CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2025-62593 Ray-Project Ray Code Injection Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 26-04: Prioritizing Security Updates Based on Risk…
Read more of the source summary
establishes vulnerability management requirements for Federal Civilian Executive Branch (FCEB) agencies. BOD 26-04 reinforces the importance of the KEV Catalog and requires federal agencies to prioritize rapid remediation of high-risk vulnerabilities, specifically those identified by Common Vulnerabilities and Exposures (CVEs) listed in CISA’s KEV Catalog on publicly exposed assets that grant total control of the asset post-exploitation, while deferring action for lower-risk vulnerabilities. BOD 26-04 further establishes basic expectations for when agencies must check whether threat actors compromised the system before the patch was applied. While BOD 26-04 applies only to FCEB agencies, CISA encourages all organizations to adopt risk-based vulnerability management and…
View CSAF Summary Siemens LOGO! Soft Comfort contains multiple vulnerabilities in its project-file encryption and password handling mechanisms. A local attacker could exploit these vulnerabilities to extract the master key, allowing them to decrypt project data or remove project passwords. The lack of password salting enables offline dictionary or brute-force attacks against the password hashes. Successful…
Read more of the source summary
exploitation could result in unauthorized access to, or modification of, sensitive project logic and configurations. Siemens has released a new version for LOGO! Soft Comfort and recommends to update to the latest version. The following versions of Siemens LOGO! Soft Comfort are affected: LOGO! Soft Comfort vers:intdot/<9 (CVE-2026-57262, CVE-2026-57263) CVSS Vendor Equipment Vulnerabilities v3 6.8 Siemens Siemens LOGO! Soft Comfort Use of Hard-coded Cryptographic Key, Use of a One-Way Hash without a Salt Background Critical Infrastructure Sectors: Commercial Facilities, Transportation Systems Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities Expand All + CVE-2026-57262 Affected products use a static, hardcoded AES master key to encrypt…
View CSAF Summary Successful exploitation of this vulnerability could allow an attacker within Bluetooth range to manipulate brain stimulation parameters and override safety limits. The following versions of Flow Neuroscience FL-100 are affected: Flow Neuroscience FL-100 Halo Neuroscience FL-100 CVSS Vendor Equipment Vulnerabilities v3 8.1 Flow Neuroscience Flow Neuroscience FL-100 Use of Hard-coded Credentials…
Read more of the source summary
Background Critical Infrastructure Sectors: Healthcare and Public Health Countries/Areas Deployed: Worldwide Company Headquarters Location: Sweden Vulnerabilities Expand All + CVE-2026-18164 An undocumented hard-coded credential, shared by all device units, is authorized to bypass authentication. This allows an attacker within Bluetooth range to arbitrarilymanipulate brain stimulation parameters and state. View CVE Details Affected Products Flow Neuroscience FL-100 Vendor: Flow Neuroscience Product Version: Flow Neuroscience Flow Neuroscience FL-100: <July_2026, Flow Neuroscience Halo Neuroscience FL-100: <July_2026 Product Status: known_affected Remediations Mitigation Users are encouraged to install the latest firmware updates provided by Flow Neuroscience via the Flow…
View CSAF Summary Solid Edge is affected by multiple file parsing vulnerabilities that could be triggered when the application reads specially crafted files in PAR, PSM or DFT format. This could allow an attacker to crash the application or execute arbitrary code. Siemens has released new versions for the affected products and recommends to update to the latest versions. The following versions of Siemens Solid Edge…
Read more of the source summary
are affected: Solid Edge SE2025 vers:intdot/<225.0.15 (CVE-2026-50058, CVE-2026-50059, CVE-2026-50060, CVE-2026-50061, CVE-2026-50062, CVE-2026-50063, CVE-2026-50064) Solid Edge SE2026 vers:intdot/<226.0.7 (CVE-2026-50058, CVE-2026-50059, CVE-2026-50060, CVE-2026-50061, CVE-2026-50062, CVE-2026-50063, CVE-2026-50064) CVSS Vendor Equipment Vulnerabilities v3 7.8 Siemens Siemens Solid Edge Out-of-bounds Read, Out-of-bounds Write, Use After Free Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities Expand All + CVE-2026-50058 The affected applications contains an out of bounds read vulnerability while parsing specially crafted DFT files. This could allow an attacker to…
View CSAF Summary Successful exploitation of this vulnerability could allow a low-privilege user or attacker to inject a persistent malicious payload via a crafted URL that executes in the context of other users' sessions, including administrators, potentially leading to session hijacking and unauthorized access. The following versions of Johnson Controls Metasys are affected: Metasys 12 vers:all/* (CVE-2026-34491)…
Read more of the source summary
Metasys 13 vers:all/* (CVE-2026-34491) Metasys 14 Metasys 15 CVSS Vendor Equipment Vulnerabilities v3 8 Johnson Controls Inc Johnson Controls Metasys Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') Background Critical Infrastructure Sectors: Critical Manufacturing, Commercial Facilities, Government Services and Facilities, Transportation Systems, Energy Countries/Areas Deployed: Worldwide Company Headquarters Location: Ireland Vulnerabilities Expand All + CVE-2026-34491 A low-privilege user can inject a malicious XSS payload into the Metasys UI via a crafted URL. The payload persists across logins and executes in the browser context of other users, including administrators. View CVE Details Affected Products Johnson Controls Metasys…
View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to tamper with serialized data, potentially resulting in code execution during deserialization. The following versions of AVEVA Enterprise SCADA are affected: Enterprise SCADA 2025 (CVE-2025-7639) Enterprise SCADA >=2024|<=2024_SP1_P01 (CVE-2025-7639) Enterprise SCADA >=2023|<=2023_SP1 (CVE-2025-7639) Enterprise SCADA…
Read more of the source summary
>=2022|<=2022_SP2_P2 (CVE-2025-7639) Enterprise SCADA <=2021_SP2_P5 (CVE-2025-7639) Enterprise SCADA HMI 2024|2024|R2 (CVE-2025-7639) Enterprise SCADA HMI <=2023_P1 (CVE-2025-7639) CVSS Vendor Equipment Vulnerabilities v3 7.1 AVEVA AVEVA Enterprise SCADA Deserialization of Untrusted Data Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: United Kingdom Vulnerabilities Expand All + CVE-2025-7639 The vulnerability, if exploited, could allow an authenticated miscreant with "DNA Authority - Operator" privilege to tamper with serialized data, potentially resulting in code execution during deserialization under the privilege of Enterprise SCADA security group "DNA Apps". View CVE Details Affected Products…
View CSAF Summary Successful exploitation of this vulnerability may allow an attacker to inject and execute arbitrary OS commands with root privileges. The following versions of Haiwell IoT Cloud HMI Gateway are affected: Haiwell IoT Cloud HMI Gateway 3.40.1.12 (CVE-2026-19188) CVSS Vendor Equipment Vulnerabilities v3 10 Haiwell Haiwell IoT Cloud HMI Gateway Improper Neutralization of Special Elements used in an OS…
Read more of the source summary
Command ('OS Command Injection') Background Critical Infrastructure Sectors: Energy, Critical Manufacturing, Water and Wastewater Countries/Areas Deployed: Worldwide Company Headquarters Location: China Vulnerabilities Expand All + CVE-2026-19188 A critical OS command injection vulnerability has been identified in the Haiwell IoT Cloud HMI Gateway product. The vulnerability exists in the Net Check feature accessible via the /setting endpoint. The cmdPing Socket.io event fails to properly sanitize user-supplied input before passing it to the underlying operating system, allowing an attacker to inject and execute arbitrary OS commands with root privileges View CVE Details Affected Products Haiwell IoT Cloud HMI Gateway Vendor: Haiwell Product Version: Haiwell Haiwell IoT…
View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to decrypt sensitive data, bypass authentication controls, gaining unauthorized access to read arbitrary files on the system, or gain unauthorized access to protected system resources. The following versions of Johnson Controls Inc. Airwall are affected: Airwall <=4.0.4 (CVE-2026-64887, CVE-2026-34492) CVSS Vendor Equipment…
Read more of the source summary
Vulnerabilities v3 6.8 Johnson Controls Inc. Johnson Controls Inc. Airwall Use of Hard-coded Cryptographic Key, External Control of File Name or Path Background Critical Infrastructure Sectors: Critical Manufacturing, Commercial Facilities, Government Services and Facilities, Transportation Systems, Energy Countries/Areas Deployed: Worldwide Company Headquarters Location: Ireland Vulnerabilities Expand All + CVE-2026-64887 A hardcoded password or cryptographic key was identified in the Airwall application. A hardcoded credential leads to a significant authentication failure that can be difficult for system or application administrators to detect. Once discovered, it is difficult to remediate without manually modifying or patching the software. The hardcoded key is…
View CSAF Summary A vulnerability in Desigo DXR and PXC controllers has been identified that could allow an attacker to cause denial of service conditions by sending malformed BACnet packets. Recovery requires a device reset or reboot to restore normal functionality. Siemens has released new versions for the affected products and recommends to update to the latest versions. The following versions of Siemens Desigo…
Read more of the source summary
DXR and PXC Controllers are affected: Desigo DXR2 vers:intdot/<01.21.233.16-7862 (CVE-2026-59693) Desigo PXC3 vers:intdot/<01.21.233.16-7862 (CVE-2026-59693) Desigo PXC4 vers:intdot/<02.21.194.36-2715 (CVE-2026-59693) Desigo PXC5.E003 vers:intdot/<02.21.194.36-2715 (CVE-2026-59693) Desigo PXC5.E24 vers:intdot/<02.21.194.36-2715 (CVE-2026-59693) Desigo PXC7 vers:intdot/<02.21.194.36-2715 (CVE-2026-59693) CVSS Vendor Equipment Vulnerabilities v3 4.3 Siemens Siemens Desigo DXR and PXC Controllers Improper Check for Unusual or Exceptional Conditions Background Critical Infrastructure Sectors: Commercial Facilities, Critical Manufacturing, Energy, Healthcare and Public Health, Transportation Systems Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany…
View CSAF Summary Siemens License Server is affected by multiple vulnerabilities which could allow an attacker to elevate its privileges and read arbitrary files on the system. Siemens has released a new version for Siemens License Server (SLS) and recommends to update to the latest version. The following versions of Siemens License Server (SLS) are affected: Siemens License Server (SLS) vers:intdot/<5.1,…
Read more of the source summary
vers:intdot/<5.3 (CVE-2026-69108, CVE-2026-69109) CVSS Vendor Equipment Vulnerabilities v3 7.5 Siemens Siemens License Server (SLS) Incorrect Permission Assignment for Critical Resource, Path Traversal: '.../...//' Background Critical Infrastructure Sectors: Information Technology Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities Expand All + CVE-2026-69108 The affected application is vulnerable to a local privilege escalation due to an insecure sudoers policy. This could allow an attacker to execute arbitrary commands and plant malicious files as root, leading to full system compromise. View CVE Details Affected Products Siemens License Server (SLS) Vendor: Siemens Product Version: Siemens License Server (SLS) < V5.1 Product Status:…
BioThreat brings together reports from the listed public sources. Open the linked title to read the publisher’s original report and any later corrections. Third-party reports retain their own rights and licenses.
A source date is the date the publisher issued or updated a report. A snapshot date is the day BioThreat collected a copy of the feed. The same report can appear in multiple snapshots, and some days have no saved copy.
Open a feed or saved snapshot for original links and machine-readable JSON, where available. Use MERIDIAN to compare reporting across sources and dates.