CISA Adds Two Known Exploited Vulnerabilities to Catalog

CISA has added two new vulnerabilities to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-67277 MikroTik RouterOS Missing Authentication for Critical Function Vulnerability CVE-2026-86060 MikroTik RouterOS Improper Neutralization of Argument Delimiters in a Command Vulnerability These types of vulnerabilities are a frequent attack vector for malicious cyber…
Read more of the source summary
actors and pose significant risks to the federal enterprise. Binding Operational Directive (BOD) 26-04: Prioritizing Security Updates Based on Risk establishes vulnerability management requirements for Federal Civilian Executive Branch (FCEB) agencies. BOD 26-04 reinforces the importance of the KEV Catalog and requires federal agencies to prioritize rapid remediation of high-risk vulnerabilities, specifically those identified by Common Vulnerabilities and Exposures (CVEs) listed in CISA’s KEV Catalog on publicly exposed assets that grant total control of the asset post-exploitation, while deferring action for lower-risk vulnerabilities. BOD 26-04 further establishes basic expectations for when agencies must check whether threat actors compromised the system before the patch…
Source published · CISA Cybersecurity Advisory

Orthanc DICOM Server

View CSAF Summary Successful exploitation of this vulnerability could allow an authenticated remote attacker to write past the end of a heap allocation when Orthanc decodes an attacker-supplied PNG or JPEG image, resulting in a crash of the Orthanc process and a denial-of-service condition. The following versions of Orthanc DICOM Server are affected: Orthanc DICOM Server <1.13.0. (CVE-2026-87020) CVSS Vendor…
Read more of the source summary
Equipment Vulnerabilities v3 8.1 Orthanc Orthanc DICOM Server Integer Overflow or Wraparound Background Critical Infrastructure Sectors: Healthcare and Public Health Countries/Areas Deployed: Worldwide Company Headquarters Location: Belgium Vulnerabilities Expand All + CVE-2026-87020 An integer overflow in a specified pitch and buffer-size computation leads to a heap out-of-bounds write when Orthanc decodes an attacker-supplied PNG. View CVE Details Affected Products Orthanc DICOM Server Vendor: Orthanc Product Version: Orthanc DICOM Server: <1.13.0. Product Status: known_affected Remediations Mitigation Orthanc recommends users update to v1.13.0. https://orthanc.uclouvain.be/downloads/index.html Relevant CWE: CWE-190 Integer Overflow or Wraparound Metrics CVSS Version Base…
Source published · CISA Cybersecurity Advisory

AVEVA Pipeline Integrity Monitor

View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to disclose information, brute-force hashes, or run arbitrary code in a browser session. The following versions of AVEVA Pipeline Integrity Monitor are affected: AVEVA Pipeline Integrity Monitor <=2025_SP1_P1_build_7.1.9580.8513 (CVE-2026-81821, CVE-2026-81822, CVE-2026-81823, CVE-2026-81824) CVSS Vendor Equipment…
Read more of the source summary
Vulnerabilities v3 8.4 AVEVA AVEVA Pipeline Integrity Monitor Use of Hard-coded Cryptographic Key, Use of a Broken or Risky Cryptographic Algorithm, Missing Authorization, Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: United Kingdom Vulnerabilities Expand All + CVE-2026-81821 The vulnerability, if exploited, could allow a miscreant with read access to PIMBoards project files to decrypt and view sensitive information. View CVE Details Affected Products AVEVA Pipeline Integrity Monitor Vendor: AVEVA Product Version: AVEVA Pipeline Integrity Monitor: <=2025_SP1_P1_build_7.1.9580.8513 Product Status: known_affected…
Source published · CISA Cybersecurity Advisory

ST Engineering iDirect iQ-Series Terminals (Update A)

View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to gain unauthorized access to device information or cause a denial-of-service condition. The following versions of ST Engineering iDirect iQ-Series Terminals (Update A) are affected: Evolution iQ‑Series terminals <=4.5.2.1 (CVE-2026-38059, CVE-2026-38057, CVE-2026-38056, CVE-2026-38058) 3315‑Series terminals <=4.5.2.1…
Read more of the source summary
(CVE-2026-38059, CVE-2026-38057, CVE-2026-38056, CVE-2026-38058) 9‑Series terminals <=4.5.2.1 (CVE-2026-38059, CVE-2026-38057, CVE-2026-38056, CVE-2026-38058) CVSS Vendor Equipment Vulnerabilities v3 8.8 ST Engineering iDirect ST Engineering iDirect iQ-Series Terminals Missing Authentication for Critical Function, Cross-Site Request Forgery (CSRF), Missing Authorization, Exposure of Sensitive System Information to an Unauthorized Control Sphere Background Critical Infrastructure Sectors: Communications, Defense Industrial Base, Energy, Government Services and Facilities, Transportation Systems Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2026-38059 The iDirect iQ200 exposes the /api/identity and /api/ REST…
Source published · CISA Cybersecurity Advisory

NextGen Healthcare Mirth Connect

View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to exfiltrate date or cause a denial-of-service condition. The following versions of NextGen Healthcare Mirth Connect are affected: Mirth Connect <=v4.7.1 (CVE-2026-82583, CVE-2026-78224, CVE-2026-82578) CVSS Vendor Equipment Vulnerabilities v3 8.3 NextGen Healthcare NextGen Healthcare Mirth Connect Improper Neutralization of…
Read more of the source summary
Special Elements used in an SQL Command ('SQL Injection'), Improper Restriction of XML External Entity Reference Background Critical Infrastructure Sectors: Healthcare and Public Health Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2026-82583 NextGen Connect (Mirth Connect) versions 4.7.1 and earlier allow an authenticated user to execute arbitrary SQL through a Database Connector API, which could result in disclosure of stored credentials for connected systems, arbitrary file write, and a denial-of-service condition. View CVE Details Affected Products NextGen Healthcare Mirth Connect Vendor: NextGen Healthcare Product Version: NextGen Healthcare Mirth Connect: <=v4.7.1 Product Status: known_affected…
Source published · CISA Cybersecurity Advisory

CISA Adds Four Known Exploited Vulnerabilities to Catalog

CISA has added four new vulnerabilities to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2025-25249 Fortinet Multiple Products Heap-based Buffer Overflow Vulnerability CVE-2026-19490 Citrix NetScaler Authentication Bypass Using an Alternate Path or Channel Vulnerability CVE-2026-87491 Google Chromium V8 Out of Bounds Write Vulnerability CVE-2026-20079 Cisco Firewall…
Read more of the source summary
Management Center Authentication Bypass Using an Alternate Path or Channel Vulnerability These types of vulnerabilities are a frequent attack vector for malicious cyber actors and pose significant risks to the federal enterprise. Binding Operational Directive (BOD) 26-04: Prioritizing Security Updates Based on Risk establishes vulnerability management requirements for Federal Civilian Executive Branch (FCEB) agencies. BOD 26-04 reinforces the importance of the KEV Catalog and requires federal agencies to prioritize rapid remediation of high-risk vulnerabilities, specifically those identified by Common Vulnerabilities and Exposures (CVEs) listed in CISA’s KEV Catalog on publicly exposed assets that grant total control of the asset post-exploitation, while deferring…
Source published · CISA Cybersecurity Advisory

China-Based Artificial Intelligence Companies Conducting Industrial-Scale Distillation Campaigns Against U.S. AI Companies

Executive summary China-based artificial intelligence (AI) companies are conducting systematic extraction of proprietary functionalities and capabilities of U.S. AI companies’ models through industrial-scale knowledge distillation campaigns that form the core—not merely a supplement—of their AI development strategy. While “distillation” is recognized as a legitimate and useful technique in AI research, China-based…
Read more of the source summary
AI companies are engaging in aggressive, malicious, and targeted distillation activities at an industrial scale that extract restricted proprietary functionalities and capabilities of U.S. frontier AI models. The National Security Agency (NSA), Cybersecurity and Infrastructure Security Agency (CISA), and Federal Bureau of Investigation (FBI) (hereafter referred to as the authoring agencies) are releasing this joint Cybersecurity Advisory to alert organizations about these malicious activities and techniques and recommend mitigations to reduce their potential impact. Likely with Chinese government awareness, DeepSeek, Moonshot AI, Alibaba, MiniMax, StepFun, and Z.AI extracted billions of tokens across millions of exchanges/requests from U.S. frontier AI models, including…
Source published · CISA Cybersecurity Advisory

CareCam Pro IP Cameras

View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to take full control of the device. The following versions of CareCam Pro IP Cameras are affected: ANJIA AJL33PC0801 Firmware linux_linux_202008261138_svn13796_/_Bootloader_U-Boot_2010.06_compiled_2020-08-26 (CVE-2026-85083) CVSS Vendor Equipment Vulnerabilities v3 6.8 CareCam CareCam Pro IP Cameras Use of Hard-coded Credentials…
Read more of the source summary
Background Critical Infrastructure Sectors: Commercial Facilities Countries/Areas Deployed: Worldwide Company Headquarters Location: China Vulnerabilities Expand All + CVE-2026-85083 The ANJIA AJL33PC0801 IP camera uses a hard-coded credential for bootloader authentication. An attacker with physical access to the device may leverage this weakness to gain privileged bootloader access, allowing unauthorized modification of firmware and system configuration and potentially resulting in complete device compromise. View CVE Details Affected Products CareCam Pro IP Cameras Vendor: CareCam Product Version: CareCam ANJIA AJL33PC0801 Firmware: linux_linux_202008261138_svn13796_/_Bootloader_U-Boot_2010.06_compiled_2020-08-26 Product Status: known_affected Remediations Mitigation…
Source published · CISA Cybersecurity Advisory

CISA Adds Four Known Exploited Vulnerabilities to Catalog

CISA has added four new vulnerabilities to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-75650 Adobe Commerce and Magento Improper Neutralization of Special Elements Used in a Template Engine Vulnerability CVE-2026-81963 Microsoft Windows Link Following Vulnerability CVE-2026-85880 Microsoft Windows Heap-Based Buffer Overflow Vulnerability CVE-2026-86218 N-able…
Read more of the source summary
N-central Static Code Injection Vulnerability These types of vulnerabilities are a frequent attack vector for malicious cyber actors and pose significant risks to the federal enterprise. Binding Operational Directive (BOD) 26-04: Prioritizing Security Updates Based on Risk establishes vulnerability management requirements for Federal Civilian Executive Branch (FCEB) agencies. BOD 26-04 reinforces the importance of the KEV Catalog and requires federal agencies to prioritize rapid remediation of high-risk vulnerabilities, specifically those identified by Common Vulnerabilities and Exposures (CVEs) listed in CISA’s KEV Catalog on publicly exposed assets that grant total control of the asset post-exploitation, while deferring action for lower-risk vulnerabilities. BOD…
Source published · CISA Cybersecurity Advisory

CISA Adds One Known Exploited Vulnerability to Catalog

CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-85046 Google Chromium V8 Type Confusion Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 26-04: Prioritizing Security Updates Based on Risk…
Read more of the source summary
establishes vulnerability management requirements for Federal Civilian Executive Branch (FCEB) agencies. BOD 26-04 reinforces the importance of the KEV Catalog and requires federal agencies to prioritize rapid remediation of high-risk vulnerabilities, specifically those identified by Common Vulnerabilities and Exposures (CVEs) listed in CISA’s KEV Catalog on publicly exposed assets that grant total control of the asset post-exploitation, while deferring action for lower-risk vulnerabilities. BOD 26-04 further establishes basic expectations for when agencies must check whether threat actors compromised the system before the patch was applied. While BOD 26-04 applies only to FCEB agencies, CISA encourages all organizations to adopt risk-based vulnerability management and…
Source published · CISA Cybersecurity Advisory

Preparing for the Post-Quantum Era: A Call to Action

CISA and the Group of Seven (G7) Cyber Security Working Group released Preparing for the Post-Quantum Era: A Call to Action highlighting the urgent need for organizations and governments to begin transitioning to post-quantum cryptography (PQC) to protect sensitive data, authentication systems, and critical assets from emerging quantum computing threats. The G7 Cyber Security Working Group’s call to action outlines…
Read more of the source summary
five priorities for a successful transition to PQC: Raising awareness of quantum risks and the importance of PQC; Developing national strategies that support PQC adoption and integration; Advancing research and development for quantum-safe technologies; Fostering public-private partnerships to share expertise and resources; and Integrating PQC into cybersecurity requirements and procurement processes. Please share your thoughts! We welcome your feedback. CISA PRODUCT SURVEY
Source published · CISA Cybersecurity Advisory

IXON VPN Client

View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to perform remote code execution on the computer running the client with elevated privileges. The following versions of IXON VPN Client are affected: VPN Client <1.4.7 (CVE-2026-75925) CVSS Vendor Equipment Vulnerabilities v3 9.6 IXON IXON VPN Client Improper Neutralization of CRLF Sequences ('CRLF Injection') Background Critical…
Read more of the source summary
Infrastructure Sectors: Commercial Facilities, Critical Manufacturing, Energy, Information Technology, Water and Wastewater Countries/Areas Deployed: Worldwide Company Headquarters Location: Netherlands Vulnerabilities Expand All + CVE-2026-75925 Improper Neutralization of CRLF Sequences (CWE-93) in IXON VPN Client before version 1.4.7 allows an attacker to execute commands as root or SYSTEM. Configuration values accepted by the local service are written to a file later consumed by a privileged subprocess, without line-ending sequences being neutralised, which allows additional directives to be introduced into that file. The configuration interface accepts changes without authenticating or verifying the origin of the requester (CWE-306, contributing). The injected…
Source published · CISA Cybersecurity Advisory

Inductive Automation Ignition

View CSAF Summary Successful exploitation of this vulnerability could allow any authenticated user to create projects. The following versions of Inductive Automation Ignition are affected: Ignition <=8.1.53 (CVE-2026-77393) CVSS Vendor Equipment Vulnerabilities v3 8.8 Inductive Automation Inductive Automation Ignition Incorrect Default Permissions Background Critical Infrastructure Sectors: Critical Manufacturing,…
Read more of the source summary
Energy, Information Technology Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2026-77393 In Ignition 8.1.53 and earlier, the Gateway "Create Project Role(s)" setting shipped blank, which permitted any authenticated user to create projects (if they can execute gateway scripts). Ignition 8.1.54 restricts project creation to Designer sessions and no longer relies on this setting. The 8.3 series is not affected. View CVE Details Affected Products Inductive Automation Ignition Vendor: Inductive Automation Product Version: Inductive Automation Ignition: <=8.1.53 Product Status: known_affected Remediations Mitigation Inductive Automation has determined that this issue is a default-value configuration, not a flaw…
Source published · CISA Cybersecurity Advisory

Rockwell Automation ArmorStart LT

View CSAF Summary Successful exploitation of these vulnerabilities could result in a loss of webserver availability or allow an attacker to inject malicious scripts that will be executed when other users access the affected page. The following versions of Rockwell Automation ArmorStart LT are affected: ArmorStart LT <=v2.001 (CVE-2026-19471, CVE-2026-19472) CVSS Vendor Equipment Vulnerabilities v3 7.5 Rockwell…
Read more of the source summary
Automation Rockwell Automation ArmorStart LT Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting'), Allocation of Resources Without Limits or Throttling Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2026-19471 Multiple stored cross-site scripting security issues exist within ArmorStart LT. Stored XSS occurs when user input is not properly sanitized and is stored on the server, allowing an attacker to inject malicious scripts that will be executed when other users access the affected page. View CVE Details Affected Products Rockwell Automation ArmorStart LT Vendor: Rockwell Automation Product Version: Rockwell…
Source published · CISA Cybersecurity Advisory

Schneider Electric Easergy, EcoStruxture, PowerLogic, and Saitel Products (Update A)

View CSAF Summary Schneider Electric is aware of a vulnerability in the following products: The Easergy C5 is a scalable and interoperable bay controller, protection and merging unit for large and critical infrastructure electrical distribution systems. The Easergy MiCOM P30 is a family of multifunction protection and control relays designed for medium, high and extra high voltage electrical networks. The Easergy…
Read more of the source summary
MiCOM P40 is a protection relay series for Medium Voltage, High Voltage and Extra High Voltage protection. The Easergy MiCOM C264 is a modular and compact substation or bay controller, smart RTU and MV one box solution The EcoStruxure Power Automation System Gateway (EPAS=GTW) is a scalable, interoperable, and rugged communication gateway that helps to remotely monitor and operate electrical processes The EcoStruxure Power Automation System User Interface (EPAS-UI) product is an HMI SCADA designed for electrical networks and substations operations. The EcoStruxure Power Automation System Intelligent Power Management System and Fast Load Shedding (iPMFLS) is a range of solutions designed to overcome size and performances constraints. The EcoStruxure Power Operation (EPO)…
Source published · CISA Cybersecurity Advisory

OPCFoundation OPC UA LocalDiscoveryServer (LDS)

View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to take control of a high-privilege terminal during installation and run arbitrary commands. The following versions of OPCFoundation OPC UA LocalDiscoveryServer (LDS) are affected: UA-LDS-Installers <1.04.420 (CVE-2026-77477) CVSS Vendor Equipment Vulnerabilities v3 4.6 OPCFoundation OPCFoundation OPC UA LocalDiscoveryServer…
Read more of the source summary
(LDS) Execution with Unnecessary Privileges Background Critical Infrastructure Sectors: Chemical, Energy, Food and Agriculture, Water and Wastewater, Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2026-77477 An attacker can intercept a high-privilege console window launched during installation of the LDS. The attacker must be able to launch an installer with elevated privileges and have access to the keyboard and display while the installation is taking place. View CVE Details Affected Products OPCFoundation OPC UA LocalDiscoveryServer (LDS) Vendor: OPCFoundation Product Version: OPCFoundation UA-LDS-Installers: <1.04.420 Product Status: known_affected Remediations Mitigation…
Source published · CISA Cybersecurity Advisory

Pyramid Solutions NetStaX EtherNet/IP Stack

View CSAF Summary Successful exploitation of this vulnerability could result in memory corruption, a device crash, or a potential remote attack vector without the originating device receiving a CIP error indicating that the request could not be processed. The following versions of Pyramid Solutions NetStaX EtherNet/IP Stack are affected: EtherNet/IP Adapter DLL Kit (EIPA) EtherNet/IP Adapter DLL Kit with CIP…
Read more of the source summary
Security (EIPA-SECURE) EtherNet/IP Adapter Development Kit (EADK) EtherNet/IP Adapter Development Kit with CIP Security (EADK-SECURE) EtherNet/IP Scanner DLL Kit (EIPS) EtherNet/IP Scanner DLL Kit with CIP Security (EIPS-SECURE) EtherNet/IP Scanner Development Kit (ESDK) EtherNet/IP Scanner Development Kit with CIP Security (ESDK-SECURE) CVSS Vendor Equipment Vulnerabilities v3 9.8 Pyramid Solutions Pyramid Solutions NetStaX EtherNet/IP Stack Stack-based Buffer Overflow Background Critical Infrastructure Sectors: Critical Manufacturing, Energy, Water and Wastewater, Chemical Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2026-78012 An issue in the NetStaX EtherNet/IP Stack prior to v5.6.1 could allow a large…
Source published · CISA Cybersecurity Advisory

Rockwell Automation ControlFLASH

View CSAF Summary Successful exploitation of this vulnerability could give an attacker the ability to run any commands or code of the attacker's choice on a target machine at the logged-in user's permission level. The following versions of Rockwell Automation ControlFLASH are affected: ControlFLASH <=V15.07 (CVE-2026-12663) CVSS Vendor Equipment Vulnerabilities v3 7.3 Rockwell Automation Rockwell Automation…
Read more of the source summary
ControlFLASH Missing Authentication for Critical Function Background Critical Infrastructure Sectors: Critical Manufacturing, Energy, Water and Wastewater Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2026-12663 A security issue exists within ControlFLASH, where the installer grants write permissions to the "Everyone" group on a product installation directory. This could allow arbitrary code execution, resulting in an attacker being given the ability to run any commands or code of the attacker's choice on a target machine at the logged-in user's permission level. View CVE Details Affected Products Rockwell Automation ControlFLASH Vendor: Rockwell Automation Product Version: Rockwell Automation ControlFLASH:…
Source published · CISA Cybersecurity Advisory

Rockwell Automation 1756-ENBT Module

View CSAF Summary Successful exploitation of this vulnerability could crash the module. The device requires a restart to recover. The following versions of Rockwell Automation 1756-ENBT Module are affected: 1756-ENBT module vers:all/* (CVE-2025-10478) CVSS Vendor Equipment Vulnerabilities v3 7.5 Rockwell Automation Rockwell Automation 1756-ENBT Module Improper Check for Unusual or Exceptional Conditions Background…
Read more of the source summary
Critical Infrastructure Sectors: Critical Manufacturing, Food and Agriculture, Transportation Systems, Water and Wastewater Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2025-10478 A denial-of-service security issue exists in the Rockwell Automation 1756-ENBT module which is a ControlLogix EtherNet/IP bridge that enables communication between Logix 5000 controllers and Ethernet devices. An attacker could exploit this vulnerability by sending a crafted CIP packet, causing the module to crash. The device requires a restart to recover. View CVE Details Affected Products Rockwell Automation 1756-ENBT Module Vendor: Rockwell Automation Product Version: Rockwell Automation 1756-ENBT module: vers:all/* Product…
Source published · CISA Cybersecurity Advisory

Tycon Systems TPDIN-Monitor-WEB2 (Update A)

View CSAF Summary Successful exploitation of these vulnerabilities could result in an attacker accessing sensitive credentials, disrupting connected infrastructure, or manipulating physical equipment, which could present a physical safety risk. The following versions of Tycon Systems TPDIN-Monitor-WEB2 (Update A) are affected: TPDIN-Monitor-WEB2 <2.4.5 (CVE-2026-61884, CVE-2026-55985) CVSS Vendor Equipment…
Read more of the source summary
Vulnerabilities v3 9.8 Tycon Systems Tycon Systems TPDIN-Monitor-WEB2 Missing Authentication for Critical Function, Cleartext Storage of Sensitive Information Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2026-61884 The device ships without HTTP credentials configured, intended for an installer to set them on first use. On firmware 2.4.4 and earlier, a unit left in this unconfigured state serves the web management interface without requiring any login. An attacker with network access to such a unit can reach full device controls, including power relay management, device reboot, remote access service configuration, and network settings, which…
Browse saved snapshots

How to read the archive

Who published the report?

BioThreat brings together reports from the listed public sources. Open the linked title to read the publisher’s original report and any later corrections. Third-party reports retain their own rights and licenses.

Read the source attribution policy

What does each date mean?

A source date is the date the publisher issued or updated a report. A snapshot date is the day BioThreat collected a copy of the feed. The same report can appear in multiple snapshots, and some days have no saved copy.

Browse current public feeds

How can I use the records?

Open a feed or saved snapshot for original links and machine-readable JSON, where available. Use MERIDIAN to compare reporting across sources and dates.

Explore reports in MERIDIAN

Use the Briefing Builder to combine source-linked records with your own analysis and download a report. See a worked food recall briefing.

Build a MERIDIAN briefing