View CSAF Summary Schneider Electric is aware of multiple vulnerabilities in its NetBotz 5 – 750/755 products.The NetBotz 5 – 750/755 products are security and environmental monitors providing temperature, humidity, leak, smoke, vibration, door contact, and video monitoring capabilities. Failure to apply the remediation provided below may risk arbitrary or remote code execution over the local network, which could…
Read more of the source summary
result in device manipulation and unauthorized data access. The following versions of Schneider Electric NetBotz 5 750/755 are affected: NetBotz 5 750 vers:intdot/<=5.5.2 (CVE-2026-13336, CVE-2026-13337) NetBotz 5 755 vers:intdot/<=5.5.2 (CVE-2026-13336, CVE-2026-13337) CVSS Vendor Equipment Vulnerabilities v3 6.4 Schneider Electric Schneider Electric NetBotz 5 750/755 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection'), SQL Injection: Hibernate Background Critical Infrastructure Sectors: Commercial Facilities, Critical Manufacturing, Information Technology Countries/Areas Deployed: Worldwide Company Headquarters Location: France Vulnerabilities Expand All + CVE-2026-13336 CWE-78: Improper Neutralization of Special Elements used in…
View CSAF Summary Schneider Electric is aware of a vulnerability in its Modicon M340 https://www.se.com/ww/en/product-range/1468-modicon-m340-pac/, BMXNOR0200H https://www.se.com/us/en/product/BMXNOR0200H/communication-module-modicon-m340-iec-608705101-104-dnp3-for-severe-environments/: Modicon M340 X80 Ethernet Communication Modules, BMXNGD0100…
Read more of the source summary
https://www.se.com/us/en/product/BMXNGD0100/communication-module-modicon-m580-global-data-service/: M580 Global Data module, BMXNOC0401 https://www.se.com/us/en/product/BMXNOC0401/network-module-modicon-m340-ethernet-ip-and-modbus-tcp-4-x-rj45/?pageType=product&sourceId=BMXNOC0401: Modicon M340 X80 Ethernet Communication modules, BMXNOE0100 https://www.se.com/ww/en/product/BMXNOE0100/network-module-modicon-m340-modbus-tcp-1-x-rj45-flash-memory-card/?pageType=product&sourceId=BMXNOE0100: Modbus/TCP Ethernet Modicon M340 module, BMXNOE0110 https://www.se.com/ww/en/product/BMXNOE0110/ethernet-tcp-ip-network-module-modicon-m340-automation-platform-flash-memory-card-internal-ram-16-mb-1-x-rj45-10-100/: Modbus/TCP Ethernet Modicon M340 FactoryCast module product(s). Failure to apply the fix provided below may risk Denial Of Service attack, which…
CISA has added two new vulnerabilities to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-76460 Cisco Identity Services Engine Incorrect Use of Privileged APIs Vulnerability CVE-2026-87886 Acronis Backup Incorrect Default Permissions Vulnerability These types of vulnerabilities are a frequent attack vector for malicious cyber actors and pose significant risks to…
Read more of the source summary
the federal enterprise. Binding Operational Directive (BOD) 26-04: Prioritizing Security Updates Based on Risk establishes vulnerability management requirements for Federal Civilian Executive Branch (FCEB) agencies. BOD 26-04 reinforces the importance of the KEV Catalog and requires federal agencies to prioritize rapid remediation of high-risk vulnerabilities, specifically those identified by Common Vulnerabilities and Exposures (CVEs) listed in CISA’s KEV Catalog on publicly exposed assets that grant total control of the asset post-exploitation, while deferring action for lower-risk vulnerabilities. BOD 26-04 further establishes basic expectations for when agencies must check whether threat actors compromised the system before the patch was applied. While BOD 26-04…
CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-58704 Google Pixel Improper Authorization Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 26-04: Prioritizing Security Updates Based on…
Read more of the source summary
Risk establishes vulnerability management requirements for Federal Civilian Executive Branch (FCEB) agencies. BOD 26-04 reinforces the importance of the KEV Catalog and requires federal agencies to prioritize rapid remediation of high-risk vulnerabilities, specifically those identified by Common Vulnerabilities and Exposures (CVEs) listed in CISA’s KEV Catalog on publicly exposed assets that grant total control of the asset post-exploitation, while deferring action for lower-risk vulnerabilities. BOD 26-04 further establishes basic expectations for when agencies must check whether threat actors compromised the system before the patch was applied. While BOD 26-04 applies only to FCEB agencies, CISA encourages all organizations to adopt risk-based vulnerability management…
CISA developed this guidance to help defensive teams at varying levels of cybersecurity maturity plan and implement cyber decoy strategies that strengthen their detection and response capabilities. Many organizations struggle to detect adversaries who use legitimate credentials, native tools, and living off the land (LOTL) techniques to conduct discovery, move laterally, and access data. Cyber decoys are assets that…
Read more of the source summary
appear to be legitimate systems, accounts, or data, but are designed to distract adversaries, detect their presence, or facilitate collection of cyber threat intelligence (CTI). As organizations adopt Zero Trust models, they should assume that a malicious threat actor may gain some level of access to their environment and plan accordingly. Cyber decoys complement Zero Trust by: Supporting continuous monitoring and verification, Creating high-fidelity alerts for suspicious activity, Reducing alert fatigue, and Helping defenders detect post-compromise activity, including adversary LOTL techniques. This guidance introduces decoy concepts—including tripwires, breadcrumbs, and honeytokens—and uses the MITRE Engage™ and MITRE ATT&CK® frameworks to provide practical,…
View CSAF Summary Successful exploitation of these vulnerabilities could grant full administrative control of the device, allowing an attacker to view live and recorded surveillance, alter device configurations, and use the device as a network pivot point. The following versions of Digital Watchdog VMAX DVR and NVR Product Lineups are affected: VMAX A1 G4 DVRs vers:all/* (CVE-2026-68953, CVE-2026-66890,…
Read more of the source summary
CVE-2026-68070, CVE-2026-68950, CVE-2026-66887, CVE-2026-66372) VMAX IP G4 NVRs vers:all/* (CVE-2026-68953, CVE-2026-66890, CVE-2026-68070, CVE-2026-68950, CVE-2026-66887, CVE-2026-66372) VMAX A1 PLUS vers:all/* (CVE-2026-68953, CVE-2026-66890, CVE-2026-68070, CVE-2026-68950, CVE-2026-66887, CVE-2026-66372) VA1G4 Recorder vers:all/* (CVE-2026-68953, CVE-2026-66890, CVE-2026-68070, CVE-2026-68950, CVE-2026-66887, CVE-2026-66372) VG4 Recorder vers:all/* (CVE-2026-68953, CVE-2026-66890, CVE-2026-68070, CVE-2026-68950, CVE-2026-66887, CVE-2026-66372) CVSS Vendor Equipment Vulnerabilities v3 9.6 Digital Watchdog Digital Watchdog VMAX DVR and NVR Product Lineups Missing Authentication for Critical Function, Use of Hard-coded Credentials, Missing Authorization, Predictable Seed in…
View CSAF Summary Schneider Electric is aware of a vulnerability in its SCADAPack x70 products. The SCADAPack 47x, SCADAPack 47xi, SCADAPack 47xd, SCADAPack 470R and SCADAPack 57x products are Remote Terminal Units that provide communication capabilities for remote monitoring and control. Failure to apply the mitigations provided below may increase the risk of unauthorized access to RTU configuration through the…
Read more of the source summary
Secure Lock functionality, potentially resulting in a loss of confidentiality. The following versions of Schneider Electric SCADAPack x70 Products are affected: SCADAPack 47x vers:all/* (CVE-2026-81861) SCADAPack 47xi vers:all/* (CVE-2026-81861) SCADAPack 47xd vers:all/* (CVE-2026-81861) SCADAPack 470R vers:all/* (CVE-2026-81861) SCADAPack 57x vers:all/* (CVE-2026-81861) SCADAPack 3xx vers:all/* (CVE-2026-81861) SCADAPack 32 vers:all/* (CVE-2026-81861) CVSS Vendor Equipment Vulnerabilities v3 6.5 Schneider Electric Schneider Electric SCADAPack x70 Products Insufficiently Protected Credentials Background Critical Infrastructure Sectors: Critical Manufacturing, Energy Countries/Areas Deployed: Worldwide Company Headquarters Location: France Vulnerabilities Expand All +…
View CSAF Summary Siemens Reyrolle 7SR5 Before V2.70 is affected by multiple vulnerabilities. Siemens has released a new version for Reyrolle 7SR5 and recommends to update to the latest version. The following versions of Siemens Reyrolle 7SR5 are affected: Reyrolle 7SR5 vers:intdot/<2.70 (CVE-2024-42384, CVE-2024-42385, CVE-2024-42386, CVE-2024-42391, CVE-2024-42392, CVE-2026-62645, CVE-2026-62646, CVE-2026-62647,…
Read more of the source summary
CVE-2026-62648, CVE-2026-62649, CVE-2026-62650, CVE-2026-62652, CVE-2026-62653, CVE-2026-62654) CVSS Vendor Equipment Vulnerabilities v3 9.8 Siemens Siemens Reyrolle 7SR5 Integer Overflow or Wraparound, Improper Neutralization of Delimiters, Use of Out-of-range Pointer Offset, Missing Authentication for Critical Function, Insufficient Entropy, Improper Input Validation, Out-of-bounds Write, Allocation of Resources Without Limits or Throttling, Authentication Bypass Using an Alternate Path or Channel, Insertion of Sensitive Information Into Debugging Code, Download of Code Without Integrity Check Background Critical Infrastructure Sectors: Energy Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities Expand All + CVE-2024-42384 Integer…
View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to access privileged management functions or send arbitrary SMS messages through the connected GSM modem. The following versions of mySCADA myPRO Manager are affected: mySCADA myPRO Manager <=2.1 (CVE-2026-73807, CVE-2026-82567) CVSS Vendor Equipment Vulnerabilities v3 9.8 mySCADA Technologies mySCADA myPRO Manager Missing…
Read more of the source summary
Authorization, Missing Authentication for Critical Function Background Critical Infrastructure Sectors: Critical Manufacturing, Energy, Food and Agriculture, Transportation Systems, Water and Wastewater Countries/Areas Deployed: Worldwide Company Headquarters Location: Czechia Vulnerabilities Expand All + CVE-2026-73807 The mySCADA myPRO Manager command API does not properly enforce authentication for privileged functions. An unauthenticated attacker with network access to the affected API could exploit this vulnerability to access privileged management functions. View CVE Details Affected Products mySCADA myPRO Manager Vendor: mySCADA Technologies Product Version: mySCADA Technologies mySCADA myPRO Manager: <=2.1 Product Status: known_affected Remediations Mitigation…
View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to deliver an unauthorized update, execute code, or extract credentials to allow the attacker to impersonate a privileged client. The following versions of Wärtsilä FOS-Onboard are affected: FOS-Onboard 5.07.0923.01 (CVE-2026-78225, CVE-2026-81855) CVSS Vendor Equipment Vulnerabilities v3 9.1 Wärtsilä Wärtsilä FOS-Onboard Use…
Read more of the source summary
of Hard-coded Cryptographic Key Background Critical Infrastructure Sectors: Transportation Systems Countries/Areas Deployed: Worldwide Company Headquarters Location: Finland Vulnerabilities Expand All + CVE-2026-78225 A hardcoded cryptographic server key vulnerability exists in the deployer-ng Update Controller component of Wärtsilä FOS-Onboard. View CVE Details Affected Products Wärtsilä FOS-Onboard Vendor: Wärtsilä Product Version: Wärtsilä FOS-Onboard: 5.07.0923.01 Product Status: known_affected Remediations Mitigation Wärtsilä states that the vulnerabilities are not exploitable when the product is installed as recommended, and has developed a security patch. Users are also directed to contact Wärtsilä to obtain and install the patch. To obtain and install the latest…
BioThreat brings together reports from the listed public sources. Open the linked title to read the publisher’s original report and any later corrections. Third-party reports retain their own rights and licenses.
A source date is the date the publisher issued or updated a report. A snapshot date is the day BioThreat collected a copy of the feed. The same report can appear in multiple snapshots, and some days have no saved copy.
Open a feed or saved snapshot for original links and machine-readable JSON, where available. Use MERIDIAN to compare reporting across sources and dates.