View CSAF Summary The products listed below contain an authentication bypass vulnerability that could allow an on-path attacker to take over the session of a legitimate user and execute arbitrary code with the privileges of the victim user. Siemens is preparing fixes and recommends specific mitigations for products where fixes are not or not yet available. The following versions of Siemens SIMATIC are affected:…
Read more of the source summary
SIMATIC BATCH V9.1 vers:all/* (CVE-2026-58114) SIMATIC Information Server 2020 vers:all/* (CVE-2026-58114) SIMATIC Information Server 2022 vers:all/* (CVE-2026-58114) SIMATIC PCS 7 V9.1 vers:all/* (CVE-2026-58114) SIMATIC Process Historian 2020 vers:all/* (CVE-2026-58114) SIMATIC Process Historian 2022 vers:all/* (CVE-2026-58114) SIMATIC WinCC Runtime Professional V17 vers:all/* (CVE-2026-58114) SIMATIC WinCC Runtime Professional V18 vers:all/* (CVE-2026-58114) SIMATIC WinCC Runtime Professional V19 vers:all/* (CVE-2026-58114) SIMATIC WinCC Runtime Professional V20 vers:all/* (CVE-2026-58114) SIMATIC WinCC Runtime Professional V21 vers:all/* (CVE-2026-58114) SIMATIC WinCC V7.5 vers:all/* (CVE-2026-58114) SIMATIC WinCC V8.0 vers:all/* (CVE-2026-58114) SIMATIC WinCC V8.1…
View CSAF Summary On October 21, 2026, the Node.js project released security updates addressing a critical vulnerability in the Brotli decoder bundled with Node.js, commonly referred to as "Node2Shell" (tracked as CVE-2026-111497). The vulnerability is an out-of-bounds write that could allow a remote attacker to cause memory corruption and potentially execute arbitrary code. This advisory covers the status of impact…
Read more of the source summary
of various Siemens products. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fixes and recommends specific mitigations for products where fixes are not or not yet available. The following versions of Siemens Industrial Automation Software Products are affected: COMOS Walkinside vers:all/* (CVE-2026-111497) gDAP (gPROMS Digital Application Platform) vers:all/* () Project Server Web Administration Tool vers:all/* (CVE-2026-111497) SIMATIC BRAUMAT vers:intdot/>=8.2.0.1|=8.2.0.1|
View CSAF Summary Fortinet has published information on a Double Free vulnerability in FortiOS. This advisory lists the related Siemens Industrial products. Siemens recommends to update Fortigate NGFW to V7.6.9 or later following the secure update recommendation procedure. Contact customer support to receive detailed information The following versions of Siemens RUGGEDCOM APE1808 are affected: RUGGEDCOM APE1808…
Read more of the source summary
vers:all/* (CVE-2026-106175) CVSS Vendor Equipment v3 2.3 Siemens RUGGEDCOM APE1808 1 Vulnerability Double Free Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities CVE-2026-106175 A Double Free vulnerability [CWE-415] in FortiOS, FortiProxy and FortiSwitch may allow a local authenticated attacker to crash the newcli daemon via crafted CLI commands. Read More 1 Affected Product RUGGEDCOM APE1808 with Fortinet NGFW Product Status: known_affected Remediations Vendor fix Update Fortigate NGFW to V7.6.9 or later following the secure update recommendation procedure. Contact customer support to receive detailed information Additional Metrics Relevant CWE: CWE-415 Double Free…
View CSAF Summary Graphics Designer of SIMATIC WinCC before V8.2 contains an implicit active content execution vulnerability upon opening files, which could allow an attacker to cause arbitrary code execution on the device. Siemens is preparing fixes and recommends specific mitigations for products where fixes are not or not yet available. The following versions of Siemens SIMATIC WinCC are affected: SIMATIC WinCC…
Read more of the source summary
V7.5 vers:all/* (CVE-2026-59082) SIMATIC WinCC V8.0 vers:all/* (CVE-2026-59082) SIMATIC WinCC V8.1 vers:all/* (CVE-2026-59082) CVSS Vendor Equipment v3 7.8 Siemens SIMATIC WinCC V7.5 1 Vulnerability Insufficient UI Warning of Dangerous Operations Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities CVE-2026-59082 Affected devices implicitly execute active content when opening files. This could allow an attacker to make the user execute arbitrary code on the device. Read More 3 Affected Products SIMATIC WinCC V7.5 Product Status: known_affected Remediations Mitigation The affected product may be operated only by personnel qualified for the specific task in accordance…
CISA has added two new vulnerabilities to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-114713 UnrealIRCd Improper Neutralization of Delimiters Vulnerability CVE-2026-123039 Check Point Multiple Products Incorrect Permission Assignment for Critical Resource Vulnerability These types of vulnerabilities are a frequent attack vector for malicious cyber actors and…
Read more of the source summary
pose significant risks to the federal enterprise. Binding Operational Directive (BOD) 26-04: Prioritizing Security Updates Based on Risk establishes vulnerability management requirements for Federal Civilian Executive Branch (FCEB) agencies. BOD 26-04 reinforces the importance of the KEV Catalog and requires federal agencies to prioritize rapid remediation of high-risk vulnerabilities, specifically those identified by Common Vulnerabilities and Exposures (CVEs) listed in CISA’s KEV Catalog on publicly exposed assets that grant total control of the asset post-exploitation, while deferring action for lower-risk vulnerabilities. BOD 26-04 further establishes basic expectations for when agencies must check whether threat actors compromised the system before the patch was…
View CSAF Summary On October 21, 2026, the PHP project and security researchers disclosed two critical, unauthenticated remote code execution vulnerabilities in the core PHP language runtime known as "php2shell" (tracked as CVE-2026-109618 and CVE-2026-109619). This advisory covers the status of impact of various Siemens software products. As a general security measure, Siemens strongly recommends to protect network…
Read more of the source summary
access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines, and to follow the recommendations in the product manuals. Siemens is actively monitoring the situation and assessing the implications of these vulnerabilities on our portfolio. Because this evaluation is ongoing, our findings are subject to change as new technical details and vendor updates emerge. We will publish updated findings, guidance, and remediation recommendations as soon as they become available. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fixes and recommends…
View CSAF Summary Siemens is currently assessing the impact of Node2Shell (CVE-2026-111497) on Industrial Edge. Please check your Industrial Edge Management (IEM) setup: - No Management Applications installed: No action is required. Although the affected Brotli library is included in the IEM software stack, the affected functionality is not used or exposed. The same applies to IEDK. - Management Applications…
Read more of the source summary
installed: Follow the specific mitigations until a fix is available. - Device Applications installed: Follow the specific mitigations until a fix is available. For Siemens-managed services, Industrial Edge Hub and Industrial Edge Management Cloud, appropriate Firewall/WAF protection has already been implemented. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fixes and recommends specific mitigations for products where fixes are not or not yet available. The following versions of Siemens Industrial Edge Management are affected: Cloud Connector Configurator vers:intdot/
View CSAF Summary Palo Alto Networks has published information on a vulnerability in PAN-OS related to the Node2Shell vulnerability. This advisory lists the related Siemens Industrial products affected by this vulnerability. Customers are advised to consult and implement the workarounds provided in Palo Alto Networks' upstream security notifications. The following versions of Siemens RUGGEDCOM APE1808 are affected:…
Read more of the source summary
RUGGEDCOM APE1808 vers:all/* (CVE-2026-111497) CVSS Vendor Equipment v3 9.8 Siemens RUGGEDCOM APE1808 1 Vulnerability Out-of-bounds Write Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities CVE-2026-111497 A buffer overflow vulnerability in the Brotli decoder (c/dec/decode.c) in Google Brotli versions 1.0.3 through 1.2.0 on all platforms allows a remote unauthenticated attacker to corrupt adjacent decoder state memory, disclose sensitive memory contents, cause a denial of service, or potentially execute arbitrary code using a crafted Brotli-compressed stream. Users need to update any Brotli libraries or binaries between 1.0.3 through 1.2.0 to the latest available…
View CSAF Summary On October 21, 2026, the Node.js project released security updates addressing a critical vulnerability in the Brotli decoder bundled with Node.js, commonly referred to as "Node2Shell" (tracked as CVE-2026-111497). The vulnerability is an out-of-bounds write that could allow a remote attacker to cause memory corruption and potentially execute arbitrary code. This advisory covers the status of impact…
Read more of the source summary
of various Siemens software products. Siemens has released new versions for the affected products and recommends to update to the latest versions. The following versions of Siemens Desigo, Gridscale are affected: Desigo CC family V8 vers:all/* (CVE-2026-111497) Desigo CC family V9 vers:all/* (CVE-2026-111497) Gridscale X DSA vers:intdot/>=5.3|
View CSAF Summary Palo Alto Networks has published information on vulnerabilities in PAN-OS related to PHP2Shell vulnerabilities. This advisory lists the related Siemens Industrial products affected by these vulnerabilities. Customers are advised to consult and implement the workarounds provided in Palo Alto Networks' upstream security notifications. The following versions of Siemens RUGGEDCOM APE1808 are affected:…
Read more of the source summary
RUGGEDCOM APE1808 vers:all/* (CVE-2026-109618, CVE-2026-109619) CVSS Vendor Equipment v3 9.8 Siemens RUGGEDCOM APE1808 1 Vulnerability Use After Free Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities Expand All + CVE-2026-109618 PHP uses longjmp() for out-of-memory (OOM) errors to exit the current context and abort handling of the request. Some contexts may not properly account for this scenario and leave request memory in an uninitialized state before performing an allocation. The subsequent request cleanup procedure may read or branch on this memory. Multiple OOM strategies can consistently trigger this condition and lead to remote code execution (RCE). Read…