Historical snapshot · Cybersecurity

CISA Advisories

Cybersecurity advisories and mitigation guidance for networks and critical infrastructure.

This page is an archived snapshot of the CISA Advisories feed collected on Jul 21, 2026, preserved by BioThreat Corporation. Publication dates belong to the original source; this snapshot is not a current advisory.
30 recordsOfficial source · JSON
· CISA Cybersecurity Advisory

Rockwell Automation Arena

View CSAF Summary Successful exploitation these vulnerabilities could allow an attacker to execute arbitrary code in the context of the current process. The following versions of Rockwell Automation Arena are affected: Arena <=V17.00.00 (CVE-2026-8085, CVE-2026-8312, CVE-2026-8313, CVE-2026-8314) CVSS Vendor Equipment Vulnerabilities v3 7.8 Rockwell Automation Rockwell Automation Arena Out-of-bounds Write Background…
Read full source summary
View CSAF Summary Successful exploitation these vulnerabilities could allow an attacker to execute arbitrary code in the context of the current process. The following versions of Rockwell Automation Arena are affected: Arena <=V17.00.00 (CVE-2026-8085, CVE-2026-8312, CVE-2026-8313, CVE-2026-8314) CVSS Vendor Equipment Vulnerabilities v3 7.8 Rockwell Automation Rockwell Automation Arena Out-of-bounds Write Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2026-8085 A security issue exists within Arena Simulation due to a memory corruption vulnerability in the model.exe (Siman) component. The vulnerability stems from improper validation of user-supplied data, which can result in an out-of-bounds write. An attacker could leverage this vulnerability to execute arbitrary code in the context of the current process by convincing a user to open a malicious file. View CVE Details Affected Products Rockwell Automation Arena Vendor: Rockwell Automation Product Version: Rockwell Automation Arena: <=V17.00.00 Product Status: known_affected Remediations Mitigation Rockwell Automation recommends users to update to V17.00.01 Relevant CWE: CWE-787 Out-of-bounds Write Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.8 HIGH CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H 4.0 7 HIGH CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N CVE-2026-8312 A security issue exists within Arena Simulation due to a memory corruption vulnerability in the expmt.exe (Siman) component. The vulnerability stems from improper validation of user-supplied data, which can result in an out-of-bounds write. An attacker could leverage this vulnerability to execute arbitrary code in the context of the current process by convincing a user to open a malicious file. View CVE Details Affected Products Rockwell Automation Arena Vendor: Rockwell Automation Product Version: Rockwell Automation Arena: <=V17.00.00 Product Status: known_affected Remediations Mitigation Rockwell Automation recommends users to update to V17.00.01 Relevant CWE: CWE-787 Out-of-bounds Write Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.8 HIGH CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H 4.0 7 HIGH CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N CVE-2026-8313 A security issue exists within Arena Simulation due to a memory corruption vulnerability in the linker.exe (Siman) component. The vulnerability stems from improper validation of user-supplied data, which can result in an out-of-bounds write. An attacker could leverage this vulnerability to execute arbitrary code in the context of the current process by convincing a user to open a malicious file. View CVE Details Affected Products Rockwell Automation Arena Vendor: Rockwell Automation Product Version: Rockwell Automation Arena: <=V17.00.00 Product Status: known_affected Remediations Mitigation Rockwell Automation recommends users to update to V17.00.01 Relevant CWE: CWE-787 Out-of-bounds Write Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.8 HIGH CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H 4.0 7 HIGH CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N CVE-2026-8314 A security issue exists within Arena Simulation due to a memory corruption vulnerability in the siman.exe (Siman) component. The vulnerability stems from improper validation of user-supplied data, which can result in an out-of-bounds write. An attacker could leverage this vulnerability to execute arbitrary code in the context of the current process by convincing a user to open a malicious file. View CVE Details Affected Products Rockwell Automation Arena Vendor: Rockwell Automation Product Version: Rockwell Automation Arena: <=V17.00.00 Product Status: known_affected Remediations Mitigation Rockwell Automation recommends users to update to V17.00.01 Relevant CWE: CWE-787 Out-of-bounds Write Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.8 HIGH CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H 4.0 7 HIGH CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N Acknowledgments Michael Heinzl reported these vulnerabilities to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. Revision History Initial Release Date: 2026-07-16 Date Revision Summary 2026-07-16 1 Initial Publication Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Establishing a Coordinated Vulnerability Disclosure Program to Work With Security Researchers

Developed by CISA, the National Security Agency (NSA) and international partners, this joint guidance contains best practices for software manufacturers and online service providers to design and implement a coordinated vulnerability disclosure (CVD) program for working with external security researchers that includes a clear vulnerability disclosure policy (VDP) and process for triaging, remediating and assigning…
Read full source summary
Developed by CISA, the National Security Agency (NSA) and international partners, this joint guidance contains best practices for software manufacturers and online service providers to design and implement a coordinated vulnerability disclosure (CVD) program for working with external security researchers that includes a clear vulnerability disclosure policy (VDP) and process for triaging, remediating and assigning Common Vulnerabilities and Exposures (CVE) identifiers to reported vulnerabilities. The guidance also provides considerations for leveraging third-party intermediaries, like CISA or other national computer security incident response teams, to substitute or supplement a CVD program. By implementing a robust CVD program aligned with this guidance, organizations can work transparently and collaboratively with security researchers to remediate vulnerabilities, build constructive relationships, enhance product security while improving vulnerability management processes, and demonstrate their dedication to protecting customers.
· CISA Cybersecurity Advisory

CISA Adds Two Known Exploited Vulnerabilities to Catalog

CISA has added two new vulnerabilities to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2023-4346 KNX Association KNX Protocol Connection Authorization Option 1 Overly Restrictive Account Lockout Mechanism Vulnerability CVE-2026-46817 Oracle E-Business Suite Improper Privilege Management Vulnerability These types of vulnerabilities are frequent attack vectors for…
Read full source summary
CISA has added two new vulnerabilities to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2023-4346 KNX Association KNX Protocol Connection Authorization Option 1 Overly Restrictive Account Lockout Mechanism Vulnerability CVE-2026-46817 Oracle E-Business Suite Improper Privilege Management Vulnerability These types of vulnerabilities are frequent attack vectors for malicious cyber actors and pose significant risks to the federal enterprise. Binding Operational Directive (BOD) 26-04: Prioritizing Security Updates Based on Risk establishes vulnerability management requirements for Federal Civilian Executive Branch (FCEB) agencies. BOD 26-04 reinforces the importance of the KEV Catalog and requires federal agencies to prioritize rapid remediation of high-risk vulnerabilities, specifically those identified by Common Vulnerabilities and Exposures (CVEs) listed in CISA’s KEV Catalog on publicly exposed assets that grant total control of the asset post-exploitation, while deferring action for lower-risk vulnerabilities. BOD 26-04 further establishes basic expectations for when agencies must check whether threat actors compromised the system before the patch was applied. While BOD 26-04 applies only to FCEB agencies, CISA encourages all organizations to adopt risk-based vulnerability management and prioritize remediation of KEV Catalog vulnerabilities. CISA will continue to add vulnerabilities to the catalog that meet the specified criteria. Aware of an exploited vulnerability not currently listed in the KEV Catalog? Submit it for potential addition through CISA’s KEV Nomination Form. Potential KEV additions must have a CVE ID, evidence of exploitation, and clear mitigation guidance.
· CISA Cybersecurity Advisory

Rockwell Automation 1715-AENTR EtherNet/IP Adapter

View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to read or delete files, stop tasks, modify memory, and change I/O states, potentially impacting the confidentiality, integrity, and availability of the device. The following versions of Rockwell Automation 1715-AENTR EtherNet/IP Adapter are affected: 1715-AENTR EtherNet/IP Adapter <=3.003 (CVE-2026-10577) CVSS Vendor Equipment…
Read full source summary
View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to read or delete files, stop tasks, modify memory, and change I/O states, potentially impacting the confidentiality, integrity, and availability of the device. The following versions of Rockwell Automation 1715-AENTR EtherNet/IP Adapter are affected: 1715-AENTR EtherNet/IP Adapter <=3.003 (CVE-2026-10577) CVSS Vendor Equipment Vulnerabilities v3 10 Rockwell Automation Rockwell Automation 1715-AENTR EtherNet/IP Adapter Missing Authentication for Critical Function Background Critical Infrastructure Sectors: Energy, Water and Wastewater, Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2026-10577 A security issue exists within the 1715-AENTR EtherNet/IP Adapter. The affected product exposes a network-accessible debug port that does not enforce proper privilege controls, allowing unauthenticated remote access to intrusive command-line interface (CLI) commands. If exploited, a threat actor could read or delete files, stop tasks, modify memory, and change I/O states, potentially impacting the confidentiality, integrity, and availability of the device. View CVE Details Affected Products Rockwell Automation 1715-AENTR EtherNet/IP Adapter Vendor: Rockwell Automation Product Version: Rockwell Automation 1715-AENTR EtherNet/IP Adapter: <=3.003 Product Status: known_affected Remediations Vendor fix Rockwell Automation recommends that users update to 1715-AENTR EtherNet/IP Adapter version 3.011 and later. Mitigation Rockwell Automation recommends users of the affected software who are not able to upgrade to one of the corrected versions should use their security best practices. https://support.rockwellautomation.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight Mitigation For more information, see the Rockwell Automation security advisory SD1785 https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1785.html Mitigation If you have any questions regarding this security issue and how to mitigate it,contact Rockwell Automation for help. https://www.rockwellautomation.com/en-us/company/about-us/contact-us.html Relevant CWE: CWE-306 Missing Authentication for Critical Function Metrics CVSS Version Base Score Base Severity Vector String 3.1 10 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H 4.0 10 CRITICAL CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H Acknowledgments Rockwell Automation reported this vulnerability to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as virtual private networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. Revision History Initial Release Date: 2026-07-14 Date Revision Summary 2026-07-14 1 Initial Republication of Rockwell Automation security advisory SD1785. Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

ABB Advant Master Online Builder

View CSAF Summary ABB became aware of vulnerability in the products versions listed as affected in the advisory, where an incorrect version of Online Builder (ONB) was included in the media. An update is available that resolves the vulnerability, see details in Recommended immediate actions. The following versions of ABB Advant Master Online Builder are affected: Control Builder A <=1.4/4 (CVE-2025-13162) 800xA for…
Read full source summary
View CSAF Summary ABB became aware of vulnerability in the products versions listed as affected in the advisory, where an incorrect version of Online Builder (ONB) was included in the media. An update is available that resolves the vulnerability, see details in Recommended immediate actions. The following versions of ABB Advant Master Online Builder are affected: Control Builder A <=1.4/4 (CVE-2025-13162) 800xA for Advant Master <=6.0.3-1, <=6.1.1-1, 6.1.1-3, 6.2.0-1 (CVE-2025-13162, CVE-2025-13162, CVE-2025-13162, CVE-2025-13162) CVSS Vendor Equipment Vulnerabilities v3 4.4 ABB ABB Advant Master Online Builder Uncontrolled Search Path Element Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Switzerland Vulnerabilities Expand All + CVE-2025-13162 The application improperly handles the search path for loading DLL´s, potentially allowing unauthorized libraries from untrusted directories. An attacker who obtains the necessary access could exploit the vulnerability leading to unauthorized code execution and compromising system integrity. View CVE Details Affected Products ABB Advant Master Online Builder Vendor: ABB Product Version: ABB Control Builder A <=1.4/4, ABB 800xA for Advant Master <=6.0.3-1, ABB 800xA for Advant Master <=6.1.1-1, ABB 800xA for Advant Master 6.1.1-3, ABB 800xA for Advant Master 6.2.0-1 Product Status: known_affected Remediations Vendor fix ABB has investigated the vulnerability and remediated it in the newly released versions. The vulnerability has been resolved in the product versions listed as fixed in the advisory. - Version 6.1.1-2 does not contain this vulnerability and therefore no update is required. The vulnerability was again introduced in 6.1.1-3 when an older ONB version was included in the release media. - Version 6.1.1-4 do not contain this vulnerability but present version 6.1.1-3 by 800xA System Installer and System Configuration Console (SCC). Version 6.1.1-4 is therefore withdrawn. - Version 6.2.0-2 do not contain this vulnerability but present version 6.2.0-1 by 800xA System Installer and System Configuration Console (SCC). Version 6.2.0-2 is therefore withdrawn. ABB recommends that customers apply the update at their earliest convenience. - Control Builder A: It is recommended to update Control Builder A to version 1.4/5 or later. - 800xA for Advant Master: - Versions 6.0.3-1 and earlier, - Versions 6.1.1-1 and earlier, - Versions 6.1.1-2, 6.1.1-3, and 6.1.1-4 should be updated to version 6.1.1-5 or later. - 800xA for Advant Master: - Versions 6.2.0-1 and 6.2.0-2 should be updated to version 6.2.0-3 or later. Mitigation Since it is required that the attacker has access to the system, it is important that all users that have access to the system are managed as recommended by ABB guidelines. - Allow only authorized users to log on to the system and enforce strong passwords that are changed regularly. - Restrict temporary connection of portable computers, USB memory devices and other removable data carriers. Computers that can be physically accessed by regular users should have ports for removable data carriers disabled or at least managed to only allow intended device types. For more information on recommended practices, see [1]. Workaround The recommendation is to upgrade to a version where the vulnerability is corrected. If an upgrade Is not possible and a workaround is needed, contact ABB Support. Relevant CWE: CWE-427 Uncontrolled Search Path Element Metrics CVSS Version Base Score Base Severity Vector String 3.1 4.4 MEDIUM CVSS:3.1/AV:L/AC:H/PR:L/UI:R/S:U/C:N/I:H/A:N Acknowledgments ABB PSIRT reported this vulnerability to CISA. Notice The information in this document is subject to change without notice, and should not be construed as a commitment by ABB. ABB provides no warranty, express or implied, including warranties of merchantability and fitness for a particular purpose, for the information contained in this document, and assumes no responsibility for any errors that may appear in this document. In no event shall ABB or any of its suppliers be liable for direct, indirect, special, incidental or consequential damages of any nature or kind arising from the use of this document, or from the use of any hardware or software described in this document, even if ABB or its suppliers have been advised of the possibility of such damages. This document and parts hereof must not be reproduced or copied without written permission from ABB, and the contents hereof must not be imparted to a third party nor used for any unauthorized purpose. All rights to registrations and trademarks reside with their respective owners. Frequently Asked Questions What is the scope of vulnerability? - An attacker who successfully exploited this vulnerability could insert and run arbitrary code in an affected system node. What causes the vulnerability? - The vulnerability is caused by not having restricted permission on an application directory where DLL files are stored. What is Advant Master Online Builder? - Online Builder is part of Control Builder A, being a set of applications for configuration and programming of Advant Master controllers. Online Builder is also part of 800xA for Advant Master, an extension package to System 800xA connecting to Advant Master controllers. What might an attacker use the vulnerability to do? - An attacker who successfully exploited this vulnerability can run arbitrary code in an affected node. How could an attacker exploit the vulnerability? - An attacker who obtains the necessary access could exploit vulnerability by placing malicious DLL´s in the unrestricted application directory, leading to unauthorized code execution and compromising system integrity. Could the vulnerability be exploited remotely? - No, to exploit this vulnerability an attacker would need to have physical access to an affected system node. Can functional safety be affected by an exploit of this vulnerability? - No. What does the update do? - The update of the Online Builder (ONB) resolves the vulnerability by adding restrictions to the application folder, requiring authentication. When this security advisory was issued, had this vulnerability been publicly disclosed? - No, ABB identified this vulnerability through its internal security assessment and verification processes. When this security advisory was issued, had ABB received any reports that this vulnerability was being exploited? - No, ABB had not received any information indicating that this vulnerability had been exploited when this security advisory was originally issued. Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of ABB PSIRT 7PAA020047 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact ABB PSIRT directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-06-23 Date Revision Summary 2026-06-23 1 Initial version. 2026-07-14 2 Initial CISA Republication of ABB PSIRT 7PAA020047 advisory Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

ABB T-MAC Plus

View CSAF Summary ABB became aware of vulnerability in the products versions listed as affected in the advisory. An update is available that resolves the reported vulnerabilities. An attacker who successfully exploited any of these vulnerabilities could potentially compromise the system in different ways. The following versions of ABB T-MAC Plus are affected: T-MAC Plus 4.0-24 (CVE-2025-14771, CVE-2025-14772,…
Read full source summary
View CSAF Summary ABB became aware of vulnerability in the products versions listed as affected in the advisory. An update is available that resolves the reported vulnerabilities. An attacker who successfully exploited any of these vulnerabilities could potentially compromise the system in different ways. The following versions of ABB T-MAC Plus are affected: T-MAC Plus 4.0-24 (CVE-2025-14771, CVE-2025-14772, CVE-2025-14773, CVE-2025-14774) CVSS Vendor Equipment Vulnerabilities v3 9.9 ABB ABB T-MAC Plus Files or Directories Accessible to External Parties, Authorization Bypass Through User-Controlled Key, Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting'), Incorrect Authorization Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Switzerland Vulnerabilities Expand All + CVE-2025-14771 File Disclosure in ABB T-MAC Plus web application allows authenticated users to exfiltrate files containing sensitive information via crafted HTTP GET request. View CVE Details Affected Products ABB T-MAC Plus Vendor: ABB Product Version: ABB T-MAC Plus 4.0-24 Product Status: known_affected Remediations Vendor fix ABB has investigated these vulnerabilities to provide adequate protection to customers. The problem is corrected in the following product versions: T-MAC Plus version 4.0-25 ABB recommends that customers apply the update at earliest convenience. Mitigation The misconfigurations on the IIS server, which were reported to security auditing, have been corrected. File Browsing Feature was enabled on that IIS server. That feature along with the default IIS site has been removed. Workaround Workarounds are specific measures that a user can take to help block an attack, for example, temporarily disabling the vulnerable feature may remove the exposure with well-known impact on functionality. ABB has tested the following workarounds. Although these workarounds will not correct the underlying vulnerability, they can help block known attack vectors. When a workaround reduces functionality, this is identified below as “Impact of workaround”. Relevant CWE: CWE-552 Files or Directories Accessible to External Parties Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.9 CRITICAL CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H CVE-2025-14772 Broken access controls in ABB T-MAC Plus web application allows unprivileged users to performs administrative operations View CVE Details Affected Products ABB T-MAC Plus Vendor: ABB Product Version: ABB T-MAC Plus 4.0-24 Product Status: known_affected Remediations Vendor fix ABB has investigated these vulnerabilities to provide adequate protection to customers. The problem is corrected in the following product versions: T-MAC Plus version 4.0-25 ABB recommends that customers apply the update at earliest convenience. Mitigation ABB T-MAC Plus web application supports several classes of users (e.g., Admin, Customer, Operator, etc.) with different roles. An authenticated user with low privileges (e.g., Customer) can execute administrative operations. The privileges associated to the different users have been revised and applied correctly. Workaround Workarounds are specific measures that a user can take to help block an attack, for example, temporarily disabling the vulnerable feature may remove the exposure with well-known impact on functionality. ABB has tested the following workarounds. Although these workarounds will not correct the underlying vulnerability, they can help block known attack vectors. When a workaround reduces functionality, this is identified below as “Impact of workaround”. Relevant CWE: CWE-639 Authorization Bypass Through User-Controlled Key Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.8 HIGH CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H CVE-2025-14773 Stored Cross-Site Scripting (XSS) in ABB T-MAC Plus web application allows authenticated users to execute arbitrary HTML or JavaScript code on victims browser. View CVE Details Affected Products ABB T-MAC Plus Vendor: ABB Product Version: ABB T-MAC Plus 4.0-24 Product Status: known_affected Remediations Vendor fix ABB has investigated these vulnerabilities to provide adequate protection to customers. The problem is corrected in the following product versions: T-MAC Plus version 4.0-25 ABB recommends that customers apply the update at earliest convenience. Mitigation A DOM-based XSS vulnerability is present. If a malicious actor gains access to the operations network and can create or edit an existing entity, they could insert malicious JavaScript code to be executed in the web forms. New T-MAC Plus version 4.0-25 will correct the vulnerability. Workaround Workarounds are specific measures that a user can take to help block an attack, for example, temporarily disabling the vulnerable feature may remove the exposure with well-known impact on functionality. ABB has tested the following workarounds. Although these workarounds will not correct the underlying vulnerability, they can help block known attack vectors. When a workaround reduces functionality, this is identified below as “Impact of workaround”. Relevant CWE: CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') Metrics CVSS Version Base Score Base Severity Vector String 3.1 8 HIGH CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H CVE-2025-14774 Insecure network protocol in ABB T-MAC Plus allows unauthenticated attackers to perform a denial-of-service (DoS) of the Card Reader service. View CVE Details Affected Products ABB T-MAC Plus Vendor: ABB Product Version: ABB T-MAC Plus 4.0-24 Product Status: known_affected Remediations Vendor fix ABB has investigated these vulnerabilities to provide adequate protection to customers. The problem is corrected in the following product versions: T-MAC Plus version 4.0-25 ABB recommends that customers apply the update at earliest convenience. Mitigation If a malicious actor gains physical access to a serial device, disables it, connects a malicious device with same IP address, and sends a specially crafted message, the service responsible for communicating with the device will be blocked until a manual restart is performed. New T-MAC Plus version 4.0-25 will correct the vulnerability. Workaround Workarounds are specific measures that a user can take to help block an attack, for example, temporarily disabling the vulnerable feature may remove the exposure with well-known impact on functionality. ABB has tested the following workarounds. Although these workarounds will not correct the underlying vulnerability, they can help block known attack vectors. When a workaround reduces functionality, this is identified below as “Impact of workaround”. Relevant CWE: CWE-863 Incorrect Authorization Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.4 HIGH CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H Acknowledgments Angelo Catalani of the Italian National Cybersecurity Agency (ACN) responsibly disclosed the vulnerabilities and provided valuable input on product improvements. Notice The information in this document is subject to change without notice, and should not be construed as a commitment by ABB. ABB provides no warranty, express or implied, including warranties of merchantability and fitness for a particular purpose, for the information contained in this document, and assumes no responsibility for any errors that may appear in this document. In no event shall ABB or any of its suppliers be liable for direct, indirect, special, incidental or consequential damages of any nature or kind arising from the use of this document, or from the use of any hardware or software described in this document, even if ABB or its suppliers have been advised of the possibility of such damages. This document and parts hereof must not be reproduced or copied without written permission from ABB, and the contents hereof must not be imparted to a third party nor used for any unauthorized purpose. All rights to registrations and trademarks reside with their respective owners. Frequently Asked Questions What causes the vulnerability? - The vulnerabilities are caused by: - Wrong configuration in T-MAC Plus IIS Server. - Wrong configuration of privileges of users. - Lack of encryption in communication protocol. What is T-MAC Plus? - T-MAC Plus is a Terminal Management System (TMS) that handles the different operations (receipt and dispatch product, access control, product movement in the tank farm, …) in a terminal. It is applicable to different type of products such as chemical and petroleum terminals, pipeline or refinery tankage, bulk plants or hydrogen terminals. The following components are affected: - TMAC Plus Web application - Communication protocol with Card Readers What might an attacker use the vulnerability to do? - An attacker who successfully exploited this vulnerability could cause the affected system node to stop or become inaccessible and allow the attacker to insert and run arbitrary code. How could an attacker exploit the vulnerability? - An attacker could try to exploit the vulnerability by creating a specially crafted message and sending the message to an affected system node. This would require that the attacker has access to the system network, by connecting to the network directly. Recommended practices help mitigate such attacks, see section Mitigating Factors. Could the vulnerability be exploited remotely? - No, to exploit this vulnerability an attacker would need to have physical access to an affected system node. Can functional safety be affected by an exploit of this vulnerability? - While these vulnerabilities primarily impact confidentiality, integrity, and availability, they do not directly affect functional safety in the traditional sense What does the update do? - The update removes the vulnerability by modifying the way that the T-MAC Plus web application and the communication protocol are configured. When this security advisory was issued, had this vulnerability been publicly disclosed? - No, ABB received information about this vulnerability through responsible disclosure. When this security advisory was issued, had ABB received any reports that this vulnerability was being exploited? - No, ABB had not received any information indicating that this vulnerability had been exploited when this security advisory was originally. Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of ABB PSIRT 9AKK108472A7840 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact ABB PSIRT directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-06-03 Date Revision Summary 2026-06-03 1 Initial version. 2026-07-14 2 Initial CISA Republication of ABB PSIRT 9AKK108472A7840 advisory Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

ABB Ability Edgenius

View CSAF Summary ABB is aware of public reports of a vulnerability CVE‑2026‑31431 (Copy Fail) in the product versions listed as affected in the advisory. An update is available that resolves a publicly reported vulnerability. CVE‑2026‑31431 (Copy Fail) is a Linux kernel vulnerability that may allow a locally authenticated user or compromised container workload to gain elevated (root) privileges on affected systems.…
Read full source summary
View CSAF Summary ABB is aware of public reports of a vulnerability CVE‑2026‑31431 (Copy Fail) in the product versions listed as affected in the advisory. An update is available that resolves a publicly reported vulnerability. CVE‑2026‑31431 (Copy Fail) is a Linux kernel vulnerability that may allow a locally authenticated user or compromised container workload to gain elevated (root) privileges on affected systems. Once root access is obtained, the attacker can effectively gain complete control of the system The following versions of ABB Ability Edgenius are affected: Ability Edgenius >=3.2.0.0|<3.2.4.1 installed on ABB Ability Edgenius Gateway - bE100, >=3.2.0.0|<3.2.4.1 installed on ABB Ability Edgenius Gateway - E3100C, >=3.2.0.0|<3.2.4.1 installed on ABB Ability Edgenius Server - vE1000 (CVE-2026-31431, CVE-2026-31431, CVE-2026-31431) CVSS Vendor Equipment Vulnerabilities v3 7.8 ABB ABB Ability Edgenius Incorrect Resource Transfer Between Spheres Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Switzerland Vulnerabilities Expand All + CVE-2026-31431 CVE‑2026‑31431 (Copy Fail) is a Linux kernel vulnerability that may allow a locally authenticated user or compromised container workload to gain elevated (root) privileges on affected systems. The issue originates in the Linux kernel’s cryptographic subsystem and impacts kernels used by most major Linux distributions released since 2017. Successful exploitation requires local code execution, however, in shared, containerized, or multi‑tenant environments this may increase the security risk View CVE Details Affected Products ABB Ability Edgenius Vendor: ABB Product Version: ABB Ability Edgenius >=3.2.0.0|<3.2.4.1 installed on ABB Ability Edgenius Gateway - bE100, ABB Ability Edgenius >=3.2.0.0|<3.2.4.1 installed on ABB Ability Edgenius Gateway - E3100C, ABB Ability Edgenius >=3.2.0.0|<3.2.4.1 installed on ABB Ability Edgenius Server - vE1000 Product Status: known_affected Remediations Vendor fix The problem is corrected in the following product versions: - Edgenius 3.2.4.1 ABB recommends that customers apply the update at earliest convenience. Mitigation Mitigating factors describe conditions and circumstances that make an attack that exploits the vulnerability difficult or less likely to succeed. Refer to section General security recommendations for further advise on how to keep your system secure. Recommended mitigation factors - Limit access to ssh or cockpit - By default, no additional lower privilege users are present on Edgenius installations Relevant CWE: CWE-669 Incorrect Resource Transfer Between Spheres Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.8 HIGH CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H Acknowledgments ABB PSIRT reported this vulnerability to CISA. Notice The information in this document is subject to change without notice, and should not be construed as a commitment by ABB. ABB provides no warranty, express or implied, including warranties of merchantability and fitness for a particular purpose, for the information contained in this document, and assumes no responsibility for any errors that may appear in this document. In no event shall ABB or any of its suppliers be liable for direct, indirect, special, incidental or consequential damages of any nature or kind arising from the use of this document, or from the use of any hardware or software described in this document, even if ABB or its suppliers have been advised of the possibility of such damages. This document and parts hereof must not be reproduced or copied without written permission from ABB, and the contents hereof must not be imparted to a third party nor used for any unauthorized purpose. All rights to registrations and trademarks reside with their respective owners. Frequently Asked Questions What causes the vulnerability? - A flaw was found in the Linux kernel's algif_aead cryptographic algorithm interface. An incorrect 'in-place operation' was introduced, where the source and destination data mappings were different. This could lead to unexpected behavior or data integrity issues during cryptographic operations, potentially impacting the reliability of encrypted communications. What is Edgenius? - ABB Ability™ Edgenius is an edge computing platform that - Connects to control systems, devices, and equipment - Collects and contextualizes operational data - Hosts applications that deliver real-time insights and AI-driven recommendations What might an attacker use the vulnerability to do? - Successful exploitation could enable a local user attacker to gain administrative control of the system node, execute arbitrary code, or cause the node to become unavailable. How could an attacker exploit the vulnerability? - An attacker could exploit this vulnerability after obtaining local access to the system. By invoking the Linux kernel’s affected cryptographic interface (algif_aead), the attacker can trigger incorrect memory handling in the kernel. This allows the attacker to escalate privileges from a normal user to full administrative (root) access on the affected system node Could the vulnerability be exploited remotely? - No, to exploit this vulnerability an attacker would need to have local access (physical access or through valid SSH credentials) to an affected system node. What does the update do? - The update resolves the issue by incorporating the security update of the Linux kernel. When this security advisory was issued, had this vulnerability been publicly disclosed? - Yes, this vulnerability has been publicly disclosed. When this security advisory was issued, had ABB received any reports that this vulnerability was being exploited? - No, ABB had not received any information indicating that this vulnerability had been exploited for Edgenius when this security advisory was originally issued. Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of ABB PSIRT 7PAA024620 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact ABB PSIRT directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-06-25 Date Revision Summary 2026-06-25 1 Initial version. 2026-07-14 2 Initial CISA Republication of ABB PSIRT 7PAA024620 advisory Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

CISA Urges SharePoint Hardening After New Exploitations

Update July 16, 2026: CISA has updated this Alert to reflect the addition of CVE-2026-58644 to its Known Exploited Vulnerabilities (KEV) Catalog on July 16, 2026. CISA is aware of active exploitation of vulnerabilities CVE-2026-32201, CVE-2026-45659, CVE-2026-56164, and CVE-2026-58644, enabling cyber threat actors to gain unauthorized access to on-premises SharePoint Server instances. These vulnerabilities affect…
Read full source summary
Update July 16, 2026: CISA has updated this Alert to reflect the addition of CVE-2026-58644 to its Known Exploited Vulnerabilities (KEV) Catalog on July 16, 2026. CISA is aware of active exploitation of vulnerabilities CVE-2026-32201, CVE-2026-45659, CVE-2026-56164, and CVE-2026-58644, enabling cyber threat actors to gain unauthorized access to on-premises SharePoint Server instances. These vulnerabilities affect all supported on-premises SharePoint Server versions (Subscription Edition, 2019, and 2016) and involve establishing remote code execution (RCE) and post-exploitation activities, such as stealing Internet Information Services (IIS) machine keys and performing deserialization techniques, to gain persistence and deploy malware. Organizations should monitor affected SharePoint Servers closely for any signs of exploitation or unusual activity. Additionally, the following newly disclosed CVE is not yet known to have been exploited, but Microsoft has identified it as posing a potential risk if left unpatched: CVE-2026-55040 CISA urges organizations to detect and remediate a potential compromise by implementing the following recommendations: Apply the latest patches and security updates from Microsoft, verify that installation completes successfully, and shorten patching cycles when possible. Verify that Antimalware Scan Interface (AMSI) integration is enabled for each SharePoint web application. Follow Microsoft’s Configure AMSI integration with SharePoint Server guidance to ensure proper configuration and select the “Full Mode” option for the Request Body Scan Mode, where feasible. When compromise is expected, use the following AMSI and Microsoft Defender Antivirus (MDAV) detections, and implement your organization’s incident response plan for any positive detections: AMSI: Exploit:Script/SuspSignoutReqBody.A – request body scanning; SharePoint Server Subscription only; Microsoft has blocked observed attempts. AMSI: Exploit:Script/ToolPaneAuthBypass.A – request header scanning; SharePoint Server 2016, 2019, and Subscription Edition. AMSI: Exploit:Script/ToolPaneAuthBypass.C – RCE coverage; SharePoint Server 2016, 2019, and Subscription Edition. MDAV: Backdoor:MSIL/LeakFang.A!dha – post-exploitation activity alert involving IIS-protected secrets. In addition, CISA recommends that organizations implement the following SharePoint Server hardening measures: Before rotating IIS machine keys, hunt for and remediate any intrusion artifacts, including machine-key harvesters, that could allow for the keys to be stolen again. Review Microsoft’s Improved ASP.NET view state security and key management for best practices. Establish tailored logging mechanisms to detect and monitor exploitation activities. Review telemetry for anomalous requests, suspicious SharePoint worker-process activity, webshells, and machine-key access. For more information, see CISA’s Best Practices for Event Logging and Threat Detection. Avoid exposing SharePoint Servers directly to the internet unless necessary; and if necessary, only configure a SharePoint Server behind a Layer 7 reverse proxy or equivalent application-layer security control that requires authentication and can inspect and filter requests. Block external access to SharePoint Central Administration, restrict farm and database communications to required systems, and review Microsoft’s SharePoint Server security-hardening guidance for role-specific ports, services, and Web.config settings. CISA urges users and administrators to review the Alert UPDATE: Microsoft Releases Guidance on Exploitation of SharePoint Vulnerabilities and apply necessary updates. CISA added the following vulnerabilities to its Known Exploited Vulnerabilities (KEV) Catalog: CVE-2026-32201 on April 14, 2026; CVE-2026-45659 on July 1, 2026; CVE-2026-56164 on July 14, 2026; and CVE-2026-58644 on July 16, 2026. Note: CISA may update this Alert to reflect new guidance issued by CISA or other parties. Organizations should report incidents or anomalous activity to CISA via CISA’s 24/7 Operations Center at contact@cisa.dhs.gov or 1-844-Say-CISA (1-844-729-2472). Disclaimer The information in this report is being provided “as is” for informational purposes only. CISA does not endorse any commercial entity, product, company, or service, including any entities, products, or services linked within this document. Any reference to specific commercial entities, products, processes, or services by service mark, trademark, manufacturer, or otherwise, does not constitute or imply endorsement, recommendation, or favoring by CISA. Acknowledgements Microsoft contributed to this Alert.
· CISA Cybersecurity Advisory

CISA Adds Four Known Exploited Vulnerabilities to Catalog

CISA has added four new vulnerabilities to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-15409 SonicWall SMA1000 Appliances Server-Side Request Forgery Vulnerability CVE-2026-15410 SonicWall SMA1000 Appliances Code Injection Vulnerability CVE-2026-56155 Microsoft Active Directory Federation Services Insufficient Granularity of Access Control Vulnerability…
Read full source summary
CISA has added four new vulnerabilities to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-15409 SonicWall SMA1000 Appliances Server-Side Request Forgery Vulnerability CVE-2026-15410 SonicWall SMA1000 Appliances Code Injection Vulnerability CVE-2026-56155 Microsoft Active Directory Federation Services Insufficient Granularity of Access Control Vulnerability CVE-2026-56164 Microsoft SharePoint Server Missing Authentication for Critical Function Vulnerability These types of vulnerabilities are a frequent attack vector for malicious cyber actors and pose significant risks to the federal enterprise. Binding Operational Directive (BOD) 26-04: Prioritizing Security Updates Based on Risk establishes vulnerability management requirements for Federal Civilian Executive Branch (FCEB) agencies. BOD 26-04 reinforces the importance of the KEV Catalog and requires federal agencies to prioritize rapid remediation of high-risk vulnerabilities, specifically those identified by Common Vulnerabilities and Exposures (CVEs) listed in CISA’s KEV Catalog on publicly exposed assets that grant total control of the asset post-exploitation, while deferring action for lower-risk vulnerabilities. BOD 26-04 further establishes basic expectations for when agencies must check whether threat actors compromised the system before the patch was applied. While BOD 26-04 applies only to FCEB agencies, CISA encourages all organizations to adopt risk-based vulnerability management and prioritize remediation of KEV Catalog vulnerabilities. CISA will continue to add vulnerabilities to the catalog that meet the specified criteria. Aware of an exploited vulnerability not currently listed in the KEV Catalog? Submit it for potential addition through CISA’s KEV Nomination Form. Potential KEV additions must have a CVE ID, evidence of exploitation, and clear mitigation guidance.
· CISA Cybersecurity Advisory

CISA Adds One Known Exploited Vulnerability to Catalog

CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2008-4128 Cisco IOS Cross-Site Request Forgery Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 26-04: Prioritizing Security Updates Based on…
Read full source summary
CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2008-4128 Cisco IOS Cross-Site Request Forgery Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 26-04: Prioritizing Security Updates Based on Risk establishes vulnerability management requirements for Federal Civilian Executive Branch (FCEB) agencies. BOD 26-04 reinforces the importance of the KEV Catalog and requires federal agencies to prioritize rapid remediation of high-risk vulnerabilities, specifically those identified by Common Vulnerabilities and Exposures (CVEs) listed in CISA’s KEV Catalog on publicly exposed assets that grant total control of the asset post-exploitation, while deferring action for lower-risk vulnerabilities. BOD 26-04 further establishes basic expectations for when agencies must check whether threat actors compromised the system before the patch was applied. While BOD 26-04 applies only to FCEB agencies, CISA encourages all organizations to adopt risk-based vulnerability management and prioritize remediation of KEV Catalog vulnerabilities. CISA will continue to add vulnerabilities to the catalog that meet the specified criteria. Aware of an exploited vulnerability not currently listed in the KEV Catalog? Submit it for potential addition through CISA’s KEV Nomination Form. Potential KEV additions must have a CVE ID, evidence of exploitation, and clear mitigation guidance.
Browse saved snapshots