Historical snapshot · Cybersecurity

CISA Advisories

Cybersecurity advisories and mitigation guidance for networks and critical infrastructure.

This page is an archived snapshot of the CISA Advisories feed collected on Aug 13, 2026, preserved by BioThreat Corporation. Publication dates belong to the original source; this snapshot is not a current advisory.
30 recordsOfficial source · JSON
· CISA Cybersecurity Advisory

Watchfire Controller Software

View CSAF Summary Successful exploitation of this vulnerability could allow a malicious user the ability to deliver malicious firmware that can update and gain full control of the controller. The following versions of Watchfire Controller Software are affected: BC550 12.30 (CVE-2026-5846) BC750 11.33 (CVE-2026-5846) BC750 12.35 (CVE-2026-5846) BC760 12.38 (CVE-2026-5846) BC760 13.00 (CVE-2026-5846) BC760DC 12.39…
Read full source summary
View CSAF Summary Successful exploitation of this vulnerability could allow a malicious user the ability to deliver malicious firmware that can update and gain full control of the controller. The following versions of Watchfire Controller Software are affected: BC550 12.30 (CVE-2026-5846) BC750 11.33 (CVE-2026-5846) BC750 12.35 (CVE-2026-5846) BC760 12.38 (CVE-2026-5846) BC760 13.00 (CVE-2026-5846) BC760DC 12.39 (CVE-2026-5846) CVSS Vendor Equipment Vulnerabilities v3 5.7 Watchfire Watchfire Controller Software Use of Hard-coded Cryptographic Key Background Critical Infrastructure Sectors: Commercial Facilities, Critical Manufacturing, Healthcare and Public Health, Financial Services Countries/Areas Deployed: United States, Dominican Republic, Canada, Peru, El Salvador Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2026-5846 The affected product contains self-signed hard-coded RSA private keys and corresponding X.509 certificates used for authenticating and encrypting HTTPS/TLS connections to the controller's built-in web management interface. These keys are embedded in plaintext within the application patch binaries in the firmware directly from Watchfire's Remote Support filestore. View CVE Details Affected Products Watchfire Controller Software Vendor: Watchfire Product Version: Watchfire BC550: 12.30, Watchfire BC750: 11.33, Watchfire BC750: 12.35, Watchfire BC760: 12.38, Watchfire BC760: 13.00, Watchfire BC760DC: 12.39 Product Status: known_affected Remediations Mitigation Watchfire has applied the required security patch to all affected controllers under its management. Watchfire recommends users verify their controller software version and upgrade to one of the approved versions below, if they are not already on an approved patch level. Vendor fix Watchfire has issued patches to disable the use of the existing certificates. Users using BC550; 12.30 should upgrade to 12.31 SP1 Vendor fix Watchfire has issued patches to disable the use of the existing certificates. Users using BC750; 11.33 should upgrade to 11.34 Vendor fix Watchfire has issued patches to disable the use of the existing certificates. Users using BC750; 12.35 should upgrade to 12.36 SP1 Vendor fix Watchfire has issued patches to disable the use of the existing certificates. Users using BC760; 12.38 should upgrade to 12.41 SP1 Vendor fix Watchfire has issued patches to disable the use of the existing certificates. Users using BC760; 13.00 should upgrade to 14.00 SP1 Vendor fix Watchfire has issued patches to disable the use of the existing certificates. Users using BC760DC; 12.39 should upgrade to 12.41 SP1 Relevant CWE: CWE-321 Use of Hard-coded Cryptographic Key Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.7 MEDIUM CVSS:3.1/AV:N/AC:H/PR:H/UI:R/S:U/C:H/I:H/A:N 4.0 7.6 HIGH CVSS:4.0/AV:N/AC:H/AT:P/PR:N/UI:P/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N Acknowledgments Reporter Name(s): James Tillson reported this vulnerability to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. This vulnerability has a high attack complexity. Revision History Initial Release Date: 2026-07-30 Date Revision Summary 2026-07-30 1 Initial Publication 2026-07-31 2 Updated Product and Remediation details Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

CISA Urges Water and Wastewater Systems Sector to Protect OT Against Activity Targeting PLCs

CISA is currently observing a significant increase in cyber threat actors targeting programmable logic controllers (PLCs) in the Water and Wastewater Systems (WWS) Sector. CISA urges critical infrastructure owners, operators, and integrators to remove publicly exposed PLCs and other operational technology (OT) from the internet as soon as possible. Threat actors targeting exposed PLCs have modified passwords to lock…
Read full source summary
CISA is currently observing a significant increase in cyber threat actors targeting programmable logic controllers (PLCs) in the Water and Wastewater Systems (WWS) Sector. CISA urges critical infrastructure owners, operators, and integrators to remove publicly exposed PLCs and other operational technology (OT) from the internet as soon as possible. Threat actors targeting exposed PLCs have modified passwords to lock out operators and disconnected the PLCs by changing their IP addresses. This activity has resulted in boil water notices and sustained manual operations. These threat actors are targeting water entities of all sizes. Even water organizations with mature cybersecurity processes should validate their external connections, as this targeting activity includes cellular modems installed by operators, vendors, or system integrators that may not be documented or included in routine attack surface scans. OT assets exposed to the internet have an increased risk of defacement, configuration changes, operational disruptions, and, in severe cases, physical damage. CISA recommends organizations implement the following mitigations: Disconnect the PLC from the internet. Remote access for operational purposes should go through a VPN or gateway device, not directly to the PLC. Enable password protection and change default passwords. Allowlist IPs to only allow remote access from known engineering laptops or other critical OT assets. After disconnecting PLCs from the internet, operators should ensure they have a known clean backup of the PLC image in case they are locked out by a modified password. Note: Owners, operators, and integrators of Rockwell Automation MicroLogix 1400 PLCs should see Rockwell Automation’s IMPORTANT NOTICE: Restoring Access to a MicroLogix™ 1400 Controller When the Password Is Unknown for guidance addressing this activity. To securely enable remote access to your OT systems, CISA recommends system owners, operators, and integrators see the following resources for guidance: CISA: Primary Mitigations to Reduce Cyber Threats to Operational Technology United Kingdom's National Cyber Security Center: Secure Connectivity Principles for Operational Technology Federal Bureau of Investigation (FBI): Malicious Cyber Actors Targeting Water and Wastewater Sector Internet Facing Programmable Logic Controllers, Causing Operational Disruptions For additional support, contact the Environmental Protection Agency’s Cybersecurity Technical Assistance Program for the Water Sector or your CISA Regional Office. To report a cyber incident, contact CISA’s 24/7 Operations Center (contact@cisa.dhs.gov), or call 1-844-Say-CISA (1-844-729-2472). Please see Reporting a Cyber Incident for more details or contact FBI’s Internet Crime Complaint Center (IC3) or your local FBI field office. When available, please include the following information regarding the incident: Date, time, and location of the incident Type of activity Number of people affected Type of equipment used for the activity Name of the submitting company or organization, and a designated point of contact Disclaimer The information in this report is being provided “as is” for informational purposes only. CISA does not endorse any commercial entity, product, company, or service, including any entities, products, or services linked within this document. Any reference to specific commercial entities, products, processes, or services by service mark, trademark, manufacturer, or otherwise, does not constitute or imply endorsement, recommendation, or favoring by CISA. Acknowledgements The Environmental Protection Agency and the Federal Bureau of Investigation contributed to this Alert.
· CISA Cybersecurity Advisory

Johnson Controls OpenBlue Employee

View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to upload malicious files, execute stored cross-site scripting attacks, or inject arbitrary HTML content. The following versions of Johnson Controls OpenBlue Employee are affected: OpenBlue Employee (FMS Employee) <=V2025.3.1 (CVE-2026-21662, CVE-2026-34495, CVE-2026-34497) CVSS Vendor Equipment Vulnerabilities v3 2.4 Johnson…
Read full source summary
View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to upload malicious files, execute stored cross-site scripting attacks, or inject arbitrary HTML content. The following versions of Johnson Controls OpenBlue Employee are affected: OpenBlue Employee (FMS Employee) <=V2025.3.1 (CVE-2026-21662, CVE-2026-34495, CVE-2026-34497) CVSS Vendor Equipment Vulnerabilities v3 2.4 Johnson Controls Inc. Johnson Controls OpenBlue Employee Unrestricted Upload of File with Dangerous Type, Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting'), Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS) Background Critical Infrastructure Sectors: Critical Manufacturing, Commercial Facilities, Government Services and Facilities, Transportation Systems, Energy Countries/Areas Deployed: Worldwide Company Headquarters Location: Ireland Vulnerabilities Expand All + CVE-2026-21662 The application does not adequately restrict the types of files that can be uploaded, allowing an attacker to submit files with dangerous content types. Uploaded files may be stored in predictable locations and could be leveraged for further exploitation against the application or its users. View CVE Details Affected Products Johnson Controls OpenBlue Employee Vendor: Johnson Controls Inc. Product Version: Johnson Controls Inc. OpenBlue Employee (FMS Employee): <=V2025.3.1 Product Status: known_affected Remediations Mitigation Johnson Controls recommends the following defensive measures to help reduce the risk of exploitation: Apply the latest product update for OpenBlue Employee (FMS Employee). Customers running V2025.3.1 [LV1.1] or earlier should apply the latest available update. Mitigation Limit application access to authorized users and enforce strong authentication. Mitigation Enable the "Do Not Show Files" location setting if the feature is not being actively used. Mitigation Employ a Web Application Firewall (WAF) to help detect and block malicious requests. Mitigation Investigate and promptly remove any suspicious files or content discovered within the application. Mitigation Limit internet exposure by restricting access to trusted networks or VPN users where practical. Mitigation Review uploaded content periodically and remove content that is no longer required. Mitigation For more detailed mitigation instructions, please see Johnson Controls Product Security Advisory JCI-PSA-2026-09 at the following location: https://www.johnsoncontrols.com/trust-center/cybersecurity/security-advisories https://www.johnsoncontrols.com/trust-center/cybersecurity/security-advisories Relevant CWE: CWE-434 Unrestricted Upload of File with Dangerous Type Metrics CVSS Version Base Score Base Severity Vector String 3.1 2.4 LOW CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:N/I:L/A:N 4.0 4.8 MEDIUM CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:P/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N CVE-2026-34495 Stored XSS occurs when the application improperly handles user input and stores malicious JavaScript code within its database. This script is then rendered and executed whenever another user accesses the compromised page. Unlike reflected XSS, persistent XSS is particularly dangerous because the payload remains active until it is manually removed from the system. View CVE Details Affected Products Johnson Controls OpenBlue Employee Vendor: Johnson Controls Inc. Product Version: Johnson Controls Inc. OpenBlue Employee (FMS Employee): <=V2025.3.1 Product Status: known_affected Remediations Mitigation Johnson Controls recommends the following defensive measures to help reduce the risk of exploitation: Apply the latest product update for OpenBlue Employee (FMS Employee). Customers running V2025.3.1 [LV1.1] or earlier should apply the latest available update. Mitigation Limit application access to authorized users and enforce strong authentication. Mitigation Enable the "Do Not Show Files" location setting if the feature is not being actively used. Mitigation Employ a Web Application Firewall (WAF) to help detect and block malicious requests. Mitigation Investigate and promptly remove any suspicious files or content discovered within the application. Mitigation Limit internet exposure by restricting access to trusted networks or VPN users where practical. Mitigation Review uploaded content periodically and remove content that is no longer required. Mitigation For more detailed mitigation instructions, please see Johnson Controls Product Security Advisory JCI-PSA-2026-09 at the following location: https://www.johnsoncontrols.com/trust-center/cybersecurity/security-advisories https://www.johnsoncontrols.com/trust-center/cybersecurity/security-advisories Relevant CWE: CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') Metrics CVSS Version Base Score Base Severity Vector String 3.1 2.4 LOW CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:N/I:L/A:N 4.0 4.8 MEDIUM CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:P/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N CVE-2026-34497 HTML injection occurs when user-controlled input is embedded into web pages without proper encoding or sanitization, allowing attackers to inject arbitrary HTML markup. This vulnerability enables attackers to manipulate the Document Object Model (DOM) structure and alter the visual presentation of web content. Unlike Cross-Site Scripting (XSS), HTML injection typically involves static HTML content rather than executable JavaScript, though it can serve as a stepping stone to more severe attacks. View CVE Details Affected Products Johnson Controls OpenBlue Employee Vendor: Johnson Controls Inc. Product Version: Johnson Controls Inc. OpenBlue Employee (FMS Employee): <=V2025.3.1 Product Status: known_affected Remediations Mitigation Johnson Controls recommends the following defensive measures to help reduce the risk of exploitation: Apply the latest product update for OpenBlue Employee (FMS Employee). Customers running V2025.3.1 [LV1.1] or earlier should apply the latest available update. Mitigation Limit application access to authorized users and enforce strong authentication. Mitigation Enable the "Do Not Show Files" location setting if the feature is not being actively used. Mitigation Employ a Web Application Firewall (WAF) to help detect and block malicious requests. Mitigation Investigate and promptly remove any suspicious files or content discovered within the application. Mitigation Limit internet exposure by restricting access to trusted networks or VPN users where practical. Mitigation Review uploaded content periodically and remove content that is no longer required. Mitigation For more detailed mitigation instructions, please see Johnson Controls Product Security Advisory JCI-PSA-2026-09 at the following location: https://www.johnsoncontrols.com/trust-center/cybersecurity/security-advisories https://www.johnsoncontrols.com/trust-center/cybersecurity/security-advisories Relevant CWE: CWE-80 Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS) Metrics CVSS Version Base Score Base Severity Vector String 3.1 2.4 LOW CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:N/I:L/A:N 4.0 4.8 MEDIUM CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:P/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N Acknowledgments Johnson Controls reported these vulnerabilities to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. Revision History Initial Release Date: 2026-07-30 Date Revision Summary 2026-07-30 1 Initial Republication of Johnson Controls Inc. Security Advisory JCI-PSA-2026-09 Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Rockwell Automation CompactLogix 5380 ControlLogix 5580 / 1756-EN4TR Communications Module

View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to cause a denial-of-service condition. The following versions of Rockwell Automation CompactLogix 5380 ControlLogix 5580 / 1756-EN4TR Communications Module are affected: ControlLogix 5580 >=V36|<=V37 (CVE-2026-9636) CompactLogix 5380 >=V36|<=V37 (CVE-2026-9636) GuardLogix 5580 >=V36|<=V37 (CVE-2026-9636) Compact GuardLogix 5380…
Read full source summary
View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to cause a denial-of-service condition. The following versions of Rockwell Automation CompactLogix 5380 ControlLogix 5580 / 1756-EN4TR Communications Module are affected: ControlLogix 5580 >=V36|<=V37 (CVE-2026-9636) CompactLogix 5380 >=V36|<=V37 (CVE-2026-9636) GuardLogix 5580 >=V36|<=V37 (CVE-2026-9636) Compact GuardLogix 5380 >=V36|<=V37 (CVE-2026-9636) 1756-EN4TR V6.001 (CVE-2026-9636) 1756-EN4TR V7.001 (CVE-2026-9636) CVSS Vendor Equipment Vulnerabilities v3 5.9 Rockwell Automation Rockwell Automation CompactLogix 5380 ControlLogix 5580 / 1756-EN4TR Communications Module Improper Check for Certificate Revocation Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2026-9636 A security issue exists within CompactLogix 5380, ControlLogix 5580, and EN4TR communication modules related to CIP Security certificate revocation handling. The security issue stems from the controller failing to properly reject certificates signed by an intermediate certificate that has been revoked via a Certificate Revocation List (CRL). This could allow a network-based attacker to establish a connection using a certificate that should be untrusted, potentially bypassing CIP Security protections. View CVE Details Affected Products Rockwell Automation CompactLogix 5380 ControlLogix 5580 / 1756-EN4TR Communications Module Vendor: Rockwell Automation Product Version: Rockwell Automation ControlLogix 5580: >=V36|<=V37, Rockwell Automation CompactLogix 5380: >=V36|<=V37, Rockwell Automation GuardLogix 5580: >=V36|<=V37, Rockwell Automation Compact GuardLogix 5380: >=V36|<=V37, Rockwell Automation 1756-EN4TR: V6.001, Rockwell Automation 1756-EN4TR: V7.001 Product Status: known_affected Remediations Vendor fix Rockwell Automation recommend users update to the following versions: ControlLogix 5580: Update to V38.011 Vendor fix CompactLogix 5380: Update to V38.011 Vendor fix GuardLogix 5580: Update to V38.011 Vendor fix Compact GuardLogix 5380: Update to V38.011 Vendor fix 1756-EN4TR: Update to V8.001 Relevant CWE: CWE-299 Improper Check for Certificate Revocation Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.9 MEDIUM CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N 4.0 8.2 HIGH CVSS:4.0/AV:N/AC:H/AT:P/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N Acknowledgments Rockwell Automation reported this vulnerability to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. Revision History Initial Release Date: 2026-07-30 Date Revision Summary 2026-07-30 1 Initial Publication Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

MZ Automation lib60870

View CSAF Summary Successful exploitation of these vulnerabilities could crash the device being accessed. The following versions of MZ Automation lib60870 are affected: lib60870 2.4.0 (CVE-2026-61893, CVE-2026-63033) CVSS Vendor Equipment Vulnerabilities v3 6.5 MZ Automation GmbH MZ Automation lib60870 Out-of-bounds Read Background Critical Infrastructure Sectors: Energy, Water and Wastewater, Critical…
Read full source summary
View CSAF Summary Successful exploitation of these vulnerabilities could crash the device being accessed. The following versions of MZ Automation lib60870 are affected: lib60870 2.4.0 (CVE-2026-61893, CVE-2026-63033) CVSS Vendor Equipment Vulnerabilities v3 6.5 MZ Automation GmbH MZ Automation lib60870 Out-of-bounds Read Background Critical Infrastructure Sectors: Energy, Water and Wastewater, Critical Manufacturing, Chemical Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities Expand All + CVE-2026-61893 A crafted IEC 60870-5-104 I-frame with TypeID 104 (C_TS_NA_1) and an inflated object count causes TestCommand_getFromBuffer to read one byte past the end of the heap-allocated message buffer. View CVE Details Affected Products MZ Automation lib60870 Vendor: MZ Automation GmbH Product Version: MZ Automation GmbH lib60870: 2.4.0 Product Status: known_affected Remediations Mitigation MZ Automation recommends users update to version 2.4.1 when available. Vendor fix See MZ Automation advisories for more information: https://github.com/mz-automation/lib60870/security/advisories/GHSA-g3w7-x5rx-83xm https://github.com/mz-automation/lib60870/security/advisories/GHSA-g3w7-x5rx-83xm Relevant CWE: CWE-125 Out-of-bounds Read Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:L 4.0 6.9 MEDIUM CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:L/SC:N/SI:N/SA:N CVE-2026-63033 A crafted IEC 60870-5-104 I-frame with a declared object count exceeding what fits in the ASDU body causes InformationObject_ParseObjectAddress to read one byte past the end of the heap-allocated message buffer. View CVE Details Affected Products MZ Automation lib60870 Vendor: MZ Automation GmbH Product Version: MZ Automation GmbH lib60870: 2.4.0 Product Status: known_affected Remediations Mitigation MZ Automation recommends users update to version 2.4.1 when available. Vendor fix See MZ Automation advisory for more information: https://github.com/mz-automation/lib60870/security/advisories/GHSA-7v97-jmwv-w5j7 https://github.com/mz-automation/lib60870/security/advisories/GHSA-7v97-jmwv-w5j7 Relevant CWE: CWE-125 Out-of-bounds Read Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:L 4.0 6.9 MEDIUM CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:L/SC:N/SI:N/SA:N Acknowledgments arun babu puthuparambil of Central Power Research Institute, Bengaluru, India reported these vulnerabilities to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as virtual private networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. Revision History Initial Release Date: 2026-07-30 Date Revision Summary 2026-07-30 1 Initial Publication Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

Open Source Software: Security Principles and Practices

Open source software (OSS) is embedded in nearly every modern system, from business applications to critical infrastructure. Our new Open Source Software: Security Principles and Practices guidance helps agencies securely use, evaluate, and publish open source software. It covers OSS risk management across the full lifecycle, introduces the C4 Framework for trust assessment, and provides specific recommendations for…
Read full source summary
Open source software (OSS) is embedded in nearly every modern system, from business applications to critical infrastructure. Our new Open Source Software: Security Principles and Practices guidance helps agencies securely use, evaluate, and publish open source software. It covers OSS risk management across the full lifecycle, introduces the C4 Framework for trust assessment, and provides specific recommendations for vulnerability management, software bill of materials use, secure development, and handling open source artificial intelligence systems. Visit CISA’s Open Source Security webpage for more resources. CISA is committed to providing access to our web pages and documents for individuals with disabilities, both members of the public and federal employees. If the format of any elements or content within this document interferes with your ability to access the information, as defined in the Rehabilitation Act, please email opensource@cisa.dhs.gov. To enable us to respond in a manner most helpful to you, please indicate the nature of your accessibility problem and the preferred format in which to receive the material. Please share your thoughts! We welcome your feedback. CISA Product Survey
· CISA Cybersecurity Advisory

o6 Automation open62541

View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to disclose sensitive information, cause a denial of service, or potentially execute arbitrary code. The following versions of o6 Automation open62541 are affected: open62541 on Windows and Linux >=from_1.3.0|<=1.3.17 (CVE-2026-63362, CVE-2026-65423, CVE-2026-63035, CVE-2026-63559) open62541 on Windows and Linux…
Read full source summary
View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to disclose sensitive information, cause a denial of service, or potentially execute arbitrary code. The following versions of o6 Automation open62541 are affected: open62541 on Windows and Linux >=from_1.3.0|<=1.3.17 (CVE-2026-63362, CVE-2026-65423, CVE-2026-63035, CVE-2026-63559) open62541 on Windows and Linux >=from_1.4.0|<=1.4.16 (CVE-2026-63362, CVE-2026-65423, CVE-2026-63035, CVE-2026-63559) open62541 on Windows and Linux >=from_1.5.0|<=1.5.4 (CVE-2026-63362, CVE-2026-65423, CVE-2026-63035, CVE-2026-63559) open62541 on Windows and Linux master (CVE-2026-63362, CVE-2026-65423, CVE-2026-63035, CVE-2026-63559) CVSS Vendor Equipment Vulnerabilities v3 8.8 o6 Automation GmbH o6 Automation open62541 Integer Underflow (Wrap or Wraparound), Integer Overflow or Wraparound, Use After Free Background Critical Infrastructure Sectors: Critical Manufacturing, Energy, Transportation Systems Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities Expand All + CVE-2026-63362 An unsigned integer underflow in the PubSub signature verification path in open62541 may allow a remote attacker to cause a denial of service via a crafted UDP packet. View CVE Details Affected Products o6 Automation open62541 Vendor: o6 Automation GmbH Product Version: o6 Automation GmbH open62541 on Windows and Linux: >=from_1.3.0|<=1.3.17, o6 Automation GmbH open62541 on Windows and Linux: >=from_1.4.0|<=1.4.16, o6 Automation GmbH open62541 on Windows and Linux: >=from_1.5.0|<=1.5.4, o6 Automation GmbH open62541 on Windows and Linux: master Product Status: known_affected Remediations Mitigation o6 Automation has prepared mitigations and fixes to address these issues and recommends that users update to the newest version. The new version can be obtained by contacting o6 Automation https://www.o6-automation.com/contact or by downloading from the following locations: https://www.o6-automation.com/contact Mitigation https://github.com/open62541/open62541/pull/8235/commits/b666d35769ce63998442e4d0810a3fb10b50179f https://github.com/open62541/open62541/pull/8235/commits/b666d35769ce63998442e4d0810a3fb10b50179f Mitigation https://github.com/open62541/open62541/pull/8236/commits/06b99fef667c8ec5bdf0605b4f00c84fcc1d3a60 https://github.com/open62541/open62541/pull/8236/commits/06b99fef667c8ec5bdf0605b4f00c84fcc1d3a60 Mitigation https://github.com/open62541/open62541/pull/8237/commits/1b71d9c5d9c4d02d4729b8903a52e9f530bf804e https://github.com/open62541/open62541/pull/8237/commits/1b71d9c5d9c4d02d4729b8903a52e9f530bf804e Mitigation https://github.com/open62541/open62541/pull/8238/commits/afab4107bfd161da9ce8bb30ed77f3968c9c97df https://github.com/open62541/open62541/pull/8238/commits/afab4107bfd161da9ce8bb30ed77f3968c9c97df Mitigation For more information, see open62541 Security Advisories SA-2026-0012, SA-2026-0014, and SA-2026-0015 or contact o6 Automation: https://www.o6-automation.com/contact https://www.o6-automation.com/contact Relevant CWE: CWE-191 Integer Underflow (Wrap or Wraparound) Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.9 MEDIUM CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H 4.0 8.2 HIGH CVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N CVE-2026-65423 An integer overflow in the UA_Variant arrayDimensions product computation in open62541 may allow a remote attacker to trigger an out-of-bounds write. View CVE Details Affected Products o6 Automation open62541 Vendor: o6 Automation GmbH Product Version: o6 Automation GmbH open62541 on Windows and Linux: >=from_1.3.0|<=1.3.17, o6 Automation GmbH open62541 on Windows and Linux: >=from_1.4.0|<=1.4.16, o6 Automation GmbH open62541 on Windows and Linux: >=from_1.5.0|<=1.5.4, o6 Automation GmbH open62541 on Windows and Linux: master Product Status: known_affected Remediations Mitigation o6 Automation has prepared mitigations and fixes to address these issues and recommends that users update to the newest version. The new version can be obtained by contacting o6 Automation https://www.o6-automation.com/contact or by downloading from the following locations: https://www.o6-automation.com/contact Mitigation https://github.com/open62541/open62541/pull/8235/commits/b666d35769ce63998442e4d0810a3fb10b50179f https://github.com/open62541/open62541/pull/8235/commits/b666d35769ce63998442e4d0810a3fb10b50179f Mitigation https://github.com/open62541/open62541/pull/8236/commits/06b99fef667c8ec5bdf0605b4f00c84fcc1d3a60 https://github.com/open62541/open62541/pull/8236/commits/06b99fef667c8ec5bdf0605b4f00c84fcc1d3a60 Mitigation https://github.com/open62541/open62541/pull/8237/commits/1b71d9c5d9c4d02d4729b8903a52e9f530bf804e https://github.com/open62541/open62541/pull/8237/commits/1b71d9c5d9c4d02d4729b8903a52e9f530bf804e Mitigation https://github.com/open62541/open62541/pull/8238/commits/afab4107bfd161da9ce8bb30ed77f3968c9c97df https://github.com/open62541/open62541/pull/8238/commits/afab4107bfd161da9ce8bb30ed77f3968c9c97df Mitigation For more information, see open62541 Security Advisories SA-2026-0012, SA-2026-0014, and SA-2026-0015 or contact o6 Automation: https://www.o6-automation.com/contact https://www.o6-automation.com/contact Relevant CWE: CWE-190 Integer Overflow or Wraparound Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.8 HIGH CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H 4.0 8.7 HIGH CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N CVE-2026-63035 A heap use-after-free vulnerability in the TransferSubscriptions service in open62541 may allow an authenticated attacker to cause a denial of service or potentially execute arbitrary code. View CVE Details Affected Products o6 Automation open62541 Vendor: o6 Automation GmbH Product Version: o6 Automation GmbH open62541 on Windows and Linux: >=from_1.3.0|<=1.3.17, o6 Automation GmbH open62541 on Windows and Linux: >=from_1.4.0|<=1.4.16, o6 Automation GmbH open62541 on Windows and Linux: >=from_1.5.0|<=1.5.4, o6 Automation GmbH open62541 on Windows and Linux: master Product Status: known_affected Remediations Mitigation o6 Automation has prepared mitigations and fixes to address these issues and recommends that users update to the newest version. The new version can be obtained by contacting o6 Automation https://www.o6-automation.com/contact or by downloading from the following locations: https://www.o6-automation.com/contact Mitigation https://github.com/open62541/open62541/pull/8235/commits/b666d35769ce63998442e4d0810a3fb10b50179f https://github.com/open62541/open62541/pull/8235/commits/b666d35769ce63998442e4d0810a3fb10b50179f Mitigation https://github.com/open62541/open62541/pull/8236/commits/06b99fef667c8ec5bdf0605b4f00c84fcc1d3a60 https://github.com/open62541/open62541/pull/8236/commits/06b99fef667c8ec5bdf0605b4f00c84fcc1d3a60 Mitigation https://github.com/open62541/open62541/pull/8237/commits/1b71d9c5d9c4d02d4729b8903a52e9f530bf804e https://github.com/open62541/open62541/pull/8237/commits/1b71d9c5d9c4d02d4729b8903a52e9f530bf804e Mitigation https://github.com/open62541/open62541/pull/8238/commits/afab4107bfd161da9ce8bb30ed77f3968c9c97df https://github.com/open62541/open62541/pull/8238/commits/afab4107bfd161da9ce8bb30ed77f3968c9c97df Mitigation For more information, see open62541 Security Advisories SA-2026-0012, SA-2026-0014, and SA-2026-0015 or contact o6 Automation: https://www.o6-automation.com/contact https://www.o6-automation.com/contact Relevant CWE: CWE-416 Use After Free Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.1 HIGH CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H 4.0 7.2 HIGH CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N CVE-2026-63559 An integer overflow in the UA_Variant arrayDimensions product computation in open62541 may allow a remote attacker to read out-of-bounds heap memory, potentially disclosing sensitive information. View CVE Details Affected Products o6 Automation open62541 Vendor: o6 Automation GmbH Product Version: o6 Automation GmbH open62541 on Windows and Linux: >=from_1.3.0|<=1.3.17, o6 Automation GmbH open62541 on Windows and Linux: >=from_1.4.0|<=1.4.16, o6 Automation GmbH open62541 on Windows and Linux: >=from_1.5.0|<=1.5.4, o6 Automation GmbH open62541 on Windows and Linux: master Product Status: known_affected Remediations Mitigation o6 Automation has prepared mitigations and fixes to address these issues and recommends that users update to the newest version. The new version can be obtained by contacting o6 Automation https://www.o6-automation.com/contact or by downloading from the following locations: https://www.o6-automation.com/contact Mitigation https://github.com/open62541/open62541/pull/8235/commits/b666d35769ce63998442e4d0810a3fb10b50179f https://github.com/open62541/open62541/pull/8235/commits/b666d35769ce63998442e4d0810a3fb10b50179f Mitigation https://github.com/open62541/open62541/pull/8236/commits/06b99fef667c8ec5bdf0605b4f00c84fcc1d3a60 https://github.com/open62541/open62541/pull/8236/commits/06b99fef667c8ec5bdf0605b4f00c84fcc1d3a60 Mitigation https://github.com/open62541/open62541/pull/8237/commits/1b71d9c5d9c4d02d4729b8903a52e9f530bf804e https://github.com/open62541/open62541/pull/8237/commits/1b71d9c5d9c4d02d4729b8903a52e9f530bf804e Mitigation https://github.com/open62541/open62541/pull/8238/commits/afab4107bfd161da9ce8bb30ed77f3968c9c97df https://github.com/open62541/open62541/pull/8238/commits/afab4107bfd161da9ce8bb30ed77f3968c9c97df Mitigation For more information, see open62541 Security Advisories SA-2026-0012, SA-2026-0014, and SA-2026-0015 or contact o6 Automation: https://www.o6-automation.com/contact https://www.o6-automation.com/contact Relevant CWE: CWE-190 Integer Overflow or Wraparound Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N 4.0 8.7 HIGH CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N Acknowledgments Asher Davila and Malav Vyas of Palo Alto Networks reported these vulnerabilities to CISA Abhinav Agarwal reported these vulnerabilities to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as virtual private networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. Revision History Initial Release Date: 2026-07-30 Date Revision Summary 2026-07-30 1 Initial Publication Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

NASA Core Flight System (cFS) Health & Safety (HS) Application

View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to cause a denial-of-service condition. The following versions of NASA Core Flight System (cFS) Health & Safety (HS) Application are affected: Core Flight System (cFS) Health & Safety (HS) Application <=v7.0.1 (CVE-2026-18064) CVSS Vendor Equipment Vulnerabilities v3 7.5 NASA NASA Core Flight System (cFS) Health & Safety (HS)…
Read full source summary
View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to cause a denial-of-service condition. The following versions of NASA Core Flight System (cFS) Health & Safety (HS) Application are affected: Core Flight System (cFS) Health & Safety (HS) Application <=v7.0.1 (CVE-2026-18064) CVSS Vendor Equipment Vulnerabilities v3 7.5 NASA NASA Core Flight System (cFS) Health & Safety (HS) Application NULL Pointer Dereference Background Critical Infrastructure Sectors: Transportation Systems Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2026-18064 An incomplete fix for CVE-2026-15352 in the NASA core Flight System (cFS) Health and Safety (HS) application leaves a separate NULL pointer dereference reachable in versions through 7.0.1. An attacker who can trigger the affected command under specific conditions could cause the HS application to crash, resulting in a denial-of-service condition and processor reset. View CVE Details Affected Products NASA Core Flight System (cFS) Health & Safety (HS) Application Vendor: NASA Product Version: NASA Core Flight System (cFS) Health & Safety (HS) Application: <=v7.0.1 Product Status: known_affected Remediations Mitigation NASA reports that an official fix is currently under development and is expected to be included in a future software release. Mitigation As an interim mitigation, users can update their HS app from the HS repo (https://github.com/nasa/HS) to the latest dev branch. The fix is in the dev branch starting at commit 828855f971db4b6714367ed0a970f52dbeab2965 https://github.com/nasa/HS Relevant CWE: CWE-476 NULL Pointer Dereference Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H 4.0 8.2 HIGH CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N Acknowledgments Michael Holmquist of Hasp Labs reported this vulnerability to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. Revision History Initial Release Date: 2026-07-30 Date Revision Summary 2026-07-30 1 Initial Publication Legal Notice and Terms of Use
· CISA Cybersecurity Advisory

2026 Minimum Elements for a Software Bill of Materials (SBOM)

CISA, the National Security Agency, the Federal Bureau of Investigation, and international partners released joint guidance, 2026 Minimum Elements for a Software Bill of Materials (SBOM), that updates and replaces the minimum elements for an SBOM published by the National Telecommunications and Information Administration (NTIA) in 2021. The new guidance incorporates stakeholder feedback from a 2025 public comment…
Read full source summary
CISA, the National Security Agency, the Federal Bureau of Investigation, and international partners released joint guidance, 2026 Minimum Elements for a Software Bill of Materials (SBOM), that updates and replaces the minimum elements for an SBOM published by the National Telecommunications and Information Administration (NTIA) in 2021. The new guidance incorporates stakeholder feedback from a 2025 public comment period and reflects current SBOM tools and needs while preserving the core principles of the original NTIA document. An SBOM serves as an “ingredients list” for software and is a key building block of software security and supply chain risk management. Organizations can use SBOM data to better understand the makeup of their software components and supply chains and make more risk-informed decisions. Minimum elements for an SBOM describe the baseline technologies and practices that an SBOM should include. While the minimum elements for an SBOM apply to all software, some software types—such as artificial intelligence and software as a service in cloud environments—may require additional elements. Any effort to improve software transparency, regardless of the software type, should begin with the application of minimum elements.
· CISA Cybersecurity Advisory

CISA Adds One Known Exploited Vulnerability to Catalog

CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-20316 Cisco Secure Firewall Management Center Use of Hard-coded Password Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 26-04:…
Read full source summary
CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-20316 Cisco Secure Firewall Management Center Use of Hard-coded Password Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 26-04: Prioritizing Security Updates Based on Risk establishes vulnerability management requirements for Federal Civilian Executive Branch (FCEB) agencies. BOD 26-04 reinforces the importance of the KEV Catalog and requires federal agencies to prioritize rapid remediation of high-risk vulnerabilities, specifically those identified by Common Vulnerabilities and Exposures (CVEs) listed in CISA’s KEV Catalog on publicly exposed assets that grant total control of the asset post-exploitation, while deferring action for lower-risk vulnerabilities. BOD 26-04 further establishes basic expectations for when agencies must check whether threat actors compromised the system before the patch was applied. While BOD 26-04 applies only to FCEB agencies, CISA encourages all organizations to adopt risk-based vulnerability management and prioritize remediation of KEV Catalog vulnerabilities. CISA will continue to add vulnerabilities to the catalog that meet the specified criteria. Aware of an exploited vulnerability not currently listed in the KEV Catalog? Submit it for potential addition through CISA’s KEV Nomination Form. Potential KEV additions must have a CVE ID, evidence of exploitation, and clear mitigation guidance.
Browse saved snapshots