Historical snapshot · Cybersecurity

CISA Advisories

Cybersecurity advisories and mitigation guidance for networks and critical infrastructure.

This page is an archived snapshot of the CISA Advisories feed collected on Jul 20, 2026, preserved by BioThreat Corporation. Publication dates belong to the original source; this snapshot is not a current advisory.
30 recordsOfficial source · JSON
· CISA Cybersecurity Advisory

CISA Adds Two Known Exploited Vulnerabilities to Catalog

CISA has added two new vulnerabilities to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-48939 iCagenda Unrestricted Upload of File with Dangerous Type Vulnerability CVE-2026-56291 Balbooa Forms Unrestricted Upload of File with Dangerous Type Vulnerability These types of vulnerabilities are a frequent attack vector for malicious cyber actors and pose significant…
Read full source summary
CISA has added two new vulnerabilities to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-48939 iCagenda Unrestricted Upload of File with Dangerous Type Vulnerability CVE-2026-56291 Balbooa Forms Unrestricted Upload of File with Dangerous Type Vulnerability These types of vulnerabilities are a frequent attack vector for malicious cyber actors and pose significant risks to the federal enterprise. Binding Operational Directive (BOD) 26-04: Prioritizing Security Updates Based on Risk establishes vulnerability management requirements for Federal Civilian Executive Branch (FCEB) agencies. BOD 26-04 reinforces the importance of the KEV Catalog and requires federal agencies to prioritize rapid remediation of high-risk vulnerabilities, specifically those identified by Common Vulnerabilities and Exposures (CVEs) listed in CISA’s KEV Catalog on publicly exposed assets that grant total control of the asset post-exploitation, while deferring action for lower-risk vulnerabilities. BOD 26-04 further establishes basic expectations for when agencies must check whether threat actors compromised the system before the patch was applied. While BOD 26-04 applies only to FCEB agencies, CISA encourages all organizations to adopt risk-based vulnerability management and prioritize remediation of KEV Catalog vulnerabilities. CISA will continue to add vulnerabilities to the catalog that meet the specified criteria. Aware of an exploited vulnerability not currently listed in the KEV Catalog? Submit it for potential addition through CISA’s KEV Nomination Form. Potential KEV additions must have a CVE ID, evidence of exploitation, and clear mitigation guidance.
· CISA Cybersecurity Advisory

OpenPLC v3

View CSAF Summary Successful exploitation of this vulnerability could allow an authenticated attacker to write arbitrary files to the filesystem and escalate this into arbitrary native code execution through the normal OpenPLC program compilation process, potentially resulting in code execution as the OpenPLC runtime user. The following versions of OpenPLC v3 are affected: OpenPLC v3 CVSS Vendor Equipment…
Read full source summary
View CSAF Summary Successful exploitation of this vulnerability could allow an authenticated attacker to write arbitrary files to the filesystem and escalate this into arbitrary native code execution through the normal OpenPLC program compilation process, potentially resulting in code execution as the OpenPLC runtime user. The following versions of OpenPLC v3 are affected: OpenPLC v3 CVSS Vendor Equipment Vulnerabilities v3 9.9 OpenPLC OpenPLC v3 External Control of File Name or Path Background Critical Infrastructure Sectors: Critical Manufacturing, Energy, Transportation Systems, Water and Wastewater Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2026-14480 OpenPLC Runtime v3 contains an authenticated arbitrary file write vulnerability in the legacy web UI program‑upload workflow. The application stores an attacker‑supplied filename (prog_file) directly into the Programs.File database field and later uses this value as the destination path for an uploaded file without validating or restricting the path. Because Python os.path.join() honors attacker‑controlled absolute paths, an authenticated user can write arbitrary files anywhere writable by the OpenPLC webserver process. In the default build pipeline, all C++ source files within the OpenPLC runtime core directory are automatically compiled into the executable runtime binary. By writing a malicious .cpp file into this directory, an authenticated attacker can escalate the arbitrary file write into arbitrary native code execution when the operator triggers a normal program compilation and runtime start. View CVE Details Affected Products OpenPLC v3 Vendor: OpenPLC Product Version: OpenPLC OpenPLC: v3 Product Status: known_affected Remediations Vendor fix OpenPLC recommends users upgrade to OpenPLC v4 as OpenPLC v3 is end-of-life and is no longer receiving patches, bug fixes, or security updates. Relevant CWE: CWE-73 External Control of File Name or Path Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.9 CRITICAL CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H 4.0 8.7 HIGH CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N Acknowledgments Grady DeRosa reported this vulnerability to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. Revision History Initial Release Date: 2026-07-09 Date Revision Summary 2026-07-09 1 Initial Publication Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Schneider Electric Easergy MiCOM Px40 Series

View CSAF Summary Schneider Electric is aware of a vulnerability in its Easergy MiCOM Px40 Series products. The [Easergy MiCOM Px40](https://www.se.com/ww/en/product-subcategory/4725-easergy-micom-px40-series/?filter=business-6-medium-voltage-distribution-and-grid-automation) is a protection relay series for Medium Voltage, High Voltage and Extra High Voltage protection. Failure to apply the mitigations provided…
Read full source summary
View CSAF Summary Schneider Electric is aware of a vulnerability in its Easergy MiCOM Px40 Series products. The [Easergy MiCOM Px40](https://www.se.com/ww/en/product-subcategory/4725-easergy-micom-px40-series/?filter=business-6-medium-voltage-distribution-and-grid-automation) is a protection relay series for Medium Voltage, High Voltage and Extra High Voltage protection. Failure to apply the mitigations provided below may risk unauthorized exposure of basic device identification through the SNMP protocol. The following versions of Schneider Electric Easergy MiCOM Px40 Series are affected: Easergy MiCOM P14x All versions prior to B4A Easergy MiCOM P24x All versions prior to D3A Easergy MiCOM P341 All versions prior to E3F Easergy MiCOM P342, P343, P344, P345 All versions prior to B3F Easergy MiCOM P442, P444 All versions prior to E3A Easergy MiCOM P443, P445, P446, P543, P544, P545, P546 All versions prior to H6A Easergy MiCOM P841 All versions prior to G6A Easergy MiCOM P643 All versions prior to B3F Easergy MiCOM P642, P645 All versions prior to B4A Easergy MiCOM P741, P742, P743 All versions prior to B2A Easergy MiCOM P746 All versions prior to B4E Easergy MiCOM P746 All versions prior to C4E Easergy MiCOM P849 All versions prior to B4A CVSS Vendor Equipment Vulnerabilities v3 5.3 Schneider Electric Schneider Electric Easergy MiCOM Px40 Series Use of Hard-coded Credentials Background Critical Infrastructure Sectors: Critical Manufacturing, Energy, Transportation Systems Countries/Areas Deployed: Worldwide Company Headquarters Location: France Vulnerabilities Expand All + CVE-2026-4832 CWE-798 Use of Hard-coded Credentials vulnerability exists that could cause unauthorized access to sensitive device information when an unauthenticated attacker is able to interrogate the SNMP port. View CVE Details Affected Products Schneider Electric Easergy MiCOM Px40 Series Vendor: Schneider Electric Product Version: Easergy MiCOM P14x All versions prior to B4A, Easergy MiCOM P24x All versions prior to D3A, Easergy MiCOM P341 All versions prior to E3F, Easergy MiCOM P342, P343, P344, P345 All versions prior to B3F, Easergy MiCOM P442 P444 All versions prior to E3A, Easergy MiCOM P443, P445, P446, P543, P544, P545, P546 All versions prior to H6A, Easergy MiCOM P841 All versions prior to G6A, Easergy MiCOM P643 All versions prior to B3F, Easergy MiCOM P642, P645 All versions prior to B4A, Easergy MiCOM P741, P742, P743 All versions prior to B2A, Easergy MiCOM P746 All versions prior to B4E, Easergy MiCOM P746 All versions prior to C4E, Easergy MiCOM P849 All versions prior to B4A Product Status: known_affected Remediations Mitigation For customers who do not require SNMP Contact Schneider Electric's [Customer Care Center](https://www.se.com/ww/en/work/support/contacts.jsp) to upgrade the Firmware to a version without SNMP functionality. If customers choose not to apply the upgrade provided above, they should immediately apply the following mitigations to reduce the risk of exploit: * Use relays only in a protected network environment, * Use firewalls to protect and separate the control system network from other networks, * Use VPN (Virtual Private Networks) tunnels if remote access is required. For customers who require SNMP Please immediately apply the following mitigations to reduce the risk of exploit: * Use relays only in a protected network environment, * Use firewalls to protect and separate the control system network from other networks, * Use VPN (Virtual Private Networks) tunnels if remote access is required. Relevant CWE: CWE-798 Use of Hard-coded Credentials Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.3 MEDIUM CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N Acknowledgments Schneider Electric CPCERT reported this vulnerability to CISA. General Security Recommendations We strongly recommend the following industry cybersecurity best practices. * Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network. * Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks. * Place all controllers in locked cabinets and never leave them in the “Program” mode. * Never connect programming software to any network other than the network intended for that device. * Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks. * Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation. * Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet. * When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices. For more information refer to the Schneider Electric [Recommended Cybersecurity Best Practices](https://www.se.com/us/en/download/document/7EN52-0390/) document. For More Information This document provides an overview of the identified vulnerability or vulnerabilities and actions required to mitigate. For more details and assistance on how to protect your installation, contact your local Schneider Electric representative or Schneider Electric Industrial Cybersecurity Services: https://www.se.com/ww/en/work/solutions/cybersecurity/. These organizations will be fully aware of this situation and can support you through the process. For further information related to cybersecurity in Schneider Electric's products, visit the company's cybersecurity support portal page: https://www.se.com/ww/en/work/support/cybersecurity/overview.jsp LEGAL DISCLAIMER THIS NOTIFICATION DOCUMENT, THE INFORMATION CONTAINED HEREIN, AND ANY MATERIALS LINKED FROM IT (COLLECTIVELY, THIS “NOTIFICATION”) ARE INTENDED TO HELP PROVIDE AN OVERVIEW OF THE IDENTIFIED SITUATION AND SUGGESTED MITIGATION ACTIONS, REMEDIATION, FIX, AND/OR GENERAL SECURITY RECOMMENDATIONS AND IS PROVIDED ON AN “AS-IS” BASIS WITHOUT WARRANTY OR GUARANTEE OF ANY KIND. SCHNEIDER ELECTRIC DISCLAIMS ALL WARRANTIES RELATING TO THIS NOTIFICATION, EITHER EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. SCHNEIDER ELECTRIC MAKES NO WARRANTY THAT THE NOTIFICATION WILL RESOLVE THE IDENTIFIED SITUATION. IN NO EVENT SHALL SCHNEIDER ELECTRIC BE LIABLE FOR ANY DAMAGES OR LOSSES WHATSOEVER IN CONNECTION WITH THIS NOTIFICATION, INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF SCHNEIDER ELECTRIC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. YOUR USE OF THIS NOTIFICATION IS AT YOUR OWN RISK, AND YOU ARE SOLELY LIABLE FOR ANY DAMAGES TO YOUR SYSTEMS OR ASSETS OR OTHER LOSSES THAT MAY RESULT FROM YOUR USE OF THIS NOTIFICATION. SCHNEIDER ELECTRIC RESERVES THE RIGHT TO UPDATE OR CHANGE THIS NOTIFICATION AT ANY TIME AND IN ITS SOLE DISCRETION About Schneider Electric Schneider's purpose is to create Impact by empowering all to make the most of our energy and resources, bridging progress and sustainability for all. We call this Life Is On. Our mission is to be the trusted partner in Sustainability and Efficiency. We are a global industrial technology leader bringing world-leading expertise in electrification, automation and digitization to smart industries, resilient infrastructure, future-proof data centers, intelligent buildings, and intuitive homes. Anchored by our deep domain expertise, we provide integrated end-to-end lifecycle AI enabled Industrial IoT solutions with connected products, automation, software and services, delivering digital twins to enable profitable growth for our customers. We are a people company with an ecosystem of 150,000 colleagues and more than a million partners operating in over 100 countries to ensure proximity to our customers and stakeholders. We embrace diversity and inclusion in everything we do, guided by our meaningful purpose of a sustainable future for all. www.se.com Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Schneider Electric CPCERT SEVD-2026-104-03 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Schneider Electric CPCERT directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-04-14 Date Revision Summary 2026-04-14 1 Original Release 2026-05-12 2 Updated the risk associated with successful exploitation of this vulnerability and revised the remediation table to a mitigation table to emphasize that multiple mitigation options are available. 2026-07-09 3 Initial CISA Republication of Schneider Electric CPCERT SEVD-2026-104-03 advisory Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Schneider Electric PowerChute Serial Shutdown

View CSAF Summary Successful exploitation of these vulnerabilities could allow attackers to overwrite critical files, forge or inject malicious log data, gain unauthorized account access, trigger denial‑of‑service conditions, truncate or alter logging information, reset user credentials, or expose sensitive information. The following versions of Schneider Electric PowerChute Serial Shutdown are affected: PowerChute…
Read full source summary
View CSAF Summary Successful exploitation of these vulnerabilities could allow attackers to overwrite critical files, forge or inject malicious log data, gain unauthorized account access, trigger denial‑of‑service conditions, truncate or alter logging information, reset user credentials, or expose sensitive information. The following versions of Schneider Electric PowerChute Serial Shutdown are affected: PowerChute Serial Shutdown <=1.4 CVSS Vendor Equipment Vulnerabilities v3 6.1 SuSE, Schneider Electric, Red Hat, Microsoft Schneider Electric PowerChute Serial Shutdown Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal'), Improper Encoding or Escaping of Output, Improper Restriction of Excessive Authentication Attempts, Uncontrolled Resource Consumption, Improper Validation of Specified Quantity in Input, Improper Neutralization of CRLF Sequences ('CRLF Injection'), Insertion of Sensitive Information into Log File Background Critical Infrastructure Sectors: Communications, Critical Manufacturing, Energy, Healthcare and Public Health, Information Technology, Transportation Systems Countries/Areas Deployed: Worldwide Company Headquarters Location: France Vulnerabilities Expand All + CVE-2026-2399 PowerChute is vulnerable to improper restriction of file paths, which could allow critical system files to be overwritten with unintended data. View CVE Details Affected Products Schneider Electric PowerChute Serial Shutdown Vendor: SuSE, Schneider Electric, Red Hat, Microsoft Product Version: SuSE, Schneider Electric, Red Hat, Microsoft PowerChute Serial Shutdown: <=1.4 Product Status: known_affected Remediations Vendor fix SuSE, Schneider Electric, Red Hat, and Microsoft have identified the following specific workarounds and mitigations users can apply to reduce risk: (CVE-2026-2399, CVE-2026-2404, CVE-2026-2405, CVE-2026-2403, CVE-2026-2400, CVE-2026-2401) PowerChute Serial Shutdown Versions 1.4 and prior: Version 1.5 of PowerChute Serial Shutdown includes a fix for this vulnerability and is available for download here: Windows (https://www.se.com/ww/en/download/document/SPD-PCSS_WIN_EN/). Linux (https://www.se.com/ww/en/download/document/SPD-PCSS_LNX_EN/). https://www.se.com/ww/en/download/document/SPD-PCSS_WIN_EN/ Vendor fix SuSE, Schneider Electric, Red Hat, and Microsoft have identified the following specific workarounds and mitigations users can apply to reduce risk: (CVE-2026-2399, CVE-2026-2404, CVE-2026-2405, CVE-2026-2403, CVE-2026-2400, CVE-2026-2401) PowerChute Serial Shutdown Versions 1.4 and prior: Version 1.5 of PowerChute Serial Shutdown includes a fix for this vulnerability and is available for download here: Windows (https://www.se.com/ww/en/download/document/SPD-PCSS_WIN_EN/). Linux (https://www.se.com/ww/en/download/document/SPD-PCSS_LNX_EN/). https://www.se.com/ww/en/download/document/SPD-PCSS_LNX_EN/ Mitigation Specific instructions and hardening guidelines for these mitigations can be found in the Security Handbook. https://download.schneider-electric.com/files?p_Doc_Ref=SPD_CCON-PCSSSH_EN Vendor fix The following product versions have been fixed: PowerChute Serial Shutdown Version 1.5 installed on Microsoft Windows are fixed versions for CVE-2026-2399. Vendor fix PowerChute Serial Shutdown Version 1.5 installed on Red Hat Enterprise Linux are fixed versions for CVE-2026-2399. Vendor fix PowerChute Serial Shutdown Version 1.5 installed on SuSE Linux are fixed versions for CVE-2026-2399. Vendor fix For more information see the associated Schneider Electric CPCERT security advisory SEVD-2026-104-01 Multiple Vulnerabilities on PowerChute Serial Shutdown - SEVD-2026-104-01 PDF Version (https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-104-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-104-01.pdf). Multiple Vulnerabilities on PowerChute Serial Shutdown- SEVD-2026-104-01 CSAF Version (https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-104-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=sevd-2026-104-01.json). https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-104-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-104-01.pdf Vendor fix For more information see the associated Schneider Electric CPCERT security advisory SEVD-2026-104-01 Multiple Vulnerabilities on PowerChute Serial Shutdown - SEVD-2026-104-01 PDF Version (https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-104-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-104-01.pdf). Multiple Vulnerabilities on PowerChute Serial Shutdown- SEVD-2026-104-01 CSAF Version (https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-104-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=sevd-2026-104-01.json). https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-104-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=sevd-2026-104-01.json Relevant CWE: CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.1 MEDIUM CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:H 4.0 6.9 MEDIUM CVSS:4.0/AV:A/AC:L/AT:N/PR:H/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N CVE-2026-2404 PowerChute is vulnerable to improper output encoding, which may allow crafted input to be reflected in log files in unexpected ways. View CVE Details Affected Products Schneider Electric PowerChute Serial Shutdown Vendor: SuSE, Schneider Electric, Red Hat, Microsoft Product Version: SuSE, Schneider Electric, Red Hat, Microsoft PowerChute Serial Shutdown: <=1.4 Product Status: known_affected Remediations Vendor fix SuSE, Schneider Electric, Red Hat, and Microsoft have identified the following specific workarounds and mitigations users can apply to reduce risk: (CVE-2026-2399, CVE-2026-2404, CVE-2026-2405, CVE-2026-2403, CVE-2026-2400, CVE-2026-2401) PowerChute Serial Shutdown Versions 1.4 and prior: Version 1.5 of PowerChute Serial Shutdown includes a fix for this vulnerability and is available for download here: Windows (https://www.se.com/ww/en/download/document/SPD-PCSS_WIN_EN/). Linux (https://www.se.com/ww/en/download/document/SPD-PCSS_LNX_EN/). https://www.se.com/ww/en/download/document/SPD-PCSS_WIN_EN/ Vendor fix SuSE, Schneider Electric, Red Hat, and Microsoft have identified the following specific workarounds and mitigations users can apply to reduce risk: (CVE-2026-2399, CVE-2026-2404, CVE-2026-2405, CVE-2026-2403, CVE-2026-2400, CVE-2026-2401) PowerChute Serial Shutdown Versions 1.4 and prior: Version 1.5 of PowerChute Serial Shutdown includes a fix for this vulnerability and is available for download here: Windows (https://www.se.com/ww/en/download/document/SPD-PCSS_WIN_EN/). Linux (https://www.se.com/ww/en/download/document/SPD-PCSS_LNX_EN/). https://www.se.com/ww/en/download/document/SPD-PCSS_LNX_EN/ Mitigation Specific instructions and hardening guidelines for these mitigations can be found in the Security Handbook. https://download.schneider-electric.com/files?p_Doc_Ref=SPD_CCON-PCSSSH_EN Vendor fix PowerChute Serial Shutdown Version 1.5 installed on Microsoft Windows are fixed versions for CVE-2026-2404. Vendor fix PowerChute Serial Shutdown Version 1.5 installed on Red Hat Enterprise Linux are fixed versions for CVE-2026-2404. Vendor fix PowerChute Serial Shutdown Version 1.5 installed on SuSE Linux are fixed versions for CVE-2026-2404. Vendor fix For more information see the associated Schneider Electric CPCERT security advisory SEVD-2026-104-01 Multiple Vulnerabilities on PowerChute Serial Shutdown - SEVD-2026-104-01 PDF Version (https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-104-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-104-01.pdf). Multiple Vulnerabilities on PowerChute Serial Shutdown- SEVD-2026-104-01 CSAF Version (https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-104-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=sevd-2026-104-01.json). https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-104-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-104-01.pdf Vendor fix For more information see the associated Schneider Electric CPCERT security advisory SEVD-2026-104-01 Multiple Vulnerabilities on PowerChute Serial Shutdown - SEVD-2026-104-01 PDF Version (https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-104-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-104-01.pdf). Multiple Vulnerabilities on PowerChute Serial Shutdown- SEVD-2026-104-01 CSAF Version (https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-104-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=sevd-2026-104-01.json). https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-104-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=sevd-2026-104-01.json Relevant CWE: CWE-116 Improper Encoding or Escaping of Output Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.3 MEDIUM CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N 4.0 6.9 MEDIUM CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N CVE-2026-2402 PowerChute is vulnerable to insufficient limitations on repeated authentication attempts across multiple endpoints. View CVE Details Affected Products Schneider Electric PowerChute Serial Shutdown Vendor: SuSE, Schneider Electric, Red Hat, Microsoft Product Version: SuSE, Schneider Electric, Red Hat, Microsoft PowerChute Serial Shutdown: <=1.4 Product Status: known_affected Remediations Vendor fix (CVE-2026-2402) PowerChute Serial Shutdown Versions 1.4 and prior: Version 1.5 of PowerChute Serial Shutdown includes a fix for this vulnerability and is available for download here: Windows (https://www.se.com/ww/en/download/document/SPD-PCSS_WIN_EN/). Linux (https://www.se.com/ww/en/download/document/SPD-PCSS_LNX_EN/). https://www.se.com/ww/en/download/document/SPD-PCSS_WIN_EN/ Vendor fix (CVE-2026-2402) PowerChute Serial Shutdown Versions 1.4 and prior: Version 1.5 of PowerChute Serial Shutdown includes a fix for this vulnerability and is available for download here: Windows (https://www.se.com/ww/en/download/document/SPD-PCSS_WIN_EN/). Linux (https://www.se.com/ww/en/download/document/SPD-PCSS_LNX_EN/). https://www.se.com/ww/en/download/document/SPD-PCSS_LNX_EN/ Mitigation Specific instructions and hardening guidelines for these mitigations can be found in the Security Handbook. https://download.schneider-electric.com/files?p_Doc_Ref=SPD_CCON-PCSSSH_EN Vendor fix PowerChute Serial Shutdown Version 1.5 installed on Microsoft Windows are fixed versions for CVE-2026-2402. Vendor fix PowerChute Serial Shutdown Version 1.5 installed on Red Hat Enterprise Linux are fixed versions for CVE-2026-2402. Vendor fix PowerChute Serial Shutdown Version 1.5 installed on SuSE Linux are fixed versions for CVE-2026-2402. Vendor fix For more information see the associated Schneider Electric CPCERT security advisory SEVD-2026-104-01 Multiple Vulnerabilities on PowerChute Serial Shutdown - SEVD-2026-104-01 PDF Version (https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-104-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-104-01.pdf). Multiple Vulnerabilities on PowerChute Serial Shutdown- SEVD-2026-104-01 CSAF Version (https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-104-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=sevd-2026-104-01.json). https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-104-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-104-01.pdf Vendor fix For more information see the associated Schneider Electric CPCERT security advisory SEVD-2026-104-01 Multiple Vulnerabilities on PowerChute Serial Shutdown - SEVD-2026-104-01 PDF Version (https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-104-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-104-01.pdf). Multiple Vulnerabilities on PowerChute Serial Shutdown- SEVD-2026-104-01 CSAF Version (https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-104-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=sevd-2026-104-01.json). https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-104-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=sevd-2026-104-01.json Relevant CWE: CWE-307 Improper Restriction of Excessive Authentication Attempts Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.3 MEDIUM CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L 4.0 6.9 MEDIUM CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N CVE-2026-2405 PowerChute is vulnerable to uncontrolled resource consumption when certain system operations are triggered excessively. View CVE Details Affected Products Schneider Electric PowerChute Serial Shutdown Vendor: SuSE, Schneider Electric, Red Hat, Microsoft Product Version: SuSE, Schneider Electric, Red Hat, Microsoft PowerChute Serial Shutdown: <=1.4 Product Status: known_affected Remediations Vendor fix SuSE, Schneider Electric, Red Hat, and Microsoft have identified the following specific workarounds and mitigations users can apply to reduce risk: (CVE-2026-2399, CVE-2026-2404, CVE-2026-2405, CVE-2026-2403, CVE-2026-2400, CVE-2026-2401) PowerChute Serial Shutdown Versions 1.4 and prior: Version 1.5 of PowerChute Serial Shutdown includes a fix for this vulnerability and is available for download here: Windows (https://www.se.com/ww/en/download/document/SPD-PCSS_WIN_EN/). Linux (https://www.se.com/ww/en/download/document/SPD-PCSS_LNX_EN/). https://www.se.com/ww/en/download/document/SPD-PCSS_WIN_EN/ Vendor fix SuSE, Schneider Electric, Red Hat, and Microsoft have identified the following specific workarounds and mitigations users can apply to reduce risk: (CVE-2026-2399, CVE-2026-2404, CVE-2026-2405, CVE-2026-2403, CVE-2026-2400, CVE-2026-2401) PowerChute Serial Shutdown Versions 1.4 and prior: Version 1.5 of PowerChute Serial Shutdown includes a fix for this vulnerability and is available for download here: Windows (https://www.se.com/ww/en/download/document/SPD-PCSS_WIN_EN/). Linux (https://www.se.com/ww/en/download/document/SPD-PCSS_LNX_EN/). https://www.se.com/ww/en/download/document/SPD-PCSS_LNX_EN/ Mitigation Specific instructions and hardening guidelines for these mitigations can be found in the Security Handbook. https://download.schneider-electric.com/files?p_Doc_Ref=SPD_CCON-PCSSSH_EN Vendor fix PowerChute Serial Shutdown Version 1.5 installed on Microsoft Windows are fixed versions for CVE-2026-2405. Vendor fix PowerChute Serial Shutdown Version 1.5 installed on Red Hat Enterprise Linux are fixed versions for CVE-2026-2405. Vendor fix PowerChute Serial Shutdown Version 1.5 installed on SuSE Linux are fixed versions for CVE-2026-2405. Vendor fix For more information see the associated Schneider Electric CPCERT security advisory SEVD-2026-104-01 Multiple Vulnerabilities on PowerChute Serial Shutdown - SEVD-2026-104-01 PDF Version (https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-104-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-104-01.pdf). Multiple Vulnerabilities on PowerChute Serial Shutdown- SEVD-2026-104-01 CSAF Version (https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-104-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=sevd-2026-104-01.json). https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-104-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-104-01.pdf Vendor fix For more information see the associated Schneider Electric CPCERT security advisory SEVD-2026-104-01 Multiple Vulnerabilities on PowerChute Serial Shutdown - SEVD-2026-104-01 PDF Version (https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-104-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-104-01.pdf). Multiple Vulnerabilities on PowerChute Serial Shutdown- SEVD-2026-104-01 CSAF Version (https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-104-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=sevd-2026-104-01.json). https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-104-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=sevd-2026-104-01.json Relevant CWE: CWE-400 Uncontrolled Resource Consumption Metrics CVSS Version Base Score Base Severity Vector String 3.1 4.3 MEDIUM CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:L 4.0 5.3 MEDIUM CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N CVE-2026-2403 PowerChute is vulnerable to improper validation of quantity‑related inputs, which can cause event and data logs to be truncated. As a result, important audit information may be lost, reducing visibility into system behavior. View CVE Details Affected Products Schneider Electric PowerChute Serial Shutdown Vendor: SuSE, Schneider Electric, Red Hat, Microsoft Product Version: SuSE, Schneider Electric, Red Hat, Microsoft PowerChute Serial Shutdown: <=1.4 Product Status: known_affected Remediations Vendor fix SuSE, Schneider Electric, Red Hat, and Microsoft have identified the following specific workarounds and mitigations users can apply to reduce risk: (CVE-2026-2399, CVE-2026-2404, CVE-2026-2405, CVE-2026-2403, CVE-2026-2400, CVE-2026-2401) PowerChute Serial Shutdown Versions 1.4 and prior: Version 1.5 of PowerChute Serial Shutdown includes a fix for this vulnerability and is available for download here: Windows (https://www.se.com/ww/en/download/document/SPD-PCSS_WIN_EN/). Linux (https://www.se.com/ww/en/download/document/SPD-PCSS_LNX_EN/). https://www.se.com/ww/en/download/document/SPD-PCSS_WIN_EN/ Vendor fix SuSE, Schneider Electric, Red Hat, and Microsoft have identified the following specific workarounds and mitigations users can apply to reduce risk: (CVE-2026-2399, CVE-2026-2404, CVE-2026-2405, CVE-2026-2403, CVE-2026-2400, CVE-2026-2401) PowerChute Serial Shutdown Versions 1.4 and prior: Version 1.5 of PowerChute Serial Shutdown includes a fix for this vulnerability and is available for download here: Windows (https://www.se.com/ww/en/download/document/SPD-PCSS_WIN_EN/). Linux (https://www.se.com/ww/en/download/document/SPD-PCSS_LNX_EN/). https://www.se.com/ww/en/download/document/SPD-PCSS_LNX_EN/ Mitigation Specific instructions and hardening guidelines for these mitigations can be found in the Security Handbook. https://download.schneider-electric.com/files?p_Doc_Ref=SPD_CCON-PCSSSH_EN Vendor fix PowerChute Serial Shutdown Version 1.5 installed on Microsoft Windows are fixed versions for CVE-2026-2403. Vendor fix PowerChute Serial Shutdown Version 1.5 installed on Red Hat Enterprise Linux are fixed versions for CVE-2026-2403. Vendor fix PowerChute Serial Shutdown Version 1.5 installed on SuSE Linux are fixed versions for CVE-2026-2403. Vendor fix For more information see the associated Schneider Electric CPCERT security advisory SEVD-2026-104-01 Multiple Vulnerabilities on PowerChute Serial Shutdown - SEVD-2026-104-01 PDF Version (https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-104-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-104-01.pdf). Multiple Vulnerabilities on PowerChute Serial Shutdown- SEVD-2026-104-01 CSAF Version (https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-104-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=sevd-2026-104-01.json). https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-104-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-104-01.pdf Vendor fix For more information see the associated Schneider Electric CPCERT security advisory SEVD-2026-104-01 Multiple Vulnerabilities on PowerChute Serial Shutdown - SEVD-2026-104-01 PDF Version (https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-104-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-104-01.pdf). Multiple Vulnerabilities on PowerChute Serial Shutdown- SEVD-2026-104-01 CSAF Version (https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-104-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=sevd-2026-104-01.json). https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-104-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=sevd-2026-104-01.json Relevant CWE: CWE-1284 Improper Validation of Specified Quantity in Input Metrics CVSS Version Base Score Base Severity Vector String 3.1 4.3 MEDIUM CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N 4.0 5.3 MEDIUM CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N CVE-2026-2400 PowerChute is vulnerable to improper handling of newline sequences in certain inputs, enabling unexpected modification of configuration‑related data. View CVE Details Affected Products Schneider Electric PowerChute Serial Shutdown Vendor: SuSE, Schneider Electric, Red Hat, Microsoft Product Version: SuSE, Schneider Electric, Red Hat, Microsoft PowerChute Serial Shutdown: <=1.4 Product Status: known_affected Remediations Vendor fix SuSE, Schneider Electric, Red Hat, and Microsoft have identified the following specific workarounds and mitigations users can apply to reduce risk: (CVE-2026-2399, CVE-2026-2404, CVE-2026-2405, CVE-2026-2403, CVE-2026-2400, CVE-2026-2401) PowerChute Serial Shutdown Versions 1.4 and prior: Version 1.5 of PowerChute Serial Shutdown includes a fix for this vulnerability and is available for download here: Windows (https://www.se.com/ww/en/download/document/SPD-PCSS_WIN_EN/). Linux (https://www.se.com/ww/en/download/document/SPD-PCSS_LNX_EN/). https://www.se.com/ww/en/download/document/SPD-PCSS_WIN_EN/ Vendor fix SuSE, Schneider Electric, Red Hat, and Microsoft have identified the following specific workarounds and mitigations users can apply to reduce risk: (CVE-2026-2399, CVE-2026-2404, CVE-2026-2405, CVE-2026-2403, CVE-2026-2400, CVE-2026-2401) PowerChute Serial Shutdown Versions 1.4 and prior: Version 1.5 of PowerChute Serial Shutdown includes a fix for this vulnerability and is available for download here: Windows (https://www.se.com/ww/en/download/document/SPD-PCSS_WIN_EN/). Linux (https://www.se.com/ww/en/download/document/SPD-PCSS_LNX_EN/). https://www.se.com/ww/en/download/document/SPD-PCSS_LNX_EN/ Mitigation Specific instructions and hardening guidelines for these mitigations can be found in the Security Handbook. https://download.schneider-electric.com/files?p_Doc_Ref=SPD_CCON-PCSSSH_EN Vendor fix PowerChute Serial Shutdown Version 1.5 installed on Microsoft Windows are fixed versions for CVE-2026-2400. Vendor fix PowerChute Serial Shutdown Version 1.5 installed on Red Hat Enterprise Linux are fixed versions for CVE-2026-2400. Vendor fix PowerChute Serial Shutdown Version 1.5 installed on SuSE Linux are fixed versions for CVE-2026-2400. Vendor fix For more information see the associated Schneider Electric CPCERT security advisory SEVD-2026-104-01 Multiple Vulnerabilities on PowerChute Serial Shutdown - SEVD-2026-104-01 PDF Version (https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-104-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-104-01.pdf). Multiple Vulnerabilities on PowerChute Serial Shutdown- SEVD-2026-104-01 CSAF Version (https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-104-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=sevd-2026-104-01.json). https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-104-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-104-01.pdf Vendor fix For more information see the associated Schneider Electric CPCERT security advisory SEVD-2026-104-01 Multiple Vulnerabilities on PowerChute Serial Shutdown - SEVD-2026-104-01 PDF Version (https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-104-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-104-01.pdf). Multiple Vulnerabilities on PowerChute Serial Shutdown- SEVD-2026-104-01 CSAF Version (https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-104-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=sevd-2026-104-01.json). https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-104-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=sevd-2026-104-01.json Relevant CWE: CWE-93 Improper Neutralization of CRLF Sequences ('CRLF Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 4.3 MEDIUM CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:L 4.0 5.3 MEDIUM CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N CVE-2026-2401 PowerChute is vulnerable to improper logging of sensitive information when certain user‑triggered operations occur. View CVE Details Affected Products Schneider Electric PowerChute Serial Shutdown Vendor: SuSE, Schneider Electric, Red Hat, Microsoft Product Version: SuSE, Schneider Electric, Red Hat, Microsoft PowerChute Serial Shutdown: <=1.4 Product Status: known_affected Remediations Vendor fix SuSE, Schneider Electric, Red Hat, and Microsoft have identified the following specific workarounds and mitigations users can apply to reduce risk: (CVE-2026-2399, CVE-2026-2404, CVE-2026-2405, CVE-2026-2403, CVE-2026-2400, CVE-2026-2401) PowerChute Serial Shutdown Versions 1.4 and prior: Version 1.5 of PowerChute Serial Shutdown includes a fix for this vulnerability and is available for download here: Windows (https://www.se.com/ww/en/download/document/SPD-PCSS_WIN_EN/). Linux (https://www.se.com/ww/en/download/document/SPD-PCSS_LNX_EN/). https://www.se.com/ww/en/download/document/SPD-PCSS_WIN_EN/ Vendor fix SuSE, Schneider Electric, Red Hat, and Microsoft have identified the following specific workarounds and mitigations users can apply to reduce risk: (CVE-2026-2399, CVE-2026-2404, CVE-2026-2405, CVE-2026-2403, CVE-2026-2400, CVE-2026-2401) PowerChute Serial Shutdown Versions 1.4 and prior: Version 1.5 of PowerChute Serial Shutdown includes a fix for this vulnerability and is available for download here: Windows (https://www.se.com/ww/en/download/document/SPD-PCSS_WIN_EN/). Linux (https://www.se.com/ww/en/download/document/SPD-PCSS_LNX_EN/). https://www.se.com/ww/en/download/document/SPD-PCSS_LNX_EN/ Mitigation Specific instructions and hardening guidelines for these mitigations can be found in the Security Handbook. https://download.schneider-electric.com/files?p_Doc_Ref=SPD_CCON-PCSSSH_EN Vendor fix PowerChute Serial Shutdown Version 1.5 installed on Microsoft Windows are fixed versions for CVE-2026-2401. Vendor fix PowerChute Serial Shutdown Version 1.5 installed on Red Hat Enterprise Linux are fixed versions for CVE-2026-2401. Vendor fix PowerChute Serial Shutdown Version 1.5 installed on SuSE Linux are fixed versions for CVE-2026-2401. Vendor fix For more information see the associated Schneider Electric CPCERT security advisory SEVD-2026-104-01 Multiple Vulnerabilities on PowerChute Serial Shutdown - SEVD-2026-104-01 PDF Version (https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-104-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-104-01.pdf). Multiple Vulnerabilities on PowerChute Serial Shutdown- SEVD-2026-104-01 CSAF Version (https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-104-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=sevd-2026-104-01.json). https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-104-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-104-01.pdf Vendor fix For more information see the associated Schneider Electric CPCERT security advisory SEVD-2026-104-01 Multiple Vulnerabilities on PowerChute Serial Shutdown - SEVD-2026-104-01 PDF Version (https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-104-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-104-01.pdf). Multiple Vulnerabilities on PowerChute Serial Shutdown- SEVD-2026-104-01 CSAF Version (https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-104-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=sevd-2026-104-01.json). https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-104-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=sevd-2026-104-01.json Relevant CWE: CWE-532 Insertion of Sensitive Information into Log File Metrics CVSS Version Base Score Base Severity Vector String 3.1 2.8 LOW CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:L/I:N/A:N 4.0 2.4 LOW CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:P/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N Acknowledgments Schneider Electric reported these vulnerabilities to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs). Recognize VPNs may have vulnerabilities, should be updated to the most recent version available, and are only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. Revision History Initial Release Date: 2026-04-14 Date Revision Summary 2026-04-14 1 Initial Publication 2026-07-09 2 Initial Republication of Schneider Electric CPCERT SEVD-2026-104-01 Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

CISA Adds One Known Exploited Vulnerability to Catalog

CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-48282 Adobe ColdFusion Path Traversal Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 26-04: Prioritizing Security Updates Based on Risk…
Read full source summary
CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-48282 Adobe ColdFusion Path Traversal Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 26-04: Prioritizing Security Updates Based on Risk establishes vulnerability management requirements for Federal Civilian Executive Branch (FCEB) agencies. BOD 26-04 reinforces the importance of the KEV Catalog and requires federal agencies to prioritize rapid remediation of high-risk vulnerabilities, specifically those identified by Common Vulnerabilities and Exposures (CVEs) listed in CISA’s KEV Catalog on publicly exposed assets that grant total control of the asset post-exploitation, while deferring action for lower-risk vulnerabilities. BOD 26-04 further establishes basic expectations for when agencies must check whether threat actors compromised the system before the patch was applied. While BOD 26-04 applies only to FCEB agencies, CISA encourages all organizations to adopt risk-based vulnerability management and prioritize remediation of KEV Catalog vulnerabilities. CISA will continue to add vulnerabilities to the catalog that meet the specified criteria. Aware of an exploited vulnerability not currently listed in the KEV Catalog? Submit it for potential addition through CISA’s KEV Nomination Form. Potential KEV additions must have a CVE ID, evidence of exploitation, and clear mitigation guidance.
· CISA Cybersecurity Advisory

Hydro-Québec Le Circuit Electrique charging station backend

View CSAF Summary Successful exploitation of these vulnerabilities could lead to privilege escalation, or result in a denial-of-service attack. The following versions of Hydro-Québec Le Circuit Electrique charging station backend are affected: Le Circuit Electrique charging station backend CVSS Vendor Equipment Vulnerabilities v3 9.8 Hydro-Québec Hydro-Québec Le Circuit Electrique charging station backend Improper…
Read full source summary
View CSAF Summary Successful exploitation of these vulnerabilities could lead to privilege escalation, or result in a denial-of-service attack. The following versions of Hydro-Québec Le Circuit Electrique charging station backend are affected: Le Circuit Electrique charging station backend CVSS Vendor Equipment Vulnerabilities v3 9.8 Hydro-Québec Hydro-Québec Le Circuit Electrique charging station backend Improper Access Control, Improper Restriction of Excessive Authentication Attempts, Insufficient Session Expiration Background Critical Infrastructure Sectors: Transportation Systems Countries/Areas Deployed: Canada Company Headquarters Location: Canada Vulnerabilities Expand All + CVE-2026-20744 The charging station websocket endpoint accepts connections without proper authentication, which could lead to privilege escalation. View CVE Details Affected Products Hydro-Québec Le Circuit Electrique charging station backend Vendor: Hydro-Québec Product Version: Hydro-Québec Le Circuit Electrique charging station backend: <June_2026 Product Status: known_affected Remediations Mitigation Hydro-Québec has updated the majority of charging stations to disable OCPP, mitigating the risk of exploitation. Hydro-Québec has also implemented authentication systems to mitigate the issue for certain charging stations which are still reliant on OCPP. Contact Hydro-Québec with any additional questions. Relevant CWE: CWE-284 Improper Access Control Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.8 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H 4.0 9.3 CRITICAL CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N CVE-2026-42952 Previously, there was no throttling on repeated authentication attempts to the charging station backend, which could allow an attacker to execute a Denial-of-Service attack. View CVE Details Affected Products Hydro-Québec Le Circuit Electrique charging station backend Vendor: Hydro-Québec Product Version: Hydro-Québec Le Circuit Electrique charging station backend: <June_2026 Product Status: known_affected Remediations Mitigation Hydro-Québec has updated the majority of charging stations to disable OCPP, mitigating the risk of exploitation. Hydro-Québec has also implemented authentication systems to mitigate the issue for certain charging stations which are still reliant on OCPP. Contact Hydro-Québec with any additional questions. Relevant CWE: CWE-307 Improper Restriction of Excessive Authentication Attempts Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H 4.0 8.7 HIGH CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N CVE-2026-44383 Multiple connections to the backend using the same charging station ID are allowed, which could allow an attacker to deploy multiple instances of malicious OCPP clients to overwhelm the backend. View CVE Details Affected Products Hydro-Québec Le Circuit Electrique charging station backend Vendor: Hydro-Québec Product Version: Hydro-Québec Le Circuit Electrique charging station backend: <June_2026 Product Status: known_affected Remediations Mitigation Hydro-Québec has updated the majority of charging stations to disable OCPP, mitigating the risk of exploitation. Hydro-Québec has also implemented authentication systems to mitigate the issue for certain charging stations which are still reliant on OCPP. Contact Hydro-Québec with any additional questions. Relevant CWE: CWE-613 Insufficient Session Expiration Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H 4.0 8.7 HIGH CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N Acknowledgments An anonymous researcher reported these vulnerabilities to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. Revision History Initial Release Date: 2026-07-07 Date Revision Summary 2026-07-07 1 Initial Publication Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Labcenter Proteus 9

View CSAF Summary Successful exploitation of these vulnerabilities could disclose information and allow a malicious user to execute arbitrary code on affected installations. The following versions of Labcenter Proteus 9 are affected: Proteus 9.1_SP4_Build_42914 CVSS Vendor Equipment Vulnerabilities v3 7.8 Labcenter Electronics Labcenter Proteus 9 Out-of-bounds Write, Stack-based Buffer Overflow, Use After Free…
Read full source summary
View CSAF Summary Successful exploitation of these vulnerabilities could disclose information and allow a malicious user to execute arbitrary code on affected installations. The following versions of Labcenter Proteus 9 are affected: Proteus 9.1_SP4_Build_42914 CVSS Vendor Equipment Vulnerabilities v3 7.8 Labcenter Electronics Labcenter Proteus 9 Out-of-bounds Write, Stack-based Buffer Overflow, Use After Free Background Critical Infrastructure Sectors: Communications, Critical Manufacturing, Defense Industrial Base, Energy, Healthcare and Public Health, Transportation Systems, Water and Wastewater Countries/Areas Deployed: Worldwide Company Headquarters Location: United Kingdom Vulnerabilities Expand All + CVE-2026-42953 The application contains an out-of-bounds write vulnerability that can be exploited by an attacker to cause the program to write data past the end of an allocated memory buffer. This can lead to arbitrary code execution. View CVE Details Affected Products Labcenter Proteus 9 Vendor: Labcenter Electronics Product Version: Labcenter Electronics Proteus: 9.1_SP4_Build_42914 Product Status: known_affected Remediations Vendor fix Labcenter recommends ensuring you are using the latest version (9.2 SPO) of the software. Version can be found by looking at the bottom left of the Proteus home page (Version 8 or higher) or by selecting the About ISIS or About ARES option from the Help menu. Update notifications appear in the new and information section of the home page where you can activate the download and installation directly. Mitigation If you have questions or need help please contact Labcenter or your local distributor. Relevant CWE: CWE-787 Out-of-bounds Write Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.8 HIGH CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H 4.0 8.4 HIGH CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N CVE-2026-49033 The application contains a stack-based buffer overflow vulnerability that can be exploited by an attacker to execute arbitrary code. View CVE Details Affected Products Labcenter Proteus 9 Vendor: Labcenter Electronics Product Version: Labcenter Electronics Proteus: 9.1_SP4_Build_42914 Product Status: known_affected Remediations Vendor fix Labcenter recommends ensuring you are using the latest version (9.2 SPO) of the software. Version can be found by looking at the bottom left of the Proteus home page (Version 8 or higher) or by selecting the About ISIS or About ARES option from the Help menu. Update notifications appear in the new and information section of the home page where you can activate the download and installation directly. Mitigation If you have questions or need help please contact Labcenter or your local distributor. Relevant CWE: CWE-121 Stack-based Buffer Overflow Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.8 HIGH CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H 4.0 8.4 HIGH CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N CVE-2026-42958 The application contains a use-after-free vulnerability that can be exploited to cause memory corruption while parsing specially crafted files. This could allow an attacker to execute arbitrary code in the context of the current process. View CVE Details Affected Products Labcenter Proteus 9 Vendor: Labcenter Electronics Product Version: Labcenter Electronics Proteus: 9.1_SP4_Build_42914 Product Status: known_affected Remediations Vendor fix Labcenter recommends ensuring you are using the latest version (9.2 SPO) of the software. Version can be found by looking at the bottom left of the Proteus home page (Version 8 or higher) or by selecting the About ISIS or About ARES option from the Help menu. Update notifications appear in the new and information section of the home page where you can activate the download and installation directly. Mitigation If you have questions or need help please contact Labcenter or your local distributor. Relevant CWE: CWE-416 Use After Free Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.8 HIGH CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H 4.0 8.4 HIGH CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N Acknowledgments Michael Heinzl reported these vulnerabilities to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. These vulnerabilities are not exploitable remotely. Revision History Initial Release Date: 2026-07-07 Date Revision Summary 2026-07-07 1 Initial Publication Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Siemens Mendix Studio Pro

View CSAF Summary Mendix Studio Pro versions before V11.12 are affected by a file parsing vulnerability that could be triggered when the application reads specially crafted malicious project during the build pipeline. This could allow an attacker to execute arbitrary code in the context of that user. Siemens has released new versions for several affected products and recommends to update to the latest versions.…
Read full source summary
View CSAF Summary Mendix Studio Pro versions before V11.12 are affected by a file parsing vulnerability that could be triggered when the application reads specially crafted malicious project during the build pipeline. This could allow an attacker to execute arbitrary code in the context of that user. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends countermeasures for products where fixes are not, or not yet available. The following versions of Siemens Mendix Studio Pro are affected: Mendix Studio Pro 10.11 vers:all/* Mendix Studio Pro 10.12 vers:all/* Mendix Studio Pro 10.13 vers:all/* Mendix Studio Pro 10.14 vers:all/* Mendix Studio Pro 10.15 vers:all/* Mendix Studio Pro 10.16 vers:all/* Mendix Studio Pro 10.17 vers:all/* Mendix Studio Pro 10.18 vers:all/* Mendix Studio Pro 10.19 vers:all/* Mendix Studio Pro 10.20 vers:all/* Mendix Studio Pro 10.21 vers:all/* Mendix Studio Pro 10.22 vers:all/* Mendix Studio Pro 10.23 vers:all/* Mendix Studio Pro 10.24 vers:intdot/<10.24.21 Mendix Studio Pro 11.0 vers:all/* Mendix Studio Pro 11.1 vers:all/* Mendix Studio Pro 11.10 vers:all/* Mendix Studio Pro 11.11 vers:all/* Mendix Studio Pro 11.2 vers:all/* Mendix Studio Pro 11.3 vers:all/* Mendix Studio Pro 11.4 vers:all/* Mendix Studio Pro 11.5 vers:all/* Mendix Studio Pro 11.6 vers:intdot/<11.6.7 Mendix Studio Pro 11.7 vers:all/* Mendix Studio Pro 11.8 vers:all/* Mendix Studio Pro 11.9 vers:all/* CVSS Vendor Equipment Vulnerabilities v3 5.4 Siemens Siemens Mendix Studio Pro Improper Control of Generation of Code ('Code Injection') Background Critical Infrastructure Sectors: Critical Manufacturing, Energy Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities Expand All + CVE-2026-48192 Affected versions of Mendix Studio Pro do not properly validate or sanitize project files processed during the build pipeline. This could allow an attacker who tricks a user into opening and running a specially crafted malicious project locally on their system to execute arbitrary code in the context of that user. View CVE Details Affected Products Siemens Mendix Studio Pro Vendor: Siemens Product Version: Mendix Studio Pro 10.11, Mendix Studio Pro 10.12, Mendix Studio Pro 10.13, Mendix Studio Pro 10.14, Mendix Studio Pro 10.15, Mendix Studio Pro 10.16, Mendix Studio Pro 10.17, Mendix Studio Pro 10.18, Mendix Studio Pro 10.19, Mendix Studio Pro 10.20, Mendix Studio Pro 10.21, Mendix Studio Pro 10.22, Mendix Studio Pro 10.23, Mendix Studio Pro 10.24 < V10.24.21, Mendix Studio Pro 11.0, Mendix Studio Pro 11.1, Mendix Studio Pro 11.10, Mendix Studio Pro 11.11, Mendix Studio Pro 11.2, Mendix Studio Pro 11.3, Mendix Studio Pro 11.4, Mendix Studio Pro 11.5, Mendix Studio Pro 11.6 < V11.6.7, Mendix Studio Pro 11.7, Mendix Studio Pro 11.8, Mendix Studio Pro 11.9 Product Status: known_affected Remediations No fix planned Currently no fix is planned Vendor fix Update to V10.24.21 or later version https://docs.mendix.com/releasenotes/studio-pro/10.24/ Vendor fix Update to V11.6.7 or later version https://docs.mendix.com/releasenotes/studio-pro/11.6/ Relevant CWE: CWE-94 Improper Control of Generation of Code ('Code Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.4 MEDIUM CVSS:3.1/AV:N/AC:H/PR:H/UI:R/S:C/C:N/I:H/A:N Acknowledgments Siemens ProductCERT reported this vulnerability to CISA. General Recommendations As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity Additional Resources For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories Terms of Use The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use. Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Siemens ProductCERT SSA-779310 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-06-30 Date Revision Summary 2026-06-30 1 Publication Date 2026-07-07 2 Initial CISA Republication of Siemens ProductCERT SSA-779310 advisory Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Hitachi Energy e-mesh EMS

View CSAF Summary Hitachi Energy is aware of a buffer overflow vulnerability that affects e-mesh EMS product versions listed in this document. Successful exploitation of this vulnerability could lead to a buffer overflow condition, potentially resulting in application outages (denial of service) and possible arbitrary code execution. Please refer to the Recommended Immediate Actions for information about the…
Read full source summary
View CSAF Summary Hitachi Energy is aware of a buffer overflow vulnerability that affects e-mesh EMS product versions listed in this document. Successful exploitation of this vulnerability could lead to a buffer overflow condition, potentially resulting in application outages (denial of service) and possible arbitrary code execution. Please refer to the Recommended Immediate Actions for information about the mitigation/remediation. The following versions of Hitachi Energy e-mesh EMS are affected: Hitachi Energy e-mesh EMS 4.1.6, 4.4.2, 4.7.0 CVSS Vendor Equipment Vulnerabilities v3 8.1 Hitachi Energy Hitachi Energy e-mesh EMS Heap-based Buffer Overflow Background Critical Infrastructure Sectors: Energy Countries/Areas Deployed: Worldwide Company Headquarters Location: Switzerland Vulnerabilities Expand All + CVE-2026-42945 NGINX Plus and NGINX Open Source used in e-mesh EMS have a vulnerability in the ngx_http_rewrite_module module. This vulnerability exists when the rewrite directive is followed by a rewrite, if, or set directive and an unnamed Perl-Compatible Regular Expression (PCRE) capture (for example, $1, $2) with a replacement string that includes a question mark (?). An unauthenticated attacker along with conditions beyond its control can exploit this vulnerability by sending crafted HTTP requests. This may cause a heap buffer overflow in the NGINX worker process leading to a restart. Additionally, attackers can execute code on systems with Address Space Layout Randomization (ASLR) disabled or when the attacker can bypass ASLR. e-mesh EMS versions using NGINX v1.30.0 and below are affected. View CVE Details Affected Products Hitachi Energy e-mesh EMS Vendor: Hitachi Energy Product Version: e-mesh EMS versions 4.1.6, e-mesh EMS versions 4.4.2, e-mesh EMS versions 4.7.0 Product Status: known_affected Remediations Vendor fix Apply hotfix for respective e-mesh EMS versions to update NGINX to either v1.30.2 or latest Mitigation Ensure rewrite configuration does not contain "?" to replace unnamed captures, and ensure ASLR is set to active (value=2) across all deployment targets covering all 3 versions. Mitigation Underlying Ubuntu Server 20.04 LTS is End of Life. For e-mesh EMS versions 4.1.6/4.4.2 using Ubuntu 20.04 LTS, upgrade to Ubuntu Server 22.04, or 24.04, or activate Ubuntu Pro/ESM as an interim measure. Relevant CWE: CWE-122 Heap-based Buffer Overflow Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.1 HIGH CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H 4.0 9.2 CRITICAL CVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N Acknowledgments Hitachi Energy Internal Team Notice The information in this document is subject to change without notice and should not be construed as a commitment by Hitachi Energy. Hitachi Energy provides no warranty, express or implied, including warranties of merchantability and fitness for a particular purpose, for the information contained in this document, and assumes no responsibility for any errors that may appear in this document. In no event shall Hitachi Energy or any of its suppliers be liable for direct, indirect, special, incidental or consequential damages of any nature or kind arising from the use of this document, or from the use of any hardware or software described in this document, even if Hitachi Energy or its suppliers have been advised of the possibility of such damages. This document and parts hereof must not be reproduced or copied without written permission from Hitachi Energy and the contents hereof must not be imparted to a third party nor used for any unauthorized purpose. All rights to registrations and trademarks reside with their respective owners. Support For additional information and support please contact your product provider or Hitachi Energy service organization. For contact information, see https://www.hitachienergy.com/contact-us/ for Hitachi Energy contact-centers. General Mitigation Factors Recommended security practices and firewall configurations can help protect a process control network from attacks that originate from outside the network. Such practices include that process control systems are physically protected from direct access by unauthorized personnel, have no direct connections to the Internet, and are separated from other networks by means of a firewall system that has a minimal number of ports exposed, and others that have to be evaluated case by case. Process control systems should not be used for Internet surfing, instant messaging, or receiving e-mails. Portable computers and removable storage media should be carefully scanned for viruses before they are connected to a control system. Proper password policies and processes should be followed. Additional information on Industrial Control Systems Cybersecurity Best Practices can be found in the Hitachi Energy “Industrial Control Systems Cybersecurity Best Practices” Cybersecurity Notification. [1] SSVC SSVCv2/E:N/A:N/2026-06-29T17:00:59Z/ Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Hitachi Energy PSIRT 8DBD000253 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Hitachi Energy PSIRT directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-06-30 Date Revision Summary 2026-06-30 1 Initial public release 2026-07-07 2 Initial CISA Republication of Hitachi Energy PSIRT 8DBD000253 advisory Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Hitachi Energy PROMOD V

View CSAF Summary Hitachi Energy is aware of insecure HTTP transmission vulnerability in PROMOD V product versions listed in this document. This vulnerability could allow attackers to intercept or manipulate sensitive data in transit, potentially leading to credential theft, session hijacking, or unauthorized access. The following versions of Hitachi Energy PROMOD V are affected: PROMOD V vers:PROMOD_V/<=1.0.10 CVSS…
Read full source summary
View CSAF Summary Hitachi Energy is aware of insecure HTTP transmission vulnerability in PROMOD V product versions listed in this document. This vulnerability could allow attackers to intercept or manipulate sensitive data in transit, potentially leading to credential theft, session hijacking, or unauthorized access. The following versions of Hitachi Energy PROMOD V are affected: PROMOD V vers:PROMOD_V/<=1.0.10 CVSS Vendor Equipment Vulnerabilities v3 7.1 Hitachi Energy Hitachi Energy PROMOD V Reliance on HTTP instead of HTTPS Background Critical Infrastructure Sectors: Energy Countries/Areas Deployed: Worldwide Company Headquarters Location: Switzerland Vulnerabilities Expand All + CVE-2026-10763 PROMOD V is using insecure HTTP communication instead of HTTPS. The vulnerability is due to the lack of HTTPS support from 3rd party Digipede server. View CVE Details Affected Products Hitachi Energy PROMOD V Vendor: Hitachi Energy Product Version: PROMOD V versions 1.0.10 and prior Product Status: known_affected Remediations Vendor fix Upgrade to version 1.0.11 and enable HTTPS on Digipede server. [2] Refer to “1.0.11 PROMOD V User Guide”, Section 2 Essential Skills->Running PROMOD V->Digipede Grid. Alternatively, refer to the same section in the online help contained in the application. Mitigation Apply general mitigation factors Relevant CWE: CWE-1428 Reliance on HTTP instead of HTTPS Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.1 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:L/A:N 4.0 7 HIGH CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:H/VI:L/VA:N/SC:N/SI:N/SA:N Acknowledgments Hitachi Energy Internal Team Notice The information in this document is subject to change without notice and should not be construed as a commitment by Hitachi Energy. Hitachi Energy provides no warranty, express or implied, including warranties of merchantability and fitness for a particular purpose, for the information contained in this document, and assumes no responsibility for any errors that may appear in this document. In no event shall Hitachi Energy or any of its suppliers be liable for direct, indirect, special, incidental or consequential damages of any nature or kind arising from the use of this document, or from the use of any hardware or software described in this document, even if Hitachi Energy or its suppliers have been advised of the possibility of such damages. This document and parts hereof must not be reproduced or copied without written permission from Hitachi Energy and the contents hereof must not be imparted to a third party nor used for any unauthorized purpose. All rights to registrations and trademarks reside with their respective owners. Support For additional information and support please contact your product provider or Hitachi Energy service organization. For contact information, see https://www.hitachienergy.com/contact-us/ for Hitachi Energy contact-centers. General Mitigation Factors Recommended security practices and firewall configurations can help protect a process control network from attacks that originate from outside the network. Such practices include that process control systems are physically protected from direct access by unauthorized personnel, have no direct connections to the Internet, and are separated from other networks by means of a firewall system that has a minimal number of ports exposed, and others that have to be evaluated case by case. Process control systems should not be used for Internet surfing, instant messaging, or receiving e-mails. Portable computers and removable storage media should be carefully scanned for viruses before they are connected to a control system. Proper password policies and processes should be followed. Additional information on Industrial Control Systems Cybersecurity Best Practices can be found in the Hitachi Energy “Industrial Control Systems Cybersecurity Best Practices” Cybersecurity Notification. [1] SSVC SSVCv2/E:N/A:N/2026-06-29T12:01:59Z/ Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Hitachi Energy PSIRT 8DBD000250 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Hitachi Energy PSIRT directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-06-30 Date Revision Summary 2026-06-30 1 Initial public release 2026-07-07 2 Initial CISA Republication of Hitachi Energy PSIRT 8DBD000250 advisory Legal Notice and Terms of Use
Browse saved snapshots