View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to tamper with serialized data, potentially resulting in code execution during deserialization. The following versions of AVEVA Enterprise SCADA are affected: Enterprise SCADA 2025 (CVE-2025-7639) Enterprise SCADA >=2024|<=2024_SP1_P01 (CVE-2025-7639) Enterprise SCADA >=2023|<=2023_SP1 (CVE-2025-7639) Enterprise SCADA…
Read more of the source summary
>=2022|<=2022_SP2_P2 (CVE-2025-7639) Enterprise SCADA <=2021_SP2_P5 (CVE-2025-7639) Enterprise SCADA HMI 2024|2024|R2 (CVE-2025-7639) Enterprise SCADA HMI <=2023_P1 (CVE-2025-7639) CVSS Vendor Equipment Vulnerabilities v3 7.1 AVEVA AVEVA Enterprise SCADA Deserialization of Untrusted Data Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: United Kingdom Vulnerabilities Expand All + CVE-2025-7639 The vulnerability, if exploited, could allow an authenticated miscreant with "DNA Authority - Operator" privilege to tamper with serialized data, potentially resulting in code execution during deserialization under the privilege of Enterprise SCADA security group "DNA Apps". View CVE Details Affected Products…
View CSAF Summary Hitachi Energy is aware of Dirty Frag vulnerabilities that affect APM Edge product versions listed in this document. Successful exploitation of these vulnerabilities could result in impact on confidentiality, integrity and availability of the product. Please refer to the Recommended Immediate Actions for information about the mitigation/remediation. The following versions of Hitachi Energy APM Edge…
Read more of the source summary
Product are affected: APM Edge vers:APM_Edge/<=6.10 (CVE-2026-43284, CVE-2026-43500) CVSS Vendor Equipment Vulnerabilities v3 8.8 Hitachi Energy Hitachi Energy APM Edge Product Write-what-where Condition, Out-of-bounds Write Background Critical Infrastructure Sectors: Energy Countries/Areas Deployed: Worldwide Company Headquarters Location: Switzerland Vulnerabilities Expand All + CVE-2026-43284 CWE-123: Write-what-where Condition A vulnerability exists in the IPsec ESP subsystem (esp4, esp6) of the Linux kernel used in APM Edge that allows a local unprivileged user to escalate privileges to root. The flaw exists in how the kernel handles memory pages when processing ESP encrypted network packets. An attacker can craft a packet that causes the kernel to decrypt data…
View CSAF Summary Successful exploitation of this vulnerability may allow an attacker to inject and execute arbitrary OS commands with root privileges. The following versions of Haiwell IoT Cloud HMI Gateway are affected: Haiwell IoT Cloud HMI Gateway 3.40.1.12 (CVE-2026-19188) CVSS Vendor Equipment Vulnerabilities v3 10 Haiwell Haiwell IoT Cloud HMI Gateway Improper Neutralization of Special Elements used in an OS…
Read more of the source summary
Command ('OS Command Injection') Background Critical Infrastructure Sectors: Energy, Critical Manufacturing, Water and Wastewater Countries/Areas Deployed: Worldwide Company Headquarters Location: China Vulnerabilities Expand All + CVE-2026-19188 A critical OS command injection vulnerability has been identified in the Haiwell IoT Cloud HMI Gateway product. The vulnerability exists in the Net Check feature accessible via the /setting endpoint. The cmdPing Socket.io event fails to properly sanitize user-supplied input before passing it to the underlying operating system, allowing an attacker to inject and execute arbitrary OS commands with root privileges View CVE Details Affected Products Haiwell IoT Cloud HMI Gateway Vendor: Haiwell Product Version: Haiwell Haiwell IoT…
View CSAF Summary Parasolid is affected by an out of bounds read vulnerability that could be triggered when the application reads files in X_T format. This could allow an attacker to crash the application or execute arbitrary code. Siemens has released new versions for the affected products and recommends to update to the latest versions. The following versions of Siemens Parasolid are affected: Parasolid V38.0…
Read more of the source summary
vers:intdot/<38.0.235 (CVE-2026-64629) Parasolid V38.1 vers:intdot/<38.1.230 (CVE-2026-64629) CVSS Vendor Equipment Vulnerabilities v3 7.8 Siemens Siemens Parasolid Out-of-bounds Read Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities Expand All + CVE-2026-64629 The affected applications contains an out of bounds read vulnerability while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. View CVE Details Affected Products Siemens Parasolid Vendor: Siemens Product Version: Parasolid V38.0 < V38.0.235, Parasolid V38.1 < V38.1.230 Product Status: known_affected Remediations Vendor fix Update to…
View CSAF Summary Fortinet has published information on vulnerabilities in FortiOS. This advisory lists the related Siemens Industrial products. Siemens recommends to contact customer support for additional information, and follow Fortinet advisory for workarounds and mitigation measures. The following versions of Siemens RUGGEDCOM APE1808 are affected: RUGGEDCOM APE1808 vers:all/* (CVE-2026-23573, CVE-2026-59839)…
Read more of the source summary
CVSS Vendor Equipment Vulnerabilities v3 6.1 Siemens Siemens RUGGEDCOM APE1808 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting'), Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') Background Critical Infrastructure Sectors: Critical Manufacturing, Energy, Transportation Systems Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities Expand All + CVE-2026-23573 An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability [CWE-79] vulnerability in Fortinet FortiOS 7.6.0 through 7.6.6, FortiOS 7.4 all versions, FortiOS 7.2 all versions, FortiPAM 1.8.0, FortiPAM 1.7 all versions, FortiPAM 1.6 all versions, FortiPAM 1.5 all versions,…
View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker with network access to achieve remote code execution. The following versions of Johnson Controls C-CURE 9000 and Victor application server (Update A) are affected: C-CURE 9000 <=v3.10.1 (CVE-2026-21655) victor Application Server <=v4.10 (CVE-2026-21655) victor <=v7.0 (CVE-2026-21655) victor Web victor Web <=v7.1…
Read more of the source summary
(CVE-2026-34496) CVSS Vendor Equipment Vulnerabilities v3 9.6 Johnson Controls Johnson Controls C-CURE 9000 and Victor application server (Update A) Server-Side Request Forgery (SSRF), Execution with Unnecessary Privileges Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Ireland Vulnerabilities Expand All + CVE-2026-21655 Under certain circumstances, successful exploitation of this vulnerability could allow an unauthenticated attacker on an adjacent network to achieve arbitrary code execution on the C-CURE 9000, victor application server and victor, as well as connected clients (e.g., workstations of physical security personnel). Such attack could impact physical security controls. View CVE Details…
View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to access unauthorized health profile information, make changes to health information, cause a denial-of-service condition, disclose session token information, and obtain control of user accounts. The following versions of Mira Hormone Monitor, Mira Android App are affected: Mira Monitor Firmware 1.7.1.47 (CVE-2026-66875,…
Read more of the source summary
CVE-2026-66098, CVE-2026-67558, CVE-2026-67568, CVE-2026-68067, CVE-2026-66340, CVE-2026-64934, CVE-2026-66832) Mira Android App 4.5.15.4 (CVE-2026-66875, CVE-2026-66098, CVE-2026-67558, CVE-2026-67568, CVE-2026-68067, CVE-2026-66340, CVE-2026-64934, CVE-2026-66832) CVSS Vendor Equipment Vulnerabilities v3 9.8 Quanovate Tech Inc. (operating as Mira / Mira Care) Mira Hormone Monitor, Mira Android App Missing Authentication for Critical Function, Authentication Bypass by Spoofing, Use of Hard-coded Credentials, Weak Authentication, Improper Restriction of Excessive Authentication Attempts, Reliance on Untrusted Inputs in a Security Decision, Use of GET Request Method With Sensitive Query Strings Background Critical Infrastructure Sectors: Healthcare and Public Health…
CISA has added three new vulnerabilities to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-20349 Cisco Secure Firewall Adaptive Security Appliance (ASA) and Firewall Threat Defense (FTD) Heap Inspection Vulnerability CVE-2026-68820 Microsoft Windows Ancillary Function Driver for WinSock Use-After-Free Vulnerability CVE-2026-72898 Metabase SQL Injection…
Read more of the source summary
Vulnerability These types of vulnerabilities are a frequent attack vector for malicious cyber actors and pose significant risks to the federal enterprise. Binding Operational Directive (BOD) 26-04: Prioritizing Security Updates Based on Risk establishes vulnerability management requirements for Federal Civilian Executive Branch (FCEB) agencies. BOD 26-04 reinforces the importance of the KEV Catalog and requires federal agencies to prioritize rapid remediation of high-risk vulnerabilities, specifically those identified by Common Vulnerabilities and Exposures (CVEs) listed in CISA’s KEV Catalog on publicly exposed assets that grant total control of the asset post-exploitation, while deferring action for lower-risk vulnerabilities. BOD 26-04 further establishes basic expectations…
View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to use hidden commands to disable electrical safety mechanisms or modify other stimulation output settings. The following versions of Pulsetto Vagus Nerve Stimulator are affected: Pulsetto Vagus Nerve Stimulator vers:all/* (CVE-2026-18844) CVSS Vendor Equipment Vulnerabilities v3 8.1 Pulsetto Pulsetto Vagus Nerve Stimulator…
Read more of the source summary
Hidden Functionality Background Critical Infrastructure Sectors: Healthcare and Public Health Countries/Areas Deployed: Worldwide Company Headquarters Location: Lithuania Vulnerabilities Expand All + CVE-2026-18844 The firmware of the affected product accepts several undisclosed commands over its Bluetooth Low Energy (BLE) interface. These commands are sent without authentication or encryption, and are never issued by the companion mobile application, yet are fully processed by the device when it is powered on. View CVE Details Affected Products Pulsetto Vagus Nerve Stimulator Vendor: Pulsetto Product Version: Pulsetto Pulsetto Vagus Nerve Stimulator: vers:all/* Product Status: known_affected Remediations Mitigation Pulsetto has not responded to requests to work with CISA to…
Advisory at a Glance Title #StopRansomware: Gunra Ransomware Original Publication August 10, 2026 Executive Summary Gunra is a ransomware-as-a-service (RaaS) used by affiliates to target government, critical infrastructure, and other organizations. The Gunra ransomware variant first appeared in 2025 and expanded to RaaS operations in 2026. The actors leverage a double-extortion model, both encrypting data and…
Read more of the source summary
threatening to publish exfiltrated data to a dedicated leak site (DLS) if the ransom is not paid. This advisory provides technical details of the activity, as well as tailored detection and mitigation guidance to protect at-risk organizations from Gunra. Key Actions Prioritize patching known exploited vulnerabilities in internet-facing systems, including virtual private network (VPN) gateways and remote desktop protocol (RDP)-exposed infrastructure. Implement and test offline, immutable backups stored in a physically separate, segmented location to ensure recoverability without ransom payment. Segment networks to restrict lateral movement from an initially compromised device to other systems in the organization. Indicators of Compromise For a downloadable copy of indicators…
BioThreat brings together reports from the listed public sources. Open the linked title to read the publisher’s original report and any later corrections. Third-party reports retain their own rights and licenses.
A source date is the date the publisher issued or updated a report. A snapshot date is the day BioThreat collected a copy of the feed. The same report can appear in multiple snapshots, and some days have no saved copy.
Open a feed or saved snapshot for original links and machine-readable JSON, where available. Use MERIDIAN to compare reporting across sources and dates.