Mitsubishi Electric and Mitsubishi Electric Iconics Digital Solutions GENESIS, GENESIS64, ICONICS Suite, Hyper Historian, AnalytiX, MobileHMI, IoTWorX, MC Works64, GENESIS32 and BizViz

View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to execute arbitrary code (CVE-2023-4863), bypass authentication (CVE-2026-16436 and CVE-2026-16437), or perform arbitrary operations (CVE-2026-16438), resulting in information disclosure, tampering with, destruction, or deletion of information, and a denial-of-service (DoS) condition of the system. The following versions of…
Read more of the source summary
Mitsubishi Electric GENESIS, GENESIS64, ICONICS Suite, HyperHistorian, AnalytiX, MobileHMI, IoTWorX, MC Works64, GENESIS32, BizViz, Mitsubishi Electric Iconics Digital Solutions GENESIS, GENESIS64, ICONICS Suite, HyperHistorian, AnalytiX, MobileHMI, IoTWorX, GENESIS32 and BizViz are affected: Mitsubishi Electric and Mitsubishi Electric Iconics Digital Solutions GENESIS64 >=10.97|=10.97|
Source published · CISA Cybersecurity Advisories

CISA Adds Two Known Exploited Vulnerabilities to Catalog

CISA has added two new vulnerabilities to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-48356 Adobe Commerce and Magento Unrestricted Upload of File with Dangerous Type Vulnerability CVE-2026-111497 Google Brotli Unchecked Return Value Vulnerability These types of vulnerabilities are a frequent attack vector for malicious cyber actors and pose significant risks…
Read more of the source summary
to the federal enterprise. Binding Operational Directive (BOD) 26-04: Prioritizing Security Updates Based on Risk establishes vulnerability management requirements for Federal Civilian Executive Branch (FCEB) agencies. BOD 26-04 reinforces the importance of the KEV Catalog and requires federal agencies to prioritize rapid remediation of high-risk vulnerabilities, specifically those identified by Common Vulnerabilities and Exposures (CVEs) listed in CISA’s KEV Catalog on publicly exposed assets that grant total control of the asset post-exploitation, while deferring action for lower-risk vulnerabilities. BOD 26-04 further establishes basic expectations for when agencies must check whether threat actors compromised the system before the patch was applied. While BOD 26-04…
Source published · CISA Cybersecurity Advisories

EPICS Base

View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to cause a denial-of-service condition, corrupt memory, disclose sensitive information, or potentially execute arbitrary code. The following versions of EPICS Base are affected: EPICS Base release
Source published · CISA Cybersecurity Advisories

CISA Adds Two Known Exploited Vulnerabilities to Catalog

CISA has added two new vulnerabilities to its Known Exploited Vulnerabilities (KEV) Catalog and updated the PHP Alert, Critical Vulnerabilities in PHP Require Immediate Patching: CVE-2026-109618 – PHP Memory Corruption Vulnerability CVE-2026-109619 – PHP Stale Internal Request-State Vulnerability These types of vulnerabilities are a frequent attack vector for malicious cyber actors and pose significant risks to the…
Read more of the source summary
federal enterprise. Binding Operational Directive (BOD) 26-04: Prioritizing Security Updates Based on Risk establishes vulnerability management requirements for Federal Civilian Executive Branch (FCEB) agencies. BOD 26-04 reinforces the importance of the KEV Catalog and requires federal agencies to prioritize rapid remediation of high-risk vulnerabilities, specifically those identified by Common Vulnerabilities and Exposures (CVEs) listed in CISA’s KEV Catalog on publicly exposed assets that grant total control of the asset post-exploitation, while deferring action for lower-risk vulnerabilities. BOD 26-04 further establishes basic expectations for when agencies must check whether threat actors compromised the system before the patch was applied. While BOD 26-04 applies…
Source published · CISA Cybersecurity Advisories

CISA Adds One Known Exploited Vulnerability to Catalog

CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-114625 Arista VeloCloud Orchestrator SQL Injection Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 26-04: Prioritizing Security Updates…
Read more of the source summary
Based on Risk establishes vulnerability management requirements for Federal Civilian Executive Branch (FCEB) agencies. BOD 26-04 reinforces the importance of the KEV Catalog and requires federal agencies to prioritize rapid remediation of high-risk vulnerabilities, specifically those identified by Common Vulnerabilities and Exposures (CVEs) listed in CISA’s KEV Catalog on publicly exposed assets that grant total control of the asset post-exploitation, while deferring action for lower-risk vulnerabilities. BOD 26-04 further establishes basic expectations for when agencies must check whether threat actors compromised the system before the patch was applied. While BOD 26-04 applies only to FCEB agencies, CISA encourages all organizations to adopt risk-based vulnerability…
Source published · CISA Cybersecurity Advisories

CISA Adds One Known Exploited Vulnerability to Catalog

CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-110447 Collabora Online – Built-in CODE Server OS Command Injection Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 26-04: Prioritizing…
Read more of the source summary
Security Updates Based on Risk establishes vulnerability management requirements for Federal Civilian Executive Branch (FCEB) agencies. BOD 26-04 reinforces the importance of the KEV Catalog and requires federal agencies to prioritize rapid remediation of high-risk vulnerabilities, specifically those identified by Common Vulnerabilities and Exposures (CVEs) listed in CISA’s KEV Catalog on publicly exposed assets that grant total control of the asset post-exploitation, while deferring action for lower-risk vulnerabilities. BOD 26-04 further establishes basic expectations for when agencies must check whether threat actors compromised the system before the patch was applied. While BOD 26-04 applies only to FCEB agencies, CISA encourages all organizations to adopt risk-based…
Source published · CISA Cybersecurity Advisories

Siemens SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP

View CSAF Summary Multiple vulnerabilities have been identified in the additional GNU/Linux subsystem of the firmware version V3.1.7 for the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP (incl. SIPLUS variant). Siemens is preparing fixes and recommends specific mitigations for products where fixes are not or not yet available. The following versions of Siemens SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP are affected: SIMATIC…
Read more of the source summary
S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AB0) vers:intdot/>=3.1.7 SIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AC0) vers:intdot/>=3.1.7 SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AB0) vers:intdot/>=3.1.7 SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AC0) vers:intdot/>=3.1.7 SIPLUS S7-1500 CPU 1518-4 PN/DP MFP (6AG1518-4AX00-4AC0) vers:intdot/>=3.1.7 CVSS Vendor Equipment v3 10 Siemens SIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AB0) 428 Vulnerabilities Access of Resource Using Incompatible Type ('Type Confusion'), Access of Uninitialized Pointer, Active Debug Code, Buffer Access with Incorrect Length Value, Buffer Copy without Checking Size of Input ('Classic Buffer Overflow'), Buffer Underwrite ('Buffer Underflow'), Concurrent…
Source published · CISA Cybersecurity Advisories

Siemens SIMATIC S7-1500 TM MFP

View CSAF Summary Multiple vulnerabilities have been identified in the additional GNU/Linux subsystem of the SIMATIC S7-1500 TM MFP V1.1.1. Siemens is preparing fixes and recommends specific mitigations for products where fixes are not or not yet available. The following versions of Siemens SIMATIC S7-1500 TM MFP are affected: SIMATIC S7-1500 TM MFP - GNU/Linux subsystem vers:all/* CVSS Vendor Equipment v3 10…
Read more of the source summary
Siemens SIMATIC S7-1500 TM MFP - GNU/Linux subsystem 377 Vulnerabilities Access of Uninitialized Pointer, Buffer Copy without Checking Size of Input ('Classic Buffer Overflow'), Deadlock, Detection of Error Condition Without Action, Double Free, Expired Pointer Dereference, Heap-based Buffer Overflow, Improper Control of Resource Identifiers ('Resource Injection'), Improper Control of a Resource Through its Lifetime, Improper Handling of Length Parameter Inconsistency, Improper Handling of Missing Special Element, Improper Handling of Structural Elements, Improper Input Validation, Improper Locking, Improper Resource Locking, Improper Restriction of Operations within the Bounds of a Memory Buffer, Improper Update of Reference Count, Improper Validation of Array Index,…
Source published · CISA Cybersecurity Advisories

Siemens SIMATIC S7 PLCs Web Server

View CSAF Summary SIMATIC S7-1500 devices contain multiple vulnerabilities in the web server that could allow an attacker to execute malicious code in an authorized user’s browser session and perform PLC operations within the scope of that user’s authorization. Siemens is preparing fixes and recommends specific mitigations for products where fixes are not or not yet available. The following versions of Siemens…
Read more of the source summary
SIMATIC S7 PLCs Web Server are affected: SIMATIC Drive Controller CPU 1504D TF (6ES7615-4DF10-0AB0) vers:all/* (CVE-2026-63350, CVE-2026-63351, CVE-2026-63352, CVE-2026-63353, CVE-2026-63354, CVE-2026-63355, CVE-2026-63356, CVE-2026-63357) SIMATIC Drive Controller CPU 1507D TF (6ES7615-7DF10-0AB0) vers:all/* (CVE-2026-63350, CVE-2026-63351, CVE-2026-63352, CVE-2026-63353, CVE-2026-63354, CVE-2026-63355, CVE-2026-63356, CVE-2026-63357) SIMATIC ET 200SP CPU 1510SP F-1 PN (6ES7510-1SJ01-0AB0) vers:all/* (CVE-2026-63350, CVE-2026-63351, CVE-2026-63352, CVE-2026-63353, CVE-2026-63354, CVE-2026-63355, CVE-2026-63356, CVE-2026-63357) SIMATIC ET 200SP CPU 1510SP F-1 PN (6ES7510-1SK03-0AB0) vers:all/* (CVE-2026-63350, CVE-2026-63351, CVE-2026-63352, CVE-2026-63353, CVE-2026-63354,…
Source published · CISA Cybersecurity Advisories

Siemens Capital Embedded AR Classic

View CSAF Summary The products listed below contain an out-of-bounds read vulnerability that could allow an attacker to cause abnormal product behavior, instability, or denial of service. Siemens has released a new version for Capital Embedded AR Classic R20-11 and recommends updating to the latest version. Siemens is preparing further fix versions and recommends specific countermeasures for products where fixes are…
Read more of the source summary
not, or not yet available. The following versions of Siemens Capital Embedded AR Classic are affected: Capital Embedded AR Classic 431-422 vers:all/* (CVE-2026-89208) Capital Embedded AR Classic R20-11 vers:intdot/
Browse saved snapshots

How to read the archive

Who published the report?

BioThreat brings together reports from the listed public sources. Open the linked title to read the publisher’s original report and any later corrections. Third-party reports retain their own rights and licenses.

Read the source attribution policy

What does each date mean?

A source date is the date the publisher issued or updated a report. A snapshot date is the day BioThreat collected a copy of the feed. The same report can appear in multiple snapshots, and some days have no saved copy.

Browse current public feeds

How can I use the records?

Open a feed or saved snapshot for original links and machine-readable JSON, where available. Use MERIDIAN to compare reporting across sources and dates.

Explore reports in MERIDIAN

Use the Briefing Builder to combine source-linked records with your own analysis and download a report. See a worked food recall briefing.

Build a MERIDIAN briefing