisory. An attacker who successfully exploited this vulnerability could cause the product to stop or corrupt memory data. The following versions of XZ Utils vulnerability impacting B&R Products are affected: PPC3100 <1.8.1, 1.8.1 (CVE-2025-31115) C50 <1.8.0, 1.8.0 (CVE-2025-31115) C80 <1.8.0,…
Read more of the source summary
1.8.0 (CVE-2025-31115) FT50 <1.8.1, 1.8.1 (CVE-2025-31115) MT50 <1.8.1, 1.8.1 (CVE-2025-31115) T30 <1.8.0, 1.8.0 (CVE-2025-31115) T80 <1.8.0, 1.8.0 (CVE-2025-31115) T50 <1.8.1, 1.8.1 (CVE-2025-31115) CVSS Vendor Equipment Vulnerabilities v3 7.5 B&R Industrial Automation GmbH XZ Utils vulnerability impacting B&R Products Race Condition within a Thread Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Switzerland Vulnerabilities Expand All + CVE-2025-31115 XZ Utils provide a general-purpose data-compression library plus command-line tools. In XZ Utils 5.3.3alpha to 5.8.0, the multithreaded .xz decoder in liblzma has a bug where invalid input can at least result in a crash. The effects include…
Source published · CISA Cybersecurity Advisory

Delta Electronics DVP12SE PLC

View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to remotely issue commands, modify operational values, interfere with control logic, and alter device behavior without authentication or privilege enforcement. The following versions of Delta Electronics DVP12SE PLC are affected: DVP12SE PLC vers:all/* (CVE-2026-12819, CVE-2026-12818) CVSS Vendor Equipment Vulnerabilities v3…
Read more of the source summary
9.8 Delta Electronics Delta Electronics DVP12SE PLC Missing Authentication for Critical Function, Allocation of Resources Without Limits or Throttling Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Taiwan Vulnerabilities Expand All + CVE-2026-12819 The Delta Electronics DVP12SE PLC exposes a Modbus TCP service over a specified port without authentication or access control, permitting unauthenticated interaction with security-sensitive PLC functions. The device accepts Modbus commands from any reachable network source without requiring credentials, privilege validation, or operator approval, allowing unauthorized read and write access to coils, holding registers, operational memory,…
Source published · CISA Cybersecurity Advisory

StoneFly Storage Concentrator

View CSAF Summary Successful exploitation of these vulnerabilities could allow attackers to gain broad unauthorized access, execute arbitrary commands with root privileges, steal sensitive data, and perform actions on behalf of legitimate users across interconnected systems. The following versions of StoneFly Storage Concentrator are affected: Storage Concentrator <8.0.4.22 (CVE-2026-56415, CVE-2026-55721,…
Read more of the source summary
CVE-2026-50040) Storage Concentrator Virtual Machine <8.0.4.22 (CVE-2026-56415, CVE-2026-55721, CVE-2026-50040) Storage Concentrator <8.0.4.26 (CVE-2026-50110) Storage Concentrator Virtual Machine <8.0.4.26 (CVE-2026-50110) Storage Concentrator <8.0.4.29 (CVE-2026-56413) Storage Concentrator Virtual Machine <8.0.4.29 (CVE-2026-56413) CVSS Vendor Equipment Vulnerabilities v3 10 StoneFly StoneFly Storage Concentrator Use of Hard-coded Credentials, Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection'), Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection'), Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') Background Critical Infrastructure Sectors: Defense Industrial Base, Energy,…
Browse saved snapshots

How to read the archive

Who published the report?

BioThreat brings together reports from the listed public sources. Open the linked title to read the publisher’s original report and any later corrections. Third-party reports retain their own rights and licenses.

Read the source attribution policy

What does each date mean?

A source date is the date the publisher issued or updated a report. A snapshot date is the day BioThreat collected a copy of the feed. The same report can appear in multiple snapshots, and some days have no saved copy.

Browse current public feeds

How can I use the records?

Open a feed or saved snapshot for original links and machine-readable JSON, where available. Use MERIDIAN to compare reporting across sources and dates.

Explore reports in MERIDIAN

Use the Briefing Builder to combine source-linked records with your own analysis and download a report. See a worked food recall briefing.

Build a MERIDIAN briefing