Cybersecurity

CISA Advisories snapshot, Jul 17, 2026

Cybersecurity advisories and mitigation guidance for networks and critical infrastructure.

BioThreat collected this copy on . Dates on individual records come from the publisher. For current guidance, check the publisher’s website or browse the current CISA Advisories feed.

30 recordsDownload JSON

CISA Advisories records · Page 2

Source published · CISA Cybersecurity Advisory

CISA Adds Two Known Exploited Vulnerabilities to Catalog

CISA has added two new vulnerabilities to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-48939 iCagenda Unrestricted Upload of File with Dangerous Type Vulnerability CVE-2026-56291 Balbooa Forms Unrestricted Upload of File with Dangerous Type Vulnerability These types of vulnerabilities are a frequent attack vector for malicious cyber actors and pose significant…
Read more of the source summary
risks to the federal enterprise. Binding Operational Directive (BOD) 26-04: Prioritizing Security Updates Based on Risk establishes vulnerability management requirements for Federal Civilian Executive Branch (FCEB) agencies. BOD 26-04 reinforces the importance of the KEV Catalog and requires federal agencies to prioritize rapid remediation of high-risk vulnerabilities, specifically those identified by Common Vulnerabilities and Exposures (CVEs) listed in CISA’s KEV Catalog on publicly exposed assets that grant total control of the asset post-exploitation, while deferring action for lower-risk vulnerabilities. BOD 26-04 further establishes basic expectations for when agencies must check whether threat actors compromised the system before the patch was applied. While BOD…
Source published · CISA Cybersecurity Advisory

OpenPLC v3

View CSAF Summary Successful exploitation of this vulnerability could allow an authenticated attacker to write arbitrary files to the filesystem and escalate this into arbitrary native code execution through the normal OpenPLC program compilation process, potentially resulting in code execution as the OpenPLC runtime user. The following versions of OpenPLC v3 are affected: OpenPLC v3 CVSS Vendor Equipment…
Read more of the source summary
Vulnerabilities v3 9.9 OpenPLC OpenPLC v3 External Control of File Name or Path Background Critical Infrastructure Sectors: Critical Manufacturing, Energy, Transportation Systems, Water and Wastewater Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2026-14480 OpenPLC Runtime v3 contains an authenticated arbitrary file write vulnerability in the legacy web UI program‑upload workflow. The application stores an attacker‑supplied filename (prog_file) directly into the Programs.File database field and later uses this value as the destination path for an uploaded file without validating or restricting the path. Because Python os.path.join() honors attacker‑controlled absolute paths, an authenticated user can write…
Source published · CISA Cybersecurity Advisory

Schneider Electric Easergy MiCOM Px40 Series

View CSAF Summary Schneider Electric is aware of a vulnerability in its Easergy MiCOM Px40 Series products. The [Easergy MiCOM Px40](https://www.se.com/ww/en/product-subcategory/4725-easergy-micom-px40-series/?filter=business-6-medium-voltage-distribution-and-grid-automation) is a protection relay series for Medium Voltage, High Voltage and Extra High Voltage protection. Failure to apply the mitigations provided…
Read more of the source summary
below may risk unauthorized exposure of basic device identification through the SNMP protocol. The following versions of Schneider Electric Easergy MiCOM Px40 Series are affected: Easergy MiCOM P14x All versions prior to B4A Easergy MiCOM P24x All versions prior to D3A Easergy MiCOM P341 All versions prior to E3F Easergy MiCOM P342, P343, P344, P345 All versions prior to B3F Easergy MiCOM P442, P444 All versions prior to E3A Easergy MiCOM P443, P445, P446, P543, P544, P545, P546 All versions prior to H6A Easergy MiCOM P841 All versions prior to G6A Easergy MiCOM P643 All versions prior to B3F Easergy MiCOM P642, P645 All versions prior to B4A Easergy MiCOM P741, P742, P743 All versions prior to B2A Easergy MiCOM P746 All versions prior to B4E Easergy MiCOM P746 All…
Source published · CISA Cybersecurity Advisory

Schneider Electric PowerChute Serial Shutdown

View CSAF Summary Successful exploitation of these vulnerabilities could allow attackers to overwrite critical files, forge or inject malicious log data, gain unauthorized account access, trigger denial‑of‑service conditions, truncate or alter logging information, reset user credentials, or expose sensitive information. The following versions of Schneider Electric PowerChute Serial Shutdown are affected: PowerChute…
Read more of the source summary
Serial Shutdown <=1.4 CVSS Vendor Equipment Vulnerabilities v3 6.1 SuSE, Schneider Electric, Red Hat, Microsoft Schneider Electric PowerChute Serial Shutdown Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal'), Improper Encoding or Escaping of Output, Improper Restriction of Excessive Authentication Attempts, Uncontrolled Resource Consumption, Improper Validation of Specified Quantity in Input, Improper Neutralization of CRLF Sequences ('CRLF Injection'), Insertion of Sensitive Information into Log File Background Critical Infrastructure Sectors: Communications, Critical Manufacturing, Energy, Healthcare and Public Health, Information Technology, Transportation Systems Countries/Areas Deployed: Worldwide Company Headquarters Location: France…
Source published · CISA Cybersecurity Advisory

CISA Adds One Known Exploited Vulnerability to Catalog

CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-48282 Adobe ColdFusion Path Traversal Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 26-04: Prioritizing Security Updates Based on Risk…
Read more of the source summary
establishes vulnerability management requirements for Federal Civilian Executive Branch (FCEB) agencies. BOD 26-04 reinforces the importance of the KEV Catalog and requires federal agencies to prioritize rapid remediation of high-risk vulnerabilities, specifically those identified by Common Vulnerabilities and Exposures (CVEs) listed in CISA’s KEV Catalog on publicly exposed assets that grant total control of the asset post-exploitation, while deferring action for lower-risk vulnerabilities. BOD 26-04 further establishes basic expectations for when agencies must check whether threat actors compromised the system before the patch was applied. While BOD 26-04 applies only to FCEB agencies, CISA encourages all organizations to adopt risk-based vulnerability management and…
Source published · CISA Cybersecurity Advisory

Hydro-Québec Le Circuit Electrique charging station backend

View CSAF Summary Successful exploitation of these vulnerabilities could lead to privilege escalation, or result in a denial-of-service attack. The following versions of Hydro-Québec Le Circuit Electrique charging station backend are affected: Le Circuit Electrique charging station backend CVSS Vendor Equipment Vulnerabilities v3 9.8 Hydro-Québec Hydro-Québec Le Circuit Electrique charging station backend Improper…
Read more of the source summary
Access Control, Improper Restriction of Excessive Authentication Attempts, Insufficient Session Expiration Background Critical Infrastructure Sectors: Transportation Systems Countries/Areas Deployed: Canada Company Headquarters Location: Canada Vulnerabilities Expand All + CVE-2026-20744 The charging station websocket endpoint accepts connections without proper authentication, which could lead to privilege escalation. View CVE Details Affected Products Hydro-Québec Le Circuit Electrique charging station backend Vendor: Hydro-Québec Product Version: Hydro-Québec Le Circuit Electrique charging station backend: <June_2026 Product Status: known_affected Remediations Mitigation Hydro-Québec has updated the majority of charging stations to disable OCPP, mitigating the risk of…
Source published · CISA Cybersecurity Advisory

Labcenter Proteus 9

View CSAF Summary Successful exploitation of these vulnerabilities could disclose information and allow a malicious user to execute arbitrary code on affected installations. The following versions of Labcenter Proteus 9 are affected: Proteus 9.1_SP4_Build_42914 CVSS Vendor Equipment Vulnerabilities v3 7.8 Labcenter Electronics Labcenter Proteus 9 Out-of-bounds Write, Stack-based Buffer Overflow, Use After Free…
Read more of the source summary
Background Critical Infrastructure Sectors: Communications, Critical Manufacturing, Defense Industrial Base, Energy, Healthcare and Public Health, Transportation Systems, Water and Wastewater Countries/Areas Deployed: Worldwide Company Headquarters Location: United Kingdom Vulnerabilities Expand All + CVE-2026-42953 The application contains an out-of-bounds write vulnerability that can be exploited by an attacker to cause the program to write data past the end of an allocated memory buffer. This can lead to arbitrary code execution. View CVE Details Affected Products Labcenter Proteus 9 Vendor: Labcenter Electronics Product Version: Labcenter Electronics Proteus: 9.1_SP4_Build_42914 Product Status: known_affected Remediations Vendor fix Labcenter recommends ensuring you are…
Source published · CISA Cybersecurity Advisory

Siemens Mendix Studio Pro

View CSAF Summary Mendix Studio Pro versions before V11.12 are affected by a file parsing vulnerability that could be triggered when the application reads specially crafted malicious project during the build pipeline. This could allow an attacker to execute arbitrary code in the context of that user. Siemens has released new versions for several affected products and recommends to update to the latest versions.…
Read more of the source summary
Siemens is preparing further fix versions and recommends countermeasures for products where fixes are not, or not yet available. The following versions of Siemens Mendix Studio Pro are affected: Mendix Studio Pro 10.11 vers:all/* Mendix Studio Pro 10.12 vers:all/* Mendix Studio Pro 10.13 vers:all/* Mendix Studio Pro 10.14 vers:all/* Mendix Studio Pro 10.15 vers:all/* Mendix Studio Pro 10.16 vers:all/* Mendix Studio Pro 10.17 vers:all/* Mendix Studio Pro 10.18 vers:all/* Mendix Studio Pro 10.19 vers:all/* Mendix Studio Pro 10.20 vers:all/* Mendix Studio Pro 10.21 vers:all/* Mendix Studio Pro 10.22 vers:all/* Mendix Studio Pro 10.23 vers:all/* Mendix Studio Pro 10.24 vers:intdot/<10.24.21 Mendix Studio Pro 11.0 vers:all/* Mendix Studio Pro 11.1 vers:all/* Mendix Studio Pro…
Source published · CISA Cybersecurity Advisory

Hitachi Energy e-mesh EMS

View CSAF Summary Hitachi Energy is aware of a buffer overflow vulnerability that affects e-mesh EMS product versions listed in this document. Successful exploitation of this vulnerability could lead to a buffer overflow condition, potentially resulting in application outages (denial of service) and possible arbitrary code execution. Please refer to the Recommended Immediate Actions for information about the…
Read more of the source summary
mitigation/remediation. The following versions of Hitachi Energy e-mesh EMS are affected: Hitachi Energy e-mesh EMS 4.1.6, 4.4.2, 4.7.0 CVSS Vendor Equipment Vulnerabilities v3 8.1 Hitachi Energy Hitachi Energy e-mesh EMS Heap-based Buffer Overflow Background Critical Infrastructure Sectors: Energy Countries/Areas Deployed: Worldwide Company Headquarters Location: Switzerland Vulnerabilities Expand All + CVE-2026-42945 NGINX Plus and NGINX Open Source used in e-mesh EMS have a vulnerability in the ngx_http_rewrite_module module. This vulnerability exists when the rewrite directive is followed by a rewrite, if, or set directive and an unnamed Perl-Compatible Regular Expression (PCRE) capture (for example, $1, $2) with a replacement string that includes a question mark (?). An…
Source published · CISA Cybersecurity Advisory

Hitachi Energy PROMOD V

View CSAF Summary Hitachi Energy is aware of insecure HTTP transmission vulnerability in PROMOD V product versions listed in this document. This vulnerability could allow attackers to intercept or manipulate sensitive data in transit, potentially leading to credential theft, session hijacking, or unauthorized access. The following versions of Hitachi Energy PROMOD V are affected: PROMOD V vers:PROMOD_V/<=1.0.10 CVSS…
Read more of the source summary
Vendor Equipment Vulnerabilities v3 7.1 Hitachi Energy Hitachi Energy PROMOD V Reliance on HTTP instead of HTTPS Background Critical Infrastructure Sectors: Energy Countries/Areas Deployed: Worldwide Company Headquarters Location: Switzerland Vulnerabilities Expand All + CVE-2026-10763 PROMOD V is using insecure HTTP communication instead of HTTPS. The vulnerability is due to the lack of HTTPS support from 3rd party Digipede server. View CVE Details Affected Products Hitachi Energy PROMOD V Vendor: Hitachi Energy Product Version: PROMOD V versions 1.0.10 and prior Product Status: known_affected Remediations Vendor fix Upgrade to version 1.0.11 and enable HTTPS on Digipede server. [2] Refer to “1.0.11 PROMOD V User Guide”, Section 2 Essential Skills->Running PROMOD…
Browse saved snapshots

How to read the archive

Who published the report?

BioThreat brings together reports from the listed public sources. Open the linked title to read the publisher’s original report and any later corrections. Third-party reports retain their own rights and licenses.

Read the source attribution policy

What does each date mean?

A source date is the date the publisher issued or updated a report. A snapshot date is the day BioThreat collected a copy of the feed. The same report can appear in multiple snapshots, and some days have no saved copy.

Browse current public feeds

How can I use the records?

Open a feed or saved snapshot for original links and machine-readable JSON, where available. Use MERIDIAN to compare reporting across sources and dates.

Explore reports in MERIDIAN

Use the Briefing Builder to combine source-linked records with your own analysis and download a report. See a worked food recall briefing.

Build a MERIDIAN briefing