View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to cause a denial-of-service condition. The following versions of NASA Core Flight System (cFS) Health & Safety (HS) Application are affected: Core Flight System (cFS) Health & Safety (HS) Application CVSS Vendor Equipment Vulnerabilities v3 7.5 NASA NASA Core Flight System (cFS) Health & Safety (HS) Application NULL Pointer…
Read more of the source summary
Dereference Background Critical Infrastructure Sectors: Transportation Systems Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2026-15352 A vulnerability exists in the Health & Safety (HS) application of NASA's Core Flight System (cFS). The flaw allows the application to crash via segmentation fault when processing a routine Housekeeping Telemetry request, leading to denial of service. View CVE Details Affected Products NASA Core Flight System (cFS) Health & Safety (HS) Application Vendor: NASA Product Version: NASA Core Flight System (cFS) Health & Safety (HS) Application: <v7.0.1 Product Status: known_affected Remediations Mitigation NASA recommends users update to v7.0.1…
View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker with local or physical access to cause memory corruption, unintended information disclosure, application instability, or a denial-of-service condition in the affected product. The following versions of AutomationDirect Productivity Suite are affected: Productivity Suite <=v4.6.2.2 (CVE-2026-60063, CVE-2026-61389,…
Read more of the source summary
CVE-2026-60140, CVE-2026-57896, CVE-2026-60073, CVE-2026-61378) CVSS Vendor Equipment Vulnerabilities v3 7 AutomationDirect AutomationDirect Productivity Suite Out-of-bounds Write, Out-of-bounds Read, Divide By Zero Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2026-60063 An out-of-bounds write vulnerability in the Productivity Suite allows a local attacker to trigger kernel memory corruption via a crafted IOCTL request, potentially resulting in privilege escalation or system instability. View CVE Details Affected Products AutomationDirect Productivity Suite Vendor: AutomationDirect Product Version: AutomationDirect Productivity Suite: <=v4.6.2.2…
View CSAF Summary Successful exploitation these vulnerabilities could allow an attacker to execute arbitrary code in the context of the current process. The following versions of Rockwell Automation Arena are affected: Arena <=V17.00.00 (CVE-2026-8085, CVE-2026-8312, CVE-2026-8313, CVE-2026-8314) CVSS Vendor Equipment Vulnerabilities v3 7.8 Rockwell Automation Rockwell Automation Arena Out-of-bounds Write Background…
Read more of the source summary
Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2026-8085 A security issue exists within Arena Simulation due to a memory corruption vulnerability in the model.exe (Siman) component. The vulnerability stems from improper validation of user-supplied data, which can result in an out-of-bounds write. An attacker could leverage this vulnerability to execute arbitrary code in the context of the current process by convincing a user to open a malicious file. View CVE Details Affected Products Rockwell Automation Arena Vendor: Rockwell Automation Product Version: Rockwell Automation Arena: <=V17.00.00 Product Status: known_affected Remediations Mitigation…
CISA has added three new vulnerabilities to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-25089 Fortinet FortiSandbox OS Command Injection Vulnerability CVE-2026-39808 Fortinet FortiSandbox OS Command Injection Vulnerability CVE-2026-58644 Microsoft SharePoint Deserialization of Untrusted Data Vulnerability These types of vulnerabilities are frequent attack…
Read more of the source summary
vectors for malicious cyber actors and pose significant risks to the federal enterprise. Binding Operational Directive (BOD) 26-04: Prioritizing Security Updates Based on Risk establishes vulnerability management requirements for Federal Civilian Executive Branch (FCEB) agencies. BOD 26-04 reinforces the importance of the KEV Catalog and requires federal agencies to prioritize rapid remediation of high-risk vulnerabilities, specifically those identified by Common Vulnerabilities and Exposures (CVEs) listed in CISA’s KEV Catalog on publicly exposed assets that grant total control of the asset post-exploitation, while deferring action for lower-risk vulnerabilities. BOD 26-04 further establishes basic expectations for when agencies must check whether threat actors…
View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to cause a denial-of-service condition. The following versions of Rockwell Automation CompactLogix, ControlLogix, Compact GuardLogix and GuardLogix are affected: CompactLogix 5370 <=V35.015 (CVE-2025-12011, CVE-2025-12012, CVE-2025-11698) Compact GuardLogix 5370 <=V35.015 (CVE-2025-12011, CVE-2025-12012, CVE-2025-11698)…
View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to cause a denial-of-service condition. The following versions of Rockwell Automation 1756-EN2, 1756-EN3, and 1756-ENBT are affected: 1756-EN3 <=V12.001 (CVE-2026-9653) 1756-EN2 <=V12.001 (CVE-2026-9653) 1756-ENBT V6.006 (CVE-2026-9653) CVSS Vendor Equipment Vulnerabilities v3 7.5 Rockwell Automation Rockwell Automation 1756-EN2,…
Read more of the source summary
1756-EN3, and 1756-ENBT Improper Validation of Integrity Check Value Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2026-9653 A denial-of-service security issue exists across all the 1756-EN2, EN3, and ENBT communication module due to improper validation of CIP Implicit Connection packets. An attacker on the network can exploit this by sending crafted packets to continuously disrupt device connections, though device connections will recover immediately after. View CVE Details Affected Products Rockwell Automation 1756-EN2, 1756-EN3, and 1756-ENBT Vendor: Rockwell Automation Product Version: Rockwell Automation 1756-EN3: <=V12.001,…
View CSAF Summary Successful exploitation of this vulnerability could allow an authenticated attacker to inject malicious scripts on the server. The following versions of Rockwell Automation FactoryTalk DataMosaix are affected: DataMosaix Private Cloud <=8.02 (CVE-2026-9292) CVSS Vendor Equipment Vulnerabilities v3 6.1 Rockwell Automation Rockwell Automation FactoryTalk DataMosaix Improper Neutralization of Input…
Read more of the source summary
During Web Page Generation ('Cross-site Scripting') Background Critical Infrastructure Sectors: Critical Manufacturing, Information Technology Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2026-9292 A Stored Cross-Site Scripting security issue exists within FactoryTalk DataMosaix Private Cloud. The vulnerability stems from improper neutralization of user-supplied input within the Workflows configuration. An authenticated attacker with high privileges can inject malicious scripts that are permanently stored on the server. This vulnerability can result in the execution of malicious JavaScript when other users access the affected page, potentially allowing for account takeover, credential theft, or…
View CSAF Summary Successful exploitation of this vulnerability allows an authenticated attacker to escalate privileges and access spaces outside their assigned partition, within the same Salto ProAccess Space installation or system. Exploitation requires valid authenticated operator credentials and the partition feature to be enabled; installations without partitioning are not affected. The following versions of…
Read more of the source summary
SALTO ProAccess Space are affected: ProAccess Space <6.13 (CVE-2026-11889) CVSS Vendor Equipment Vulnerabilities v3 6.5 SALTO SALTO ProAccess Space Authorization Bypass Through User-Controlled Key Background Critical Infrastructure Sectors: Commercial Facilities, Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Spain Vulnerabilities Expand All + CVE-2026-11889 SALTO ProAccess Space software using the tenancy feature / logical partition is vulnerable to a privilege escalation attack that could allow an authorized attacker to access any space managed by the affected product. View CVE Details Affected Products SALTO ProAccess Space Vendor: SALTO Product Version: SALTO ProAccess Space: <6.13 Product Status: known_affected Remediations…
View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to cause a denial-of-service condition on the affected product. The following versions of Rockwell Automation Flex 5000 Adapter are affected: Flex 5000 Adapter 6.011 (CVE-2026-12659) CVSS Vendor Equipment Vulnerabilities v3 7.5 Rockwell Automation Rockwell Automation Flex 5000 Adapter Double Free Background Critical…
Read more of the source summary
Infrastructure Sectors: Critical Manufacturing, Information Technology Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2026-12659 A denial-of-service security issue exists in the affected products. The security issue stems from improper handling of exceptional conditions when processing crafted CIP packets sent to the adapter. A power cycle is required to recover the module and associated I/O. View CVE Details Affected Products Rockwell Automation Flex 5000 Adapter Vendor: Rockwell Automation Product Version: Rockwell Automation Flex 5000 Adapter: 6.011 Product Status: known_affected Remediations Vendor fix Rockwell Automation recommends users to upgrade to the following: Flex 5000 Adapter version 6.012. Mitigation…
View CSAF Summary Multiple SICAM 8 products are affected by multiple vulnerabilities that could lead to denial of service, namely: - SICAM A8000 Device firmware - CPCI85 for CP-8031/CP-8050 - SICORE for CP-8010/CP-8012 - SICAM EGS Device firmware - CPCI85 - SICAM S8000 - SICORE Siemens has released new versions for the affected products and recommends to update to the latest versions. The following versions of…
Read more of the source summary
Siemens SICAM 8 are affected: CPCI85 Central Processing/Communication vers:intdot/<26.20 (CVE-2026-54798, CVE-2026-54799, CVE-2026-54800, CVE-2026-54801) SICORE Base system vers:intdot/<26.20.0 (CVE-2026-54798, CVE-2026-54799, CVE-2026-54800, CVE-2026-54801) CVSS Vendor Equipment Vulnerabilities v3 7.2 Siemens Siemens SICAM 8 Active Debug Code, Initialization of a Resource with an Insecure Default, Unverified Password Change Background Critical Infrastructure Sectors: Critical Manufacturing, Energy Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities Expand All + CVE-2026-54798 The affected application includes a debugging interface that is accessible through HTTP endpoints. This could allow an authenticated attacker to disrupt the…
BioThreat brings together reports from the listed public sources. Open the linked title to read the publisher’s original report and any later corrections. Third-party reports retain their own rights and licenses.
A source date is the date the publisher issued or updated a report. A snapshot date is the day BioThreat collected a copy of the feed. The same report can appear in multiple snapshots, and some days have no saved copy.
Open a feed or saved snapshot for original links and machine-readable JSON, where available. Use MERIDIAN to compare reporting across sources and dates.